基于MRI的零回波时间与黑骨伪CT对比全身CT检测多发性骨髓瘤溶骨性病变
这项前瞻性研究纳入47例多发性骨髓瘤患者,评估基于MRI的零回波时间(ZTE)和梯度回波黑骨(BB)伪CT序列检测溶骨性病变的诊断准确性、重复性和再现性,以全身CT为参考标准。经验丰富的阅片者中,BB和ZTE在每患者分析中准确率均为98%,BB每区域准确率83%-100%,ZTE为74%-94%;ZTE在脊柱的假阴性增加17%至23%。结论认为两种伪CT序列均具有高诊断准确性,但ZTE在脊柱的假阴性多于BB。
要点
- 经验丰富阅片者中,BB和ZTE每患者诊断准确率均为98%。
- ZTE在脊柱的假阴性较BB增加+17%至+23%,按腰椎节段不同(P < .013)。
- 两种序列重复性均很好(AC1≥0.87),再现性至少良好(AC2≥0.63)。
核心结论
- 基于MRI的ZTE和BB伪CT序列在检测多发性骨髓瘤溶骨性病变方面均表现出高诊断准确性,但ZTE在脊柱的假阴性 findings 多于BB。
研究设计与样本
- 前瞻性研究,纳入47例参与者(平均年龄67岁±11岁,27例男性),连续入组于学术医院,时间为2021年6月至2022年12月;参与者接受3-T全身MRI的ZTE和BB序列(覆盖腰椎、骨盆和股骨近端)以及1个月内临床指征的18F-FDG PET/CT(包括优化的全身CT);由三名放射科医生(两名经验丰富,一名不熟悉伪CT阅片)评估10个骨区域和两种评分(分类评分=溶骨性病变存在/不存在;半定量评分=溶骨性病变计数)。
关键影像表现/征象
- ZTE序列在脊柱的假阴性较BB增加+17%至+23%,按腰椎节段不同(P < .013)。
- 除髋骨外,无论区域,BB评分减ZTE评分的差异呈正偏态(P < .021)。
诊断标准与关键数值
- 经验丰富阅片者中,BB和ZTE在每患者分析中准确率均为98%。
- 经验丰富阅片者中,BB每区域准确率范围为83%-100%,ZTE为74%-94%。
- 分类评分的重复性:无论序列或区域,AC1≥0.87(很好)。
- 分类评分的再现性:无论序列或区域,AC2≥0.63(至少良好)。
临床应用与阅片要点
- 基于MRI的ZTE和BB伪CT序列可用于检测多发性骨髓瘤的溶骨性病变。
- 与BB相比,ZTE序列在脊柱产生更多假阴性 findings。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background MRI is highly sensitive for assessing bone marrow involvement in multiple myeloma (MM) but does not enable detection of osteolysis. Purpose To assess the diagnostic accuracy, repeatability, and reproducibility of pseudo-CT MRI sequences (zero echo time [ZTE], gradient-echo black bone [BB]) in detecting osteolytic lesions in MM using whole-body CT as the reference standard. Materials and Methods In this prospective study, consecutive patients were enrolled in our academic hospital between June 2021 and December 2022. Inclusion criteria were newly diagnosed MM, monoclonal gammopathy of undetermined significance at high risk for MM, or suspicion of progressive MM. Participants underwent ZTE and BB sequences covering the lumbar spine, pelvis, and proximal femurs as part of 3-T whole-body MRI examinations, as well as clinically indicated fluorine 18 fluorodeoxyglucose PET/CT examination within 1 month that included optimized whole-body CT. Ten bone regions and two scores (categorical score = presence/absence of osteolytic lesion; semiquantitative score = osteolytic lesion count) were assessed by three radiologists (two experienced and one unfamiliar with pseudo-CT reading) on the ZTE, BB, and whole-body CT images. The accuracy, repeatability, and reproducibility of categorical scores (according to Gwet agreement coefficients AC1 and AC2) and differences in semiquantitative scores were assessed at the per-sequence, per-region, and per-patient levels. Results A total of 47 participants (mean age, 67 years ± 11 [SD]; 27 male) were included. In experienced readers, BB and ZTE had the same high accuracy (98%) in the per-patient analysis, while BB accuracy ranged 83%-100% and ZTE accuracy ranged 74%-94% in the per-region analysis. An increase of false-negative (FN) findings in the spine ranging from +17% up to +23%, according to the lumbar vertebra, was observed using ZTE (P < .013). Regardless of the region (except coxal bones), differences in the BB score minus the ZTE score were positively skewed (P < .021). Regardless of the sequence or region, repeatability was very good (AC1 ≥0.87 for all), while reproducibility was at least good (AC2 ≥0.63 for all). Conclusion Both MRI-based ZTE and BB pseudo-CT sequences of the lumbar spine, pelvis, and femurs demonstrated high diagnostic accuracy in detecting osteolytic lesions in MM. Compared with BB, the ZTE sequence yielded more FN findings in the spine. ClinicalTrials.gov Identifier: NCT05381077 Published under a CC BY 4.0 license. Supplemental material is available for this article.
引用
- Lecouvet FE, Zan D, Lepot D, et al. MRI-based Zero Echo Time and Black Bone Pseudo-CT Compared with Whole-Body CT to Detect Osteolytic Lesions in Multiple Myeloma. Radiology. 2024. PMID: 39377681. doi:10.1148/radiol.231817
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。