指南与共识腹部泌尿生殖技术与安全MRUS

结构化磁共振成像与肛管内超声肛瘘报告模板(SMART):一项跨学科德尔菲共识

Structured magnetic resonance imaging and endoanal ultrasound anal fistulas reporting template (SMART): An interdisciplinary Delphi consensus.
指南 / 共识 · World J Gastrointest Surg · 2024-01-01

该改良德尔菲研究基于RAND-UCLA适宜性方法,于2023年5月至8月由多学科专家组对14条陈述进行最多三轮匿名投票,共识定义为≥80%专家评分≥8分。三轮后14条中12条达成共识(85.7%),据此确定肛瘘MRI与肛管内超声报告应包含的六项特征:原发瘘管、继发延伸、内口、集合的存在、共存病变和括约肌形态,形成SMART结构化模板。

要点

  • SMART模板要求肛瘘影像报告包含六项特征:原发瘘管、继发延伸、内口、集合、共存病变和括约肌形态。
  • 共识采用0-10评分,≥80%专家评分≥8分定义为达成共识,最终14条中12条达成共识(85.7%)。
  • 模板旨在以简单、系统、省时的方式标准化肛瘘影像报告,提供转诊医师所需的最小数据集和可视化示意图。

核心结论

  • 开发了结构化模板SMART,用于以简单、系统、省时的方式标准化肛瘘的影像报告,提供转诊医师所需的最小数据集信息和可视化示意图。

研究设计与样本

  • 改良德尔菲调查,基于RAND-UCLA适宜性方法构建共识,于2023年5月至8月进行;数据库来自系统文献综述选出的151篇文章,用于生成循证陈述;14个问题由跨学科多学科专家组匿名投票,最多三轮迭代;11个科学学会(3个放射学会和8个外科学会)支持该研究;专家包括69名结直肠外科医生、23名放射科医生、2名解剖学家和1名胃肠病学家。

诊断标准与关键数值

  • 共识定义为专家组中≥80%的成员评分≥8分(0-10数字量表);三轮投票后,专家对14条陈述中的12条达成共识(85.7%);基于德尔菲结果,SMART纳入肛瘘的以下六项特征:原发瘘管、继发延伸、内口、集合的存在、共存病变和括约肌形态。

临床应用与阅片要点

  • SMART模板可用于标准化肛瘘的MRI和肛管内超声报告,以简单、系统、省时的方式提供转诊医师所需的最小数据集信息和可视化示意图。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: There is still considerable heterogeneity regarding which features of cryptoglandular anal fistula on magnetic resonance imaging (MRI) and endoanal ultrasound (EAUS) are relevant to surgical decision-making. As a consequence, the quality and completeness of the report are highly dependent on the training and experience of the examiners.

AIM: To develop a structured MRI and EAUS template (SMART) reporting the minimum dataset of information for the treatment of anal fistulas.

METHODS: This modified Delphi survey based on the RAND-UCLA appropriateness for consensus-building was conducted between May and August 2023. One hundred and fifty-one articles selected from a systematic review of the literature formed the database to generate the evidence-based statements for the Delphi study. Fourteen questions were anonymously voted by an interdisciplinary multidisciplinary group for a maximum of three iterative rounds. The degree of agreement was scored on a numeric 0-10 scale. Group consensus was defined as a score ≥ 8 for ≥ 80% of the panelists.

RESULTS: Eleven scientific societies (3 radiological and 8 surgical) endorsed the study. After three rounds of voting, the experts (69 colorectal surgeons, 23 radiologists, 2 anatomists, and 1 gastroenterologist) achieved consensus for 12 of 14 statements (85.7%). Based on the results of the Delphi process, the six following features of anal fistulas were included in the SMART: Primary tract, secondary extension, internal opening, presence of collection, coexisting lesions, and sphincters morphology.

CONCLUSION: A structured template, SMART, was developed to standardize imaging reporting of fistula-in-ano in a simple, systematic, time-efficient way, providing the minimum dataset of information and visual diagram useful to referring physicians.

来源:World J Gastrointest Surg,查看原文。版权归原作者所有。

引用

  1. Sudoł-Szopińska I, Garg P, Mellgren A, et al. Structured magnetic resonance imaging and endoanal ultrasound anal fistulas reporting template (SMART): An interdisciplinary Delphi consensus. World J Gastrointest Surg. 2024. PMID: 39575264. doi:10.4240/wjgs.v16.i10.3288

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。