可变螺距扫描下肢CT血管成像:降低对比剂剂量、提高图像质量与诊断准确率
前瞻性纳入80例行下肢CTA的患者,随机分为可变螺距(VHP)组40例与常规组40例,VHP组对比剂用量79.55±11.87 mL vs 常规组89.63±10.03 mL(降低12.7%,p<0.001),图像质量各项评分及胫前动脉、足背动脉的CT强化、SNR、CNR均优于常规组(均p<0.001)。以DSA为参考的72条动脉分析显示VHP组阳性预测值100% vs 76.19%(p=0.01)、准确率100% vs 84.38%(p=0.01)。
要点
- VHP组对比剂用量79.55±11.87 mL,较常规组89.63±10.03 mL降低12.7%(p<0.001)。
- VHP组图像质量各项评分均优于常规组(均p<0.05),膝下动脉强化与噪声指标更佳。
- 以DSA为参考,VHP组阳性预测值100% vs 76.19%、准确率100% vs 84.38%(均p=0.01)。
核心结论
- 采用VHP方案行下肢CTA较常规方案对比剂剂量降低12.7%,并改善图像质量与诊断准确率,尤其对膝下动脉。
研究设计与样本
- 前瞻性随机对照研究,纳入80例行下肢CTA患者并随机分为VHP组(n=40)与常规组(n=40),其中18例患者共72条动脉以DSA为参考标准评估血管狭窄程度的诊断准确率。
关键影像表现/征象
- VHP组图像质量各项评分均显著优于常规组(均p<0.05);VHP组胫前动脉与足背动脉的CT强化、信噪比及对比噪声比均优于常规组(均p<0.001)。
诊断标准与关键数值
- 以DSA为参考标准按血管节段分析,VHP组阳性预测值100% vs 常规组76.19%(p=0.01),准确率100% vs 84.38%(p=0.01)。
临床应用与阅片要点
- VHP扫描可在降低对比剂用量的同时改善下肢CTA图像质量与狭窄诊断准确率,尤其适用于膝下动脉评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to explore the feasibility of reducing contrast medium (CM) volume, improving image quality and diagnostic accuracy using variable helical pitch (VHP) scanning for patients with lower extremity arterial disease (LEAD).
MATERIALS AND METHODS: Eighty patients who underwent lower extremity CT angiography (CTA) were prospectively enrolled and randomly assigned to either the VHP group (n = 40) or the conventional group (n = 40). Quantitative parameters and qualitative scores were compared between the two groups. Additionally, out of these patients, 72 arteries from 18 patients had DSA as the reference standard, and the diagnostic accuracy for the degree of vessel stenosis was assessed and compared.
RESULTS: In the VHP group, the contrast volume was significantly lower than in the conventional group (79.55 ± 11.87 mL vs. 89.63 ± 10.03 mL, p < 0.001), showing a reduction of 12.7 %. For all image quality characteristics, scores in VHP group were significantly superior to those in the conventional groups (all p < 0.05). Quantitative analysis revealed that images from the VHP group exhibited superior CT enhancement, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the anterior tibial arteries (ATA) and dorsali pedis arteries (DPA) compared to the conventional group (all p < 0.001). Moreover, segment-based analysis showed the VHP group had significantly higher positive predictive value (PPV) and accuracy than the conventional group (PPV: 100 % vs. 76.19 %, p = 0.01; accuracy: 100 % vs. 84.38 %, p = 0.01, respectively).
CONCLUSIONS: The implementation of the VHP protocol led to a 12.7 % decrease in contrast medium dosage compared to the conventional lower extremity CTA scanning protocol. Furthermore, it improved image quality and diagnostic accuracy, particularly for arteries below the knee.