文献速递乳腺乳腺X线

使用俯卧式活检台的对比增强乳腺摄影(CEM)引导活检:单中心CEM转诊中心初步经验的回顾性分析

Contrast enhanced mammography (CEM) guided biopsy using a prone table: A retrospective analysis of the preliminary experience in a single CEM referral center.
PubMed 文献 · Eur J Radiol · 2024-10-09

该单中心回顾性分析评估了Giotto Class 30,000系统俯卧位CEM引导活检的操作效能与患者体验,共对37个仅强化病灶(EOL)进行活检,技术成功率100%,平均操作时间15.8分钟,并发症发生率27%(主要为血肿),组织学阳性发现率97.3%。作者认为该初步结果验证了这一创新方法,但需进一步研究以巩固这些发现并探索长期结局。

要点

  • CEM引导俯卧位活检对仅强化病灶(EOL)技术成功率达100%,平均操作时间15.8分钟。
  • 并发症发生率为27%,主要为血肿,另有因患者要求或晕厥导致的操作中断。
  • 组织学显著发现率为97.3%,提示对EOL活检具有较高的病理检出价值。

核心结论

  • 使用Giotto Class 30,000系统进行俯卧位CEM引导活检显示出高操作成功率和良好的患者耐受性,作者认为该初步结果验证了这一创新方法,但需进一步研究以巩固发现并探索长期结局。

研究设计与样本

  • 单中心回顾性分析,纳入2023年12月至2024年6月共524次CEM检查中至少有一个EOL的患者,采用双能成像和真空辅助活检技术,排除未在本机构进行初次或随访CEM者。

诊断标准与关键数值

  • 技术成功定义为活检完成且取样充分,本研究中37个EOL活检的技术成功率为100%,组织学显著发现率为97.3%。

临床应用与阅片要点

  • 作者认为俯卧位CEM引导活检可能提升操作舒适度和效率,但需进一步研究以巩固这些初步发现并探索长期结局。

局限性

  • 原文结论指出这些为初步结果,需进一步研究以巩固发现并探索长期结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: This study evaluates the procedural efficacy and patient experience of Contrast Enhanced Mammography (CEM)-guided biopsies performed in a prone position using the Giotto Class 30,000 system. The emphasis is on the procedural advantages and clinical outcomes for "enhancing-only lesions" (EOLs).

METHODS: A retrospective analysis of 524 CEM examinations conducted from December 2023 to June 2024 at a tertiary referral center was performed. Patients referred for pre-surgical staging or evaluation of inconclusive findings from conventional imaging were included. The study utilized dual-energy imaging and vacuum-assisted biopsy techniques, focusing on patients with at least one EOL identified in their initial CEM. Exclusions were based on the absence of a primary or follow-up CEM conducted at our facility Endpoints of this work included procedure efficiency which was evaluated in terms of technical success (biopsy completion with adequate sampling), dose distribution and timing and detection of additional lesions and patients' comfort evaluation, based on the rate of complications (hematomas) and procedure interruption due to patients' specific request or fainting events.

RESULTS: Among the evaluated cases, 37 EOLs were biopsied. The average procedure time was 15.8 min. Biopsies were successfully completed in 100% of cases. However, complications occurred in 27% of cases, primarily as hematomas and a significant histological finding rate of 97.3% was recorded.

CONCLUSIONS: The use of the Giotto Class 30,000 system for CEM-guided biopsies in a prone position demonstrated high procedural success and was well-tolerated by patients, highlighting its potential to enhance procedural comfort and efficiency. These preliminary results validate the innovative approach, though further studies are required to solidify these findings and explore long-term outcomes.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nori Cucchiari J, Giudice L, Incardona LA, et al. Contrast enhanced mammography (CEM) guided biopsy using a prone table: A retrospective analysis of the preliminary experience in a single CEM referral center. Eur J Radiol. 2024. PMID: 39388793. doi:10.1016/j.ejrad.2024.111779

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。