文献速递骨肌技术与安全MR

新一代低场MRI改善金属伪影抑制:一项生物体模可行性研究

Improved metal suppression using new generation low-field MRI: a biophantom feasibility study.
PubMed 文献 · Skeletal Radiol · 2024-10-04

在12个猪膝关节标本中植入钢和钛螺钉,比较0.55 T与3.0 T MRI在TSE、TSE联合视角倾斜(VAT)及SEMAC序列(PD和T2w-STIR对比)下的金属伪影大小和解剖结构显示。0.55 T金属伪影显著更小,SEMAC序列下伪影相对缩小(不锈钢78.7%和79.4%,钛45.3%和1.4%),解剖结构显示更优;作者指出需进一步临床研究以阐明患者相关获益。

要点

  • 0.55 T MRI金属伪影显著小于3.0 T,SEMAC序列伪影最小。
  • 0.55 T解剖结构(软骨、骨、生长板、交叉韧带)显示优于3.0 T。
  • 钛螺钉伪影缩小幅度因序列而异(45.3%和1.4%),不锈钢缩小更明显。

核心结论

  • 在新型0.55 T MRI系统上可实现金属伪影的显著缩小,从而获得更优的解剖结构显示。

研究设计与样本

  • 生物体模可行性研究,在12个猪膝关节标本中植入钢和钛螺钉,于0.55 T和3.0 T MRI上采用TSE、TSE联合VAT及SEMAC序列(PD和T2w-STIR对比)成像,测量伪影并评估解剖结构显示。

关键影像表现/征象

  • 0.55 T金属伪影显著更小。
  • SEMAC序列在0.55 T下PD和T2w-STIR序列伪影最小:不锈钢相对3.0 T分别缩小78.7%和79.4%,钛分别缩小45.3%和1.4%。
  • 0.55 T解剖结构(软骨、骨、生长板、交叉韧带)显示优于3.0 T。

局限性

  • 作者指出需进一步临床研究以阐明患者相关获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Novel 0.55 MRI scanners have the potential to reduce metal artifacts around orthopedic implants. The purpose of this study was to compare metal artifact size and depiction of anatomy between 0.55 T and 3.0 T MRI in a biophantom.

MATERIALS AND METHODS: Steel and titanium screws were implanted in 12 porcine knee specimens and imaging at 0.55 T and 3 T MRI was performed using the following sequences: turbo spin-echo (TSE), TSE with view angle tilting (VAT), and slice encoding for metal artifact correction (SEMAC) with proton-density (PD) and T2-weighted short-tau inversion-recovery (T2w-STIR) contrasts. Artifacts were measured, and visualization of anatomy (cartilage, bone, growth plates, cruciate ligaments) was assessed and compared between groups.

RESULTS: Metal artifacts were significantly smaller at 0.55 T. The smallest artifact sizes were achieved with SEMAC at 0.55 T for both PD and T2w-STIR sequences; corresponding relative size reductions vs. 3.0 T were 78.7% and 79.4% (stainless steel) and 45.3% and 1.4% (titanium). Depiction of anatomical structures was superior at 0.55 T.

CONCLUSION: Substantial reduction of artifact size resulting in superior depiction of anatomical structures is possible on novel 0.55 T MRI systems. Further clinical studies are required to elucidate patient-relevant advantages.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Luitjens J, Ziegeler K, Yoon D, et al. Improved metal suppression using new generation low-field MRI: a biophantom feasibility study. Skeletal Radiol. 2024. PMID: 39365346. doi:10.1007/s00256-024-04809-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。