前瞻性研究纳入51例拟行腰椎CT检查的成人,利用光子计数探测器CT光谱定位像通过物质分解推导面积骨密度和T值,以双能X线吸收测定法为参考标准。PCD CT推导的T值与DEXA的T值一致性相关系数为0.90,检测骨量异常的敏感度97%、特异度71%、阳性预测值90%、阴性预测值91%。作者认为PCD CT光谱定位像推导的T值可能作为低骨量和骨质疏松的机会性筛查工具。

要点

  • PCD CT光谱定位像可机会性推导腰椎面积骨密度和T值,与DEXA的T值一致性相关系数达0.90。
  • 以DEXA为参考,PCD CT推导T值检测骨量异常(T值<-1.0)的敏感度97%、特异度71%、阳性预测值90%、阴性预测值91%。
  • PCD CT与DEXA推导的T值差异与年龄、检查间隔、BMI仅呈弱相关(r分别为-0.13、0.15、0.28),男女间无显著差异(p=.81)。

核心结论

  • 光子计数探测器CT光谱定位像在推导面积骨密度值及相应T值方面显示出临床实用性。

研究设计与样本

  • 前瞻性研究,纳入51例18岁及以上、于2023年10月至2024年2月期间拟行临床指征腰椎CT检查且既往13个月内或后续13个月内行DEXA的患者,采用光子计数探测器CT行腰椎CT并采集光谱定位像,以DEXA为参考标准。

诊断标准与关键数值

  • 将腰椎椎体和背景软组织放置ROI,利用物质分解从光谱定位像提取面积密度并推导腰椎面积骨密度值,进而推导T值;T值分为正常(≥-1.0)或异常(<-1.0)骨量。

临床应用与阅片要点

  • PCD CT光谱定位像推导的T值可能作为低骨量和骨质疏松的机会性筛查工具;所有CT检查均包含定位像,可对接受临床指征PCD CT检查的患者进行机会性骨质疏松筛查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Spectral localizer images from photon-counting detector (PCD) CT can be used for bone mineral density (BMD) evaluation given their 2D projectional nature and material decomposition capability. As all CT examinations include localizer images, this approach could allow opportunistic osteoporosis screening of patients undergoing clinically indicated imaging with PCD CT. OBJECTIVE. The purpose of this study was to assess the use of PCD CT spectral localizer images for opportunistic derivation of areal BMD (aBMD) values and T-scores, with dual-energy x-ray absorptiometry (DEXA) used as the reference standard. METHODS. This prospective study included patients 18 years old or older who were scheduled for a clinically indicated lumbar spine CT examination between October 2023 and February 2024 and who underwent DEXA within the previous 13 months or were scheduled for DEXA within the subsequent 13 months. Participants underwent lumbar spine CT by PCD CT including spectral localizer images. The lumbar spine aBMD was extracted from clinical DEXA reports. ROIs were placed on lumbar vertebral bodies and background soft tissues to extract areal densities from spectral localizer images using material decomposition; areal densities were used to derive lumbar spine aBMD values. The aBMD values were used to derive T-scores, which were classified as representing normal (≥ -1.0) or abnormal (< -1.0) bone mass. DEXA-derived and PCD CT-derived measurements were compared. RESULTS. The study included 51 participants (31 women and 20 men; mean age, 62 years [range, 28-83 years]). The mean DEXA-derived T-score was 0.4 ± 1.6 [SD], and the mean PCD CT-derived T-score was 0.3 ± 1.8 [SD] (p = .29). The Lin concordance correlation coefficient between DEXA-derived and PCD CT-derived T-scores was 0.90. The difference between DEXA-derived and PCD CT-derived T-scores showed a small correlation with patient age (r = -0.13), absolute interval between DEXA and PCD CT (r = 0.15), and BMI (r = 0.28); this difference in scores did not show a significant difference between men and women (0.08 vs 0.13, respectively; p = .81). PCD CT-derived T-scores had a sensitivity of 97%, specificity of 71%, PPV of 90%, and NPV of 91% for detecting abnormal bone mass, with DEXA-derived T-scores used as the reference standard. CONCLUSION. PCD CT spectral localizer images showed clinical utility in deriving aBMD values and, consequently, T-scores. CLINICAL IMPACT. The T-score derived from PCD CT spectral localizer images may serve as an opportunistic screening tool for low bone mass and osteoporosis.