PubMed 文献 · J Ultrasound Med · 2024-10-15

本研究纳入2011至2021年间125例永久性先天性甲状腺功能减退症婴儿,比较左膝超声与X线摄影对股骨与胫骨骨骺骨化中心(存在/缺失)的检出一致性。超声与X线摄影对股骨中心检出的一致率为99%,对胫骨中心为100%,观察者间一致性为中等至几乎完全一致。结论认为超声在检测膝关节骨化中心方面与X线摄影同样有效,可与甲状腺检查同时进行以替代X线摄影。

要点

  • 超声检出股骨骨化中心108例(86.4%),X线摄影检出106例(84.8%),两者一致率99%。
  • 胫骨骨化中心在超声与X线摄影均检出84例(67.2%),两者一致率100%。
  • 超声与X线摄影检测膝关节骨化中心的观察者间一致性为中等至几乎完全一致。

核心结论

  • 在永久性先天性甲状腺功能减退症婴儿中,超声检测膝关节股骨与胫骨骨骺骨化中心与X线摄影同样有效,可在甲状腺检查同时进行以替代X线摄影。

研究设计与样本

  • 研究纳入2011至2021年所有因永久性先天性甲状腺功能减退症转诊行甲状腺超声的婴儿,同日行左膝超声与X线摄影;由两名儿科放射科医师对膝关节X线片与声像图进行共识判读,识别股骨与胫骨骨骺骨化中心的存在/缺失,并评估超声与X线摄影的一致性;另由一名放射科医师进行第二次延迟判读以评估观察者间一致性;共125例患者(65例女,60例男),平均年龄24天(5天至5个月)。

关键影像表现/征象

  • 超声检出股骨骨化中心108例(86.4%),X线摄影检出106例(84.8%)。
  • 胫骨骨化中心在超声与X线摄影均检出84例(67.2%)。
  • 股骨与胫骨骨化中心在超声与X线摄影均存在者84例(67.2%)。
  • 单一骨化核在超声见于24例(19.2%),在X线摄影见于22例(17.6%),所有病例均对应股骨中心。

诊断标准与关键数值

  • 超声与X线摄影检测股骨骨化中心的一致率为99%,检测胫骨骨化中心的一致率为100%。
  • 超声与X线摄影检测骨化中心的观察者间一致性为中等至几乎完全一致。

临床应用与阅片要点

  • 在永久性先天性甲状腺功能减退症婴儿中,膝关节超声可与甲状腺超声同时进行,以替代X线摄影检测股骨与胫骨骨骺骨化中心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To demonstrate the usefulness of ultrasonography in detecting knee ossification centers in infants with permanent congenital hypothyroidism (PCH).

METHODS: From 2011 to 2021, all infants with PCH referred for thyroid ultrasound also underwent left knee ultrasound and radiography on the same day. Knee radiographs were compared with knee sonograms. Two pediatric radiologists reviewed the consensus knee radiographs and sonograms to identify femoral and tibial epiphyseal ossification centers (presence/absence). The concordance between ultrasonography and radiography was assessed. Another radiologist conducted a second late review to evaluate interobserver agreement.

RESULTS: We identified 125 patients (65 girls, 60 boys) with a mean age of 24 days (5 days-5 months). On scintigraphy, the thyroid was in place in 66.4%, ectopic in 24%, and absent in 9.6% of patients. The femoral center was observed in 108 patients (86.4%) via sonography and 106 patients (84.8%) via radiography. The tibial center was observed in 84 patients (67.2%) via sonography and radiography. Both femoral and tibial centers were present on sonography and radiography in 84 patients (67.2%). A single nucleus was present in 24 patients (19.2%) on sonography and 22 patients (17.6%) on radiography; it corresponded to the femoral center in all patients. The concordance between ultrasonography and radiography was 99% and 100%, respectively, for the detection of the femoral and tibial centers. Interobserver agreement was substantial to almost perfect for both ultrasonography and radiography.

CONCLUSION: Ultrasonography is as effective as radiography in detecting knee ossification centers in PCH. It can be performed at the same time as thyroid examination, in place of radiography.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Chiri C, Rapilat D, Avni F, et al. Comparison Between Ultrasonography and Radiography in the Detection of Epiphyseal Ossification Centers of the Knee in Infants With Permanent Congenital Hypothyroidism. J Ultrasound Med. 2024. PMID: 39404054. doi:10.1002/jum.16603