热释光剂量计测量的医护人员辐射剂量
该回顾性研究分析了单一机构2018—2022年94名放射相关人员的职业辐射剂量,年均有效剂量男性0.58—0.72 mSv、女性0.68—0.85 mSv,均远低于年剂量限值;除护士外,COVID-19期间与之前的平均年有效剂量相似。
要点
- 所有放射技师、86%护士和69%医师的年均有效剂量低于0.99 mSv。
- 核医学技师的平均有效剂量相对高于其他放射职业人员。
- 除护士外,COVID-19期间与之前的平均年有效剂量相似。
核心结论
- 2018—2022年放射工作人员的年均有效剂量远低于年剂量限值;核医学技师的平均有效剂量相对较高;尽管COVID-19期间工作量因政府政策降低,医护人员辐射剂量与大流行前相似。
研究设计与样本
- 单机构回顾性分析,纳入诊断放射学和核医学部门94名放射工作人员(放射技师、核医学技师、医师、护士),采用热释光剂量计测量5年(2018—2022年)职业辐射剂量。
诊断标准与关键数值
- 年均有效剂量男性为0.58—0.72 mSv,女性为0.68—0.85 mSv。
- 所有放射技师、86%护士和69%医师的年均有效剂量低于0.99 mSv。
- 护士在COVID-19前的平均年有效剂量显著低于COVID-19期间(P<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate radiation dose among physicians, nurses, nuclear medicine (NM) technicians, and radiographers at a single institution and to compare the difference in the measured dose during COVID-19 with other periods.
MATERIALS AND METHODS: A retrospective analysis of the occupational radiation doses received by all workers in diagnostic radiography and NM departments at a single institution during a 5-year period (2018-2022) was performed. Dose measurements were recorded for 94 radiology personnel: radiographers, NM technicians, physicians, and nurses. In addition to descriptive statistics, the Mann-Whitney U-test was used to compare the average annual effective dose between male and female workers and between the periods before and during COVID-19. Kruskal-Wallis test was used to compare effective radiation doses from different quadrants.
RESULTS: The annual average effective doses were found to be between 0.58 and 0.72 mSv for males and 0.68 and 0.85 mSv for females. All radiographers, 86% of nurses, and 69% of physicians have received annual average effective doses below 0.99 mSv. The average annual effective doses for all radiation workers were similar in the period before COVID-19 when compared to the period during COVID-19 except for nurses who had significantly lower (P<0.05) doses before COVID-19.
CONCLUSION: The average annual effective doses of radiation workers during 2018-2022 were well below the annual dose limit. A relatively higher average effective dose was received among NM technicians compared with other radiation occupational workers. While the caseload during the COVID-19 pandemic was lower due to government policies, the radiation dose to healthcare workers during the pandemic was similar to that before the pandemic.
引用
- Alakhras M, Al-Mousa DS, Al Mohammad B, et al. Radiation dose to health care workers measured by thermoluminescent dosimetry. Clin Radiol. 2024. PMID: 39462717. doi:10.1016/j.crad.2024.09.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。