前瞻性纳入38例患儿,采用超低活度18F-FDG(0.37 MBq/kg)行全身动态PET/CT,比较不同采集时间重建图像质量。8分钟采集(G8)图像质量主观评分4.25±0.30,全部病灶可检出,可满足诊断要求,有效剂量仅0.58±0.19 mSv。
要点
- 超低活度0.37 MBq/kg下,8分钟采集图像质量可满足诊断要求,全部病灶可检出。
- G1-G7主观评分均低于3分,G8起图像质量达标,G8前SNR、TBR、CNR与对照组有显著差异。
- 患儿有效剂量仅0.58±0.19 mSv,体现超低剂量PET/CT在儿童中的可行性。
核心结论
- 超低活度儿童全身18F-FDG PET/CT采用8分钟采集的图像质量可满足诊断要求。
研究设计与样本
- 前瞻性纳入38例患儿,行超低活度(0.37 MBq/kg)全身动态PET/CT,采集60分钟列表模式原始数据,重建为50-51、50-52、50-53、50-54、50-55、50-58、50-60和45-60分钟数据,分别记为G1、G2、G3、G4、G5、G8、G10和G15。
诊断标准与关键数值
- 主观图像质量采用Likert量表评分,G1-G15平均分分别为1.10±0.20、2.03±0.26、2.66±0.35、3.00±0.27、3.32±0.34、4.25±0.30、4.49±0.36和4.70±0.37;G8起全部病灶可检出;G8前背景SNR、TBR和CNR与对照组有显著差异(均P<0.05);读者间一致性kappa=0.878(95%CI 0.845-0.910)。
临床应用与阅片要点
- 儿童超低活度18F-FDG全身PET/CT可采用8分钟采集重建图像,图像质量满足诊断要求,且有效剂量仅0.58±0.19 mSv。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the feasibility of paediatric 18F-FDG total-body PET/CT imaging with an ultra-low activity and explore an optimized acquisition time range.
METHODS: A total of 38 paediatric patients were prospectively enrolled and underwent dynamic total-body PET/CT imaging using ultra-low 18F-FDG activity (0.37 MBq/kg). The 60-minute list-mode raw data were acquired and then reconstructed as static PET images by using 50-51, 50-52, 50-53, 50-54, 50-55, 50-58, 50-60, and 45-60 minutes data, which were noted as G1, G2, G3, G4, G5, G8, G10, and G15, respectively. Image qualities were subjectively evaluated using the Likert scale and were objectively evaluated by the quantitative metrics including standard uptake value (SUV), signal-to-noise ratio (SNR), target-to-background ratio (TBR), and contrast-to-noise ratio (CNR).
RESULTS: The injected activity of FDG was 13.38 ± 5.68 MBq (4.40-28.16 MBq) and produced 0.58 ± 0.19 mSv (0.29-1.04 mSv) of effective dose. The inter-reader agreement of subjective image quality was excellent (kappa = 0.878; 95% CI, 0.845-0.910). The average scores of image quality for G1-G15 were 1.10 ± 0.20, 2.03 ± 0.26, 2.66 ± 0.35, 3.00 ± 0.27, 3.32 ± 0.34, 4.25 ± 0.30, 4.49 ± 0.36, and 4.70 ± 0.37, respectively. All image scores are above 3, and all lesions are detectable starting from G8. SNRs of backgrounds, TBRs, and CNRs were significant differences from the control group before G8 (all P < 0.05).
CONCLUSION: The image quality of the 8 min acquisition for paediatric 18F-FDG total-body PET/CT with an ultra-low activity could meet the diagnostic requirements.
ADVANCES IN KNOWLEDGE: This study confirms the feasibility of ultra-low dose PET imaging in children, and its methods and findings may guide clinical practice. Paediatric patients will benefit from reduced radiation doses.