文献速递骨肌神经技术与安全US

基于梯度光流的超声散斑追踪方法量化外周神经小纵向位移、剪切及纵向应变

Ultrasound Speckle Tracking Method Based on Gradient Optical Flow to Quantify Small Longitudinal Displacement, Shear and Longitudinal Strain in Peripheral Nerves.
PubMed 文献 · Ultrasound Med Biol · 2024-10-29

研究用7例解冻新鲜冷冻离体前臂验证基于梯度光流的超声散斑追踪法,以22 MHz高频线阵探头采集正中神经纵向运动,气泡标记作为手动测量参考。回退5帧时位移低估降至4%,离体模型最高剪切应变位于神经-组织界面;8名健康受试者肘伸展与肩前屈时正中神经平均位移3.3 ± 1.0 mm,组间信度ICC=0.87。方法可有效量化小纵向位移和剪切应变,但在测试位移范围内未能检测神经纵向应变。

要点

  • 回退5帧时位移低估降至4%,精度较高。
  • 离体前臂模型中最高剪切应变位于神经-组织界面。
  • 健康受试者正中神经平均位移3.3 ± 1.0 mm,ICC=0.87。

核心结论

  • 基于梯度光流的超声散斑追踪法可高效量化外周神经小纵向位移和剪切应变,精度和准确度高;但在测试位移范围内未能检测神经纵向应变。

研究设计与样本

  • 方法学研究,用7例解冻新鲜冷冻离体前臂验证,以22 MHz高频线阵探头采集正中神经纵向运动,气泡标记作为手动测量参考;另在8名健康受试者测试临床可行性。

关键影像表现/征象

  • 离体前臂模型中最高剪切应变位于神经-组织界面。
  • 健康受试者肘伸展与肩前屈时正中神经平均位移3.3 ± 1.0 mm。

诊断标准与关键数值

  • 回退5帧时位移低估降至4%。
  • 健康受试者正中神经位移测量组间信度ICC=0.87。

临床应用与阅片要点

  • 作者指出未来研究应探讨该方法对更小、更深神经的适用性及其在不同病理条件下的实用性。

局限性

  • 方法在测试位移范围内未能检测神经纵向应变。
  • 未来研究应探讨其对更小、更深神经的适用性及在不同病理条件下的实用性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to develop, validate and test the clinical feasibility of ultrasound (US) speckle tracking method based on gradient optical flow for quantifying small longitudinal displacements, shear and strain in peripheral nerves.

METHODS: The speckle tracking method was validated using seven thawed, fresh-frozen isolated cadaveric forearms. Longitudinal motion of the median nerve was captured using a high-frequency 22 MHz linear probe. An air bubble marker was inserted as a reference point for manual measurement comparison. The precision and accuracy of the method were assessed by comparing manual and automatic measurements. Clinical feasibility was tested on eight healthy subjects, measuring the longitudinal displacement of the median nerve during elbow extension and shoulder anteflexion.

RESULTS: The method demonstrated linearity, high precision and accuracy, particularly with a backtrace of five frames, reducing the displacement underestimation to 4%. In cadaveric models, the highest shear strain was observed at the nerve-tissue interfaces. In healthy subjects, the mean displacement of the median nerve was 3.3 ± 1.0 mm, with good inter-rater reliability (intraclass correlation coefficient = 0.87).

CONCLUSION: The US speckle tracking method based on gradient optical flow effectively quantifies small longitudinal displacements and shear strain in peripheral nerves, with high precision and accuracy. However, the method could not detect longitudinal strain in nerves within the range of tested displacements. Future studies should investigate its applicability to smaller and deeper nerves and its usefulness in different pathological conditions.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Snoj Ž, Omejec G, Javh J, et al. Ultrasound Speckle Tracking Method Based on Gradient Optical Flow to Quantify Small Longitudinal Displacement, Shear and Longitudinal Strain in Peripheral Nerves. Ultrasound Med Biol. 2024. PMID: 39477744. doi:10.1016/j.ultrasmedbio.2024.10.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。