指南与共识心血管USMR

慢性主动脉瓣反流的超声心动图评估:与心脏磁共振的比较及对指南推荐的意义

Echocardiographic Evaluation of Chronic Aortic Regurgitation: Comparison With Cardiac Magnetic Resonance and Implications for Guideline Recommendations.
指南 / 共识 · JACC Cardiovasc Imaging · 2024-11-13

研究纳入81例主动脉瓣反流患者,在4小时内行超声心动图和心脏磁共振,按美国超声心动图学会(ASE)指南分级并以磁共振为参考标准,评估超声诊断严重反流的准确性并探索简化方法。结果显示ASE指南识别严重反流的AUC为0.9(敏感度82.4%、特异度96.9%),采用缩流颈宽度≥0.5 cm联合左室舒张末期容积指数≥82 mL/m2的简化方法可可靠识别显著反流。

要点

  • ASE指南分级识别磁共振定义的严重主动脉瓣反流AUC为0.9,敏感度82.4%、特异度96.9%。
  • 缩流颈宽度、射流宽度和左室舒张末期容积指数与磁共振对照准确性最高(AUC 0.86-0.89)。
  • 不依赖反流容积定量时,缩流颈宽度≥0.5 cm联合左室舒张末期容积指数≥82 mL/m2识别≥中重度反流的阳性预测值95.5%、阴性预测值87.5%。

核心结论

  • ASE指南在识别显著主动脉瓣反流方面表现很好;采用缩流颈宽度和左室容积的简化方法可可靠识别显著反流;需在更大队列中并与临床结局对照进一步验证。

研究设计与样本

  • 研究论文;81例主动脉瓣反流患者,超声心动图与心脏磁共振检查间隔小于4小时,以心脏磁共振为参考标准,按ASE指南分级。

诊断标准与关键数值

  • 超声ASE分级识别磁共振定义的严重反流的AUC为0.9(敏感度82.4%、特异度96.9%);超声参数与磁共振对照准确性最高者为缩流颈宽度、射流宽度和左室舒张末期容积指数(AUC 0.86-0.89),压力减半时间准确性最低;不依赖反流容积定量时,缩流颈宽度≥0.5 cm且左室舒张末期容积指数≥82 mL/m2识别磁共振≥中重度反流的阳性预测值95.5%、阴性预测值87.5%(AUC 0.89)。

临床应用与阅片要点

  • 日常阅片可测量缩流颈宽度和左室舒张末期容积指数,用简化组合识别显著主动脉瓣反流;反流容积定量用脉冲多普勒法(二尖瓣环与右室流出道对比左室流出道)可行性>88%,近端等速表面积法可行性低(37%)。

局限性

  • 原文指出需在更大队列中并与临床结局对照进一步验证该研究结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Guidelines for echocardiographic evaluation of aortic regurgitation (AR) have not been validated against an independent quantitative standard.

OBJECTIVES: The aim of this study was to evaluate the accuracy of the ASE (American Society of Echocardiography) AR guidelines against cardiac magnetic resonance (CMR) and to develop simplified approaches for detection of significant AR.

METHODS: Patients with AR underwent echocardiography and CMR <4 hours apart. AR severity was graded according to ASE guidelines. Quantitation of regurgitant volume (RegV) was performed with pulsed Doppler at the mitral annulus and right ventricular outflow compared with left ventricular (LV) outflow, and with proximal isovelocity surface area.

RESULTS: The authors studied 81 patients; median age was 52 years, and 58% had a bicuspid aortic valve. According to echo, 35 (43%) patients had mild AR, 18 (22%) moderate, 12 (15%) moderate to severe, and 16 (20%) had severe AR. The area under the curve (AUC) for detection of severe AR by CMR using ASE grading was 0.9 (82.4% sensitivity and 96.9% specificity). Feasibility of RegV quantitation was >88% using either echo volumetric method, and it was low for proximal isovelocity surface area (37%). The highest accuracy for echo parameters against CMR was seen with vena contracta width, jet width, and LV end-diastolic volume index (AUC: 0.86-0.89); pressure half-time had the lowest accuracy. Without RegV quantitation, a vena contracta width ≥0.5 cm and indexed LV end-diastolic volume ≥82 mL/m2 had 95.5% positive predictive value and 87.5% negative predictive value for identifying ≥moderate to severe AR by CMR (AUC: 0.89).

CONCLUSIONS: The ASE guidelines display very good performance in identifying significant AR. A simplified approach using vena contracta width and LV volumes can be used to reliably identify significant AR. Further validation of the findings in larger cohorts and against clinical outcomes is needed.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Attar R, Malahfji M, Angulo C, et al. Echocardiographic Evaluation of Chronic Aortic Regurgitation: Comparison With Cardiac Magnetic Resonance and Implications for Guideline Recommendations. JACC Cardiovasc Imaging. 2024. PMID: 39545892. doi:10.1016/j.jcmg.2024.08.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。