文献速递骨肌US

高强度连续超声对健康参与者髌下脂肪垫硬度与滑动的影响:一项随机、单盲、安慰剂对照交叉试验

Effects of High-intensity Continuous Ultrasound on Infrapatellar Fat Pad Stiffness and Gliding in Healthy Participants: A Randomized, Single-blind, Placebo-controlled Crossover Trial.
PubMed 文献 · Ultrasound Med Biol · 2024-10-15

该单盲随机对照交叉试验纳入24名健康参与者,在膝关节分别施加高强度连续超声(HICUS)与安慰剂,比较髌下脂肪垫(IFP)硬度与滑动。结果显示HICUS在10度屈膝时降低IFP硬度、改善滑动,且效果持续至治疗后15分钟;120度屈膝时硬度无显著差异。作者认为HICUS是简单安全的干预,但需进一步在患者中评估疗效。

要点

  • HICUS(1 MHz、2.5 W/cm²、占空比100%、5分钟)在10度屈膝时降低IFP硬度,即刻与15分钟后均有效。
  • HICUS在10度和120度屈膝间测量的IFP滑动在治疗后即刻与15分钟后均显著改善。
  • 120度屈膝时IFP硬度在HICUS与安慰剂间无显著差异。

核心结论

  • HICUS是改善健康参与者IFP硬度与滑动的简单、安全干预,效果持续;需进一步研究评估其在患者中的疗效。

研究设计与样本

  • 单盲、随机、安慰剂对照交叉试验,纳入24名健康参与者,HICUS与安慰剂于不同日期施加于膝关节,使用配备涂布器和吸附式固定自动旋转照射功能的超声仪。

关键影像表现/征象

  • HICUS在10度屈膝时降低IFP硬度,治疗后即刻(T2)和15分钟后(T3)后测试均显示降低。
  • HICUS条件下IFP滑动存在显著交互作用,后测试显示T2和T3时滑动显著改善。
  • 120度屈膝时IFP硬度无显著差异。

诊断标准与关键数值

  • HICUS方案:1 MHz、2.5 W/cm²、占空比100%、5分钟。
  • IFP硬度与滑动在10度和120度屈膝时测量;滑动为10度与120度屈膝时髌腱-胫骨角度差值。
  • 测量时间点:治疗前(T1)、治疗后即刻(T2)、治疗后15分钟(T3)。

临床应用与阅片要点

  • 原文未据此给出临床推荐。

局限性

  • 作者指出需进一步研究评估HICUS在患者中的疗效。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Ultrasound therapy effectively treats a joint range of motion limitation and pain originating from soft tissue in knee osteoarthritis (OA). Few interventional studies have focused on the infrapatellar fat pad (IFP), and the effects of high-intensity continuous ultrasound (HICUS) on IFP stiffness and gliding have not been investigated. Therefore, we aimed to determine the effects of HICUS on IFP stiffness and gliding.

METHODS: This single-blind, randomized, controlled crossover study involved 24 healthy participants. The HICUS and placebo conditions were applied to the knee joint on 2 different days. HICUS was performed (1 MHz, 2.5 W/cm², duty cycle 100%, 5 min) using an ultrasound machine equipped with an applicator and adsorption-type fixed automatic rotation irradiation function. The main outcomes were IFP stiffness and gliding measured at 10 degrees and 120 degrees knee flexion. Gliding was measured as the difference between the patellar-tendon tibial angles at 10 degrees and 120 degrees knee flexion. Measurements were performed before (T1), immediately after (T2), and 15 min after (T3) treatment.

RESULTS: Two-way repeated measures analysis of variance showed a significant interaction of IFP stiffness at 10 degrees knee flexion; post-test results showed that HICUS decreased stiffness at T2 and T3. There was no significant difference at 120 degrees. A significant interaction of gliding was observed under the HICUS condition. Post-tests showed that HICUS significantly improved gliding at T2 and T3.

CONCLUSION: HICUS is a simple, safe intervention for improving IFP stiffness and gliding in healthy participants, with sustained effects. Further studies are needed to evaluate its efficacy in patients.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Ikeda N, Fukaya T, Sezaki Y, et al. Effects of High-intensity Continuous Ultrasound on Infrapatellar Fat Pad Stiffness and Gliding in Healthy Participants: A Randomized, Single-blind, Placebo-controlled Crossover Trial. Ultrasound Med Biol. 2024. PMID: 39414404. doi:10.1016/j.ultrasmedbio.2024.09.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。