髂静脉阻塞:直接多排探测器CT静脉造影与双功能超声的准确性
本研究以血管内超声为参考标准,评估直接CT静脉造影(DCTV)和双功能超声(DUS)在94例重度慢性静脉疾病(CEAP C3-6)患者中识别髂静脉阻塞的准确性。DCTV在各级阻塞中的敏感度和特异度均达95%以上,DUS为63.9%-70%和65%-85%,DCTV的观察者间一致性为0.96,DUS为0.73。作者认为DUS可作为识别显著髂静脉阻塞的合理初始影像方法,DCTV能为治疗规划提供准确可重复的影像信息。
要点
- DCTV在髂静脉阻塞各级(1-3级)的敏感度和特异度均达95%以上,观察者间一致性κ=0.96。
- DUS对各级髂静脉阻塞的敏感度为63.9%-70%、特异度为65%-85%,观察者间一致性κ=0.73。
- 作者认为DUS可作为识别显著髂静脉阻塞的合理初始影像方法,DCTV可为治疗规划提供准确可重复的评估。
核心结论
- DUS是识别显著髂静脉阻塞的合理初始影像方法;DCTV能为治疗规划提供准确可重复的影像信息,包括阻塞部位、形态和程度的准确评估。
研究设计与样本
- 以血管内超声(IVUS)为参考标准,纳入94例晚期慢性静脉疾病(CEAP C3-6)患者,均行DCTV、静脉双功能超声和IVUS检查。
诊断标准与关键数值
- 阻塞程度分为三级:1级为0%-49%,2级为50%-79%,3级为80%及以上。
- DCTV诊断阻塞的敏感度、特异度分别为:1级96%、95%;2级100%、100%;3级100%、100%。
- DUS诊断阻塞的敏感度、特异度分别为:1级63.9%、65%;2级68%、82%;3级70%、85%。
- DUS总体观察者间一致性为0.73(95%CI 0.70-0.79),DCTV为0.96(95%CI 0.91-0.97)。
- IVUS在94例中识别出55例(58.5%)髂静脉阻塞,其中1级占25.5%、2级占27.3%、3级占47.3%。
临床应用与阅片要点
- 作者认为DUS可作为识别显著髂静脉阻塞的合理初始影像方法。
- 作者认为DCTV可为髂静脉阻塞治疗规划提供准确可重复的影像信息,包括阻塞部位、形态和程度。
- 作者指出DCTV可替代使用较少对比剂的间接CT静脉造影,并获得准确诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the accuracy of direct computed tomographic venography (DCTV) and duplex ultrasound (DUS) in the identification of iliac vein obstruction in highly symptomatic patients with severe chronic venous disease (CVD) compared with intravascular ultrasound (IVUS).
METHODS: This study involved patients who had advanced CVD (CEAP C3-6). All patients underwent DCTV, venous duplex scanning, and IVUS. The presence of iliac vein obstruction was detected, and degree of obstruction was classified into three grades (grade I, 0%-49%; grade II, 50%-79%; and grade III, 80% or greater). The sensitivity, specificity, PPV, NPV, and accuracy were calculated for each modality compared with IVUS. Inter-observer agreement was assessed using the κ coefficient.
RESULTS: Of the 94 patients with CVD, IVUS identified iliac vein obstruction in 55 (58.5%) patients (25.5% was grade 1, 27.3% was grade 2, 47.3% was grade 3). The sensitivity, specificity of DCTV in diagnosing obstruction were 96%, 95% in grade 1; 100%, 100% grade 2; 100%, 100% in grade 3, respectively. The sensitivity, specificity of DUS were 63.9%, 65% in grade 1; 68%, 82% in grade 2, and 70%, 85% in grade 3, respectively. The overall agreement of DUS was 0.73 (95% CI, 0.70-0.79), and DCTV was 0.96 (95% CI, 0.91-0.97).
CONCLUSIONS: DUS is a reasonable initial imaging modality for the identification of significant iliac vein obstruction. DCTV provides an accurate reproducible imaging for accurate estimation needed for treatment planning.
ADVANCES IN KNOWLEDGE: DCTV provides accurate reproducible radiological information required for treatment planning of patients with iliac vein obstruction including accurate assessment of site of obstruction, its morphology, and degree of obstruction and it can replace the use of indirect CT venography using smaller amount of contrast media with accurate diagnosis.
引用
- Abdalla Ahmed S, Elbadawy A, Khalaf LMR, et al. Iliac vein obstruction: accuracy of direct multidetector computed tomographic venography and duplex ultrasound. Br J Radiol. 2025. PMID: 39400315. doi:10.1093/bjr/tqae194