0至4岁儿童松果体ADC值:正常参考数据及其在三侧性视网膜母细胞瘤鉴别诊断中的价值
本研究在三级儿童医院回顾性纳入64例0至4岁松果体正常患儿,建立松果体平均ADC参考值(均高于1000×10⁻⁶ mm²/s),并发现3例三侧性视网膜母细胞瘤患儿松果体ADC值约为800×10⁻⁶ mm²/s,提示DWI/ADC有助于识别小病灶。
要点
- 0至4岁儿童正常松果体平均ADC值均高于1000×10⁻⁶ mm²/s。
- 三侧性视网膜母细胞瘤患儿松果体ADC值约为800×10⁻⁶ mm²/s。
- 松果体ADC值男女相同,体积随年龄增长呈增大趋势。
核心结论
- 儿童松果体平均ADC参考值均高于1000×10⁻⁶ mm²/s,三侧性视网膜母细胞瘤的ADC值分布与正常值显著不同,DWI/ADC可能有助于识别儿童眼部病变中的小三侧性视网膜母细胞瘤。
研究设计与样本
- 回顾性研究,在三级儿童医院收集2017年至2024年间64例松果体正常、临床指征与松果体无关的MRI检查患儿,分为5个年龄组(0至4岁),用椭球公式计算腺体大小、ROI/直方图分析计算平均ADC值,并在3例三侧性视网膜母细胞瘤(10至20个月)中检验所建数值。
关键影像表现/征象
- 正常松果体平均ADC值均高于1000×10⁻⁶ mm²/s。
- 三侧性视网膜母细胞瘤患儿松果体ADC值约为800×10⁻⁶ mm²/s。
- 松果体体积随年龄增长呈增大趋势。
诊断标准与关键数值
- 正常松果体平均ADC参考值高于1000×10⁻⁶ mm²/s(0至4岁儿童,ROI/直方图分析)。
- 三侧性视网膜母细胞瘤松果体平均ADC值约为800×10⁻⁶ mm²/s(3例,10至20个月)。
临床应用与阅片要点
- 作者认为DWI/ADC可能有助于在儿童眼部病变中识别小三侧性视网膜母细胞瘤。
- 原文指出肿瘤小于10-15 mm时松果体受累的鉴别诊断具有挑战性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Normative ADC values of the pineal gland in young children are currently lacking, however, these are potentially useful in the differential diagnosis of pineal involvement in trilateral retinoblastoma, which is challenging when the size of the tumor is less than 10-15 mm. The main objective of this study was to establish ADC reference values of the normal pineal gland in a large cohort of children between 0 and 4 years.
METHODS: This retrospective study was conducted in a tertiary pediatric hospital. We collected 64 patients with normal MRI examination (between 2017 and 2024) and clinical indication unrelated to the pineal gland, and divided them into 5 age groups (0 to 4 years). Gland size and mean ADC values were calculated, using the ellipsoid formula and ROI/histogram analysis, respectively. The established values were tested in three cases of trilateral retinoblastoma (10 to 20 months).
RESULTS: Mean ADC values were always above 1000 × 10- 6 mm2/s, while in patients with trilateral retinoblastoma they were around 800 × 10- 6 mm2/s. Pineal ADC values were identical in both genders. The volume of the pineal gland showed a tendency to increase with age.
CONCLUSIONS: We present ADC reference data for the pineal gland in children under 4 years of age. The distribution of mean ADC values of trilateral retinoblastoma was significantly different from the normative values, hence, the use DWI/ADC may help to identify small trilateral retinoblastoma in children with ocular pathology.
引用
- Freire I, Falsitta LV, Sharma C, et al. Pineal gland ADC values in children aged 0 to 4 years: normative data and usefulness in the differential diagnosis with trilateral retinoblastoma. Neuroradiology. 2024. PMID: 39365330. doi:10.1007/s00234-024-03479-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。