基于肩关节MRI的多模态影像组学提高肩胛下肌损伤术前诊断准确性
多中心研究纳入324例来自某大型医学中心的患者作为训练与测试组,另60例来自两家其他医学中心作为验证组,提取每例每种序列1197个影像组学特征,评估各序列及多模态融合对肩胛下肌损伤的术前诊断效能;内部验证组多模态融合准确度0.828、AUC 0.916,外部验证组准确度0.867、AUC 0.803。
要点
- 多模态融合在内部验证组准确度0.828、AUC 0.916,优于各单序列。
- 外部验证组多模态融合准确度0.867、AUC 0.803。
- 每例每种序列提取1197个影像组学特征,用于术前诊断肩胛下肌损伤。
核心结论
- 将多模态影像组学技术应用于肩关节MRI可显著提高肩胛下肌损伤术前诊断的精确性。
- 该方法利用多种MRI模态提供的综合数据,提供更详细准确的评估,对手术规划和患者照护至关重要。
研究设计与样本
- 多中心研究,训练与测试组为来自某大型医学中心的324例患者,验证组为来自两家其他医学中心的60例患者。
- 所有受试者的影像方案包括肩关节MRI:T1加权冠状位序列,T2加权冠状位、轴位和矢状位图像。
- 采用影像组学分析,从MRI中提取大量定量特征,用于术前提高诊断准确性。
诊断标准与关键数值
- 内部验证组:冠状位T1加权准确度0.766、AUC 0.803;冠状位T2加权准确度0.781、AUC 0.844;轴位T2加权准确度0.719、AUC 0.761;矢状位T2加权准确度0.766、AUC 0.821;多模态融合准确度0.828、AUC 0.916。
- 外部验证组:冠状位T1加权准确度0.833、AUC 0.819;冠状位T2加权准确度0.767、AUC 0.794;轴位T2加权准确度0.783、AUC 0.797;矢状位T2加权准确度0.833、AUC 0.800;多模态融合准确度0.867、AUC 0.803。
- 每例每种成像模态提取1197个影像组学特征。
临床应用与阅片要点
- 原文结论认为多模态影像组学用于肩关节MRI可提高肩胛下肌损伤术前诊断精确性,对手术规划有潜在价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Rotator cuff injury is a common ailment in the musculoskeletal system, with the subscapularis muscle being the largest and most robust muscle of the rotator cuff. The occurrence of subscapularis muscle tears is more frequent than previously reported. The main objective of this research is to harness the power of artificial intelligence to enhance the precision in diagnosing subscapularis muscle injuries via magnetic resonance imaging of the shoulder joint, prior to surgical intervention. This study seeks to integrate advanced artificial intelligence algorithms to analyze magnetic resonance imaging data, aiming to provide more accurate preoperative assessments, which can potentially lead to better surgical outcomes and patient care and promote technological progress in the field of medical imaging analysis.
METHOD: This is a multicenter study that involves 324 patients from a major medical center serving as both the training and testing groups, with an additional 60 patients from two other medical centers comprising the verifying group. The imaging protocol for all these subjects included a series of shoulder magnetic resonance imaging scans: T1-weighted coronal sequences, T2-weighted coronal, axial, and sagittal images. These comprehensive imaging modalities were utilized to thoroughly examine the shoulder joint's anatomical details and to detect any signs of subscapularis muscle damage. To enhance the diagnostic accuracy before surgical procedures, radiomic analysis was employed. This technique involves the extraction of a multitude of quantitative features from the magnetic resonance imaging, which can provide a more nuanced and data-driven approach to identifying subscapularis muscle injuries. The integration of radiomics in this study aims to offer a more precise preoperative assessment, potentially leading to improved surgical planning and patient outcomes.
RESULT: In the course of this study, a comprehensive extraction of 1197 radiomic features was performed for each imaging modality of every patient. The coronal T1-weighted modality, when assessed within the internal verifying cohort, delivered a diagnostic accuracy of 0.766, coupled with an AUC of 0.803. In the case of the T2-weighted modality, the coronal planes exhibited a diagnostic accuracy of 0.781 and an AUC of 0.844. The axial T2-weighted images recorded an accuracy of 0.719 and an AUC of 0.761, while the sagittal T2-weighted images scored an accuracy of 0.766 and an AUC of 0.821. The amalgamation of these imaging techniques through a multimodal strategy markedly enhanced the accuracy to 0.828, with an AUC of 0.916 for the internal verifying group. The diagnostic performance of the coronal T1-weighted modality in the external verifying cohort yielded an accuracy of 0.833, with an area under the curve (AUC) of 0.819. For the T2-weighted modality, the coronal imaging demonstrated an accuracy of 0.767 and an AUC of 0.794. The axial T2-weighted images had an accuracy of 0.783 and an AUC of 0.797, while the sagittal T2-weighted images achieved an accuracy of 0.833 and an AUC of 0.800. When combining the modalities, the multimodal approach significantly improved the accuracy to 0.867, with an AUC of 0.803 in the external verifying group, indicating a robust diagnostic capability.
CONCLUSION: Our study demonstrates that the application of multimodal radiomic techniques to shoulder magnetic resonance imaging significantly enhances the precision of preoperative diagnosis for subscapularis muscle injuries. This approach leverages the comprehensive data provided by various magnetic resonance imaging modalities to offer a more detailed and accurate assessment, which is crucial for surgical planning and patient care.
引用
- He Z, Fang K, Lin X, et al. Enhancing Preoperative Diagnosis of Subscapular Muscle Injuries with Shoulder MRI-based Multimodal Radiomics. Acad Radiol. 2024. PMID: 39370313. doi:10.1016/j.acra.2024.09.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。