筛查性对比增强乳腺摄影在乳腺极度致密且乳腺癌风险增高的女性中的诊断准确性
本回顾性单机构研究纳入2012年12月至2022年3月间1299次筛查性对比增强乳腺摄影(CEM)检查(609例无症状女性,平均年龄50岁±9),评估CEM在乳腺极度致密(BI-RADS D类)女性中的诊断性能。CEM敏感度88.9%(16/18;95%CI:65.3,98.6)高于低能量图像27.8%(5/18;95%CI:9.7,53.5)(P=.003),但特异度88.9%(1108/1246;95%CI:87.0,90.6)低于低能量图像96.2%(1199/1246;95%CI:95.0,97.2)(P<.001),随访时CEM特异度改善至90.7%(705/777;95%CI:88.5,92.7;P=.01)。
要点
- 在乳腺极度致密女性筛查中,CEM敏感度88.9%,高于低能量图像的27.8%(P=.003)。
- CEM特异度88.9%,低于低能量图像的96.2%(P<.001),但随访时改善至90.7%(P=.01)。
- CEM额外检出11例癌症,增量癌症检出率为每1000次检查8.7例。
核心结论
- 与低能量成像相比,CEM在乳腺极度致密女性中显示更高敏感度但更低特异度,尽管随访时特异度有所改善。
研究设计与样本
- 回顾性单机构研究,纳入2012年12月至2022年3月连续筛查性CEM检查1299次(609例无症状女性,平均年龄50岁±9),低能量图像相当于二维全视野数字乳腺摄影,重组图像通过后处理算法构建。
关键影像表现/征象
- 低能量图像上可见5例癌症,CEM额外显示11例癌症,增量癌症检出率为每1000次检查8.7例癌症。
- 共诊断16例筛查检出癌症,发生2例间期癌症。
诊断标准与关键数值
- CEM(含低能量和重组图像)敏感度88.9%(16/18;95%CI:65.3,98.6),低能量图像敏感度27.8%(5/18;95%CI:9.7,53.5),P=.003。
- CEM特异度88.9%(1108/1246;95%CI:87.0,90.6),低能量图像特异度96.2%(1199/1246;95%CI:95.0,97.2),P<.001。
- 随访时CEM特异度90.7%(705/777;95%CI:88.5,92.7),与基线相比P=.01。
临床应用与阅片要点
- 在乳腺极度致密(BI-RADS D类)且乳腺癌风险增高的无症状女性筛查中,CEM较低能量图像检出更多癌症,但需注意特异度较低。
- 随访时CEM特异度改善至90.7%,提示阅片经验或随访阶段可能影响特异度表现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Mammogram interpretation is challenging in female patients with extremely dense breasts (Breast Imaging Reporting and Data System [BI-RADS] category D), who have a higher breast cancer risk. Contrast-enhanced mammography (CEM) has recently emerged as a potential alternative; however, data regarding CEM utility in this subpopulation are limited. Purpose To evaluate the diagnostic performance of CEM for breast cancer screening in female patients with extremely dense breasts. Materials and Methods This retrospective single-institution study included consecutive CEM examinations in asymptomatic female patients with extremely dense breasts performed from December 2012 to March 2022. From CEM examinations, low-energy (LE) images were the equivalent of a two-dimensional full-field digital mammogram. Recombined images highlighting areas of contrast enhancement were constructed using a postprocessing algorithm. The sensitivity and specificity of LE images and CEM images (ie, including both LE and recombined images) were calculated and compared using the McNemar test. Results This study included 1299 screening CEM examinations (609 female patients; mean age, 50 years ± 9 [SD]). Sixteen screen-detected cancers were diagnosed, and two interval cancers occured. Five cancers were depicted at LE imaging and an additional 11 cancers were depicted at CEM (incremental cancer detection rate, 8.7 cancers per 1000 examinations). CEM sensitivity was 88.9% (16 of 18; 95% CI: 65.3, 98.6), which was higher than the LE examination sensitivity of 27.8% (five of 18; 95% CI: 9.7, 53.5) (P = .003). However, there was decreased CEM specificity (88.9%; 1108 of 1246; 95% CI: 87.0, 90.6) compared with LE imaging (specificity, 96.2%; 1199 of 1246; 95% CI: 95.0, 97.2) (P < .001). Compared with specificity at baseline, CEM specificity at follow-up improved to 90.7% (705 of 777; 95% CI: 88.5, 92.7; P = .01). Conclusion Compared with LE imaging, CEM showed higher sensitivity but lower specificity in female patients with extremely dense breasts, although specificity improved at follow-up. © RSNA, 2024 See also the editorial by Lobbes in this issue.
引用
- Nissan N, Comstock CE, Sevilimedu V, et al. Diagnostic Accuracy of Screening Contrast-enhanced Mammography for Women with Extremely Dense Breasts at Increased Risk of Breast Cancer. Radiology. 2024. PMID: 39352285. doi:10.1148/radiol.232580
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。