文献速递外周血管头颈技术与安全US

基于射频数据的血管硬度定量分析与动态向量血流成像评估2型糖尿病患者颈动脉结构与功能改变

Quantitative Analysis on Vessel Stiffness and Vector Flow Imaging in the Assessment of Carotid Artery Structural and Functional Changes in Patients With Type 2 Diabetes.
PubMed 文献 · Ultrasound Med Biol · 2024-10-07

前瞻性研究纳入275例受试者(对照组50例、颈动脉内中膜厚度正常的2型糖尿病108例、内中膜增厚的2型糖尿病117例),采用R-QVS测量颈动脉远端收缩期直径、位移、硬度系数和脉搏波传导速度,VFI测量壁面剪切应力及最大瞬时流速。结果显示各组间上述参数均有显著差异,硬度系数、脉搏波传导速度、最大壁面剪切应力的AUC分别为0.83、0.88、0.86;R-QVS联合VFI有助于2型糖尿病颈动脉结构与功能改变的早期评估。

要点

  • 硬度系数、脉搏波传导速度和最大壁面剪切应力评估2型糖尿病颈动脉改变的AUC分别为0.83、0.88和0.86。
  • 颈动脉内中膜厚度正常的2型糖尿病患者已出现功能改变,且较形态学改变更明显。
  • 位移、硬度系数、脉搏波传导速度、最大壁面剪切应力和平均壁面剪切应力是颈动脉内中膜厚度的影响因素。

核心结论

  • R-QVS与VFI技术有助于早期评估2型糖尿病患者颈动脉的结构与功能改变。
  • 与对照组相比,颈动脉内中膜厚度正常的2型糖尿病患者已表现出较形态学改变更明显的功能改变。
  • 这些方法敏感度、可重复性和详细评估能力提高,使其在2型糖尿病心血管风险早期检测和干预中有价值。

研究设计与样本

  • 前瞻性研究,2022年10月至2024年4月连续纳入275例受试者。
  • 对照组50例志愿者,2型糖尿病且颈动脉内中膜厚度正常者108例,2型糖尿病且颈动脉内中膜增厚者117例。
  • 采用实时内中膜厚度技术测量颈动脉内中膜厚度,R-QVS测量颈动脉远端收缩期直径、位移、硬度系数和脉搏波传导速度。
  • VFI测量血管壁最大壁面剪切应力、平均壁面剪切应力和最大瞬时流速。

关键影像表现/征象

  • 三组间颈动脉内中膜厚度、收缩期直径、位移、硬度系数、脉搏波传导速度、最大壁面剪切应力和最大瞬时流速差异均有统计学意义(均p<0.01)。

诊断标准与关键数值

  • 收缩期直径评估2型糖尿病颈动脉结构与功能改变的AUC为0.64。
  • 位移评估2型糖尿病颈动脉结构与功能改变的AUC为0.68。
  • 硬度系数评估2型糖尿病颈动脉结构与功能改变的AUC为0.83。
  • 脉搏波传导速度评估2型糖尿病颈动脉结构与功能改变的AUC为0.88。
  • 最大壁面剪切应力评估2型糖尿病颈动脉结构与功能改变的AUC为0.86,最大瞬时流速的AUC为0.82。

临床应用与阅片要点

  • 多因素线性回归显示位移、硬度系数、脉搏波传导速度、最大壁面剪切应力和平均壁面剪切应力是2型糖尿病患者颈动脉内中膜厚度的影响因素(β值分别为-0.406、0.515、0.564、-0.472和-0.438,均p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the value of RF-data-based quantitative analysis on vessel stiffness (R-QVS) combined with dynamic vector flow imaging (VFI) in evaluating structural and functional changes in the carotid arteries of patients with type 2 diabetes mellitus (T2DM).

METHODS: A prospective study was conducted between October 2022 and April 2024, including 275 consecutive subjects (50 volunteers as controls, 108 patients with T2DM and normal carotid intima-media thickness (CIMT), and 117 patients with T2DM and thickened CIMT). Carotid intima-media thickness (IMT) was measured using real-time intima-media thickness (RIMT) technology, while R-QVS was employed to measure the systolic diameter (Diam), displacement (Dist), hardness coefficient (HC), and pulse wave velocity (PWV) of the distal segment of the carotid artery. VFI was used to measure the maximum wall shear stress (WSSmax), mean wall shear stress (WSSmean), and maximum instantaneous velocity (Vmax) of the vessel wall. Differences in ultrasound parameters among the three groups were compared, and receiver operating characteristic (ROC) curves were plotted to calculate the area under the curve (AUC), evaluating the efficacy of these parameters in assessing structural and functional changes in the carotid arteries of patients with T2DM.

RESULTS: There were statistically significant differences in carotid IMT, Diam, Dist, HC, PWV, WSSmax, and Vmax among the three groups (all p < 0.01). The AUCs for evaluating structural and functional changes in the carotid arteries of patients with T2DM using carotid ultrasound parameters Diam, Dist, HC, PWV, WSSmax, and Vmax were 0.64, 0.68, 0.83, 0.88, 0.86, and 0.82, respectively. Multiple linear regression analysis identified Dist., HC, PWV, WSSmax, and WSSmean as influencing factors for CIMT in T2DM patients (with β values of -0.406, 0.515, 0.564, -0.472, and -0.438, respectively; all p < 0.05).

CONCLUSION: R-QVS and VFI techniques contribute to the early assessment of structural and functional changes in the carotid arteries of patients with type 2 diabetes mellitus. Compared with controls, T2DM patients exhibit more advanced functional changes than morphological changes despite normal CIMT. The enhanced sensitivity, reproducibility, and detailed assessment capabilities of these methods make them valuable tools in the early detection and intervention of cardiovascular risk in T2DM.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Chang C, Gan L, Liao X, et al. Quantitative Analysis on Vessel Stiffness and Vector Flow Imaging in the Assessment of Carotid Artery Structural and Functional Changes in Patients With Type 2 Diabetes. Ultrasound Med Biol. 2024. PMID: 39379234. doi:10.1016/j.ultrasmedbio.2024.09.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。