文献速递骨肌US

2017年EULAR-OMERACT超声滑膜炎评分系统的可靠性与可用性:培训与阅片练习结果

Reliability and Availability of the 2017 EULAR-OMERACT Scoring System for Ultrasound Synovitis Assessment: Results From a Training and Reading Exercise.
PubMed 文献 · J Ultrasound Med · 2024-10-18

本研究回顾性纳入2020年1月至2022年3月类风湿关节炎患者,由5名不同肌骨超声经验的放射科医生在标准化培训前后对灰阶和多普勒超声图像进行EULAR-OMERACT评分,评估评分系统的可靠性和可用性。结果显示评分者内和评分者间一致性良好至很好,培训后GSUS和PDUS评分之和与临床评分呈中度至高正相关,提示该评分系统是评估RA滑膜炎的可靠方法,并可能用于疾病评估和随访。

要点

  • EULAR-OMERACT评分系统在5名放射科医生中评分者内一致性良好:GSUS κ 0.72-0.94,PDUS κ 0.81-0.97。
  • 专家间评分者间一致性良好至很好:GSUS κ 0.76-0.94,PDUS κ 0.80-0.96。
  • 培训后GSUS与PDUS评分之和与DAS28-CRP临床评分呈中度至高正相关(GSUS ρ 0.58-0.79,PDUS ρ 0.57-0.70)。

核心结论

  • EULAR-OMERACT评分系统是评估RA滑膜炎的可靠方法,并显示出用于RA患者疾病评估和随访的潜力。

研究设计与样本

  • 回顾性研究,从2020年1月至2022年3月招募RA患者,5名不同肌骨超声经验的放射科医生参与阅片研究(R1-5)。

诊断标准与关键数值

  • EULAR-OMERACT评分系统采用0-3分半定量评分。
  • 评分者内一致性:GSUS κ 0.72-0.94,PDUS κ 0.81-0.97。
  • 评分者间一致性(专家间):GSUS κ 0.76-0.94,PDUS κ 0.80-0.96。
  • GSUS和PDUS评分之和与DAS28-CRP临床评分的相关性:GSUS ρ 0.58-0.79,PDUS ρ 0.57-0.70。

临床应用与阅片要点

  • 放射科医生可应用EULAR-OMERACT评分系统对RA患者的灰阶和多普勒超声图像进行半定量评分。
  • 标准化培训后评分与临床评分相关性良好,提示该评分系统可用于RA的疾病评估和随访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the availability and reliability of the European League Against Rheumatisms Outcome Measures in Rheumatology Synovitis (EULAR-OMERACT) scoring system among radiologists with different levels of musculoskeletal ultrasound (US) experience in assessing synovitis in patients with rheumatoid arthritis (RA).

METHOD: The patients with RA were retrospectively recruited from January 2020 to March 2022. Five radiologists with different levels of US experience were recruited for the reader study (R1-5), which included two parts. The participating radiologists first read 120 gray-scale (GS) and 120 Doppler US images twice, before and after a standard training program. In the first part, they semi-quantitatively scored the images from 0 to 3 based on the EULAR-OMERACT scoring system. In the second part, they read and scored 165 paired GS and Doppler images two times in 1 month using the EULAR-OMERACT scoring system. The correlation between the sum of the GSUS and power Doppler US (PDUS) image scores and the clinical scores was assessed.

RESULT: The intra-rater agreement of the five radiologists was good for the EULAR-OMERACT scoring system, with κ ranging from 0.72 to 0.94 for GSUS and from 0.81 to 0.97 for PDUS. The inter-rater agreement among the experts was good to very good in the EULAR-OMERACT scoring system (κ: 0.76-0.94 for GSUS and 0.80-0.96 for PDUS). The sum of the GSUS and PDUS scores in the EULAR-OMERACT scoring system was moderate to highly positively correlated with the clinical scores (ρ of GSUS: 0.58-0.79, ρ of PDUS: 0.57-0.70 for disease activity score in 28 joints C-reactive protein) after training.

CONCLUSION: The EULAR-OMERACT scoring system is a reliable method for evaluating synovitis in RA and shows potential for disease assessment and follow-up in patients with RA.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhao C, Zhuang N, Zhang Y, et al. Reliability and Availability of the 2017 EULAR-OMERACT Scoring System for Ultrasound Synovitis Assessment: Results From a Training and Reading Exercise. J Ultrasound Med. 2024. PMID: 39422331. doi:10.1002/jum.16607

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。