超声应变弹性成像通过重新分类BI-RADS 3和4a类病灶提高乳腺病灶诊断性能:一项多中心诊断研究
该多中心诊断研究纳入32家医院4371例接受超声和应变弹性成像(SE)的BI-RADS 2-5类实性乳腺病灶患者,评估弹性评分(ES)和应变比(SR)联合BI-RADS及两种重新分类方法的诊断性能。结果显示联合SE的AUC高于单独BI-RADS(0.822-0.898 vs 0.794,P<.01),仅下调BI-RADS 4a类病灶的AUC、特异度和准确度更高(P<.01)且敏感度相似(P>.05),联合SE可减少17.64%-55.20%的不必要活检。
要点
- 联合应变弹性成像(SE)的AUC为0.822-0.898,高于单独BI-RADS的0.794(P<.01)。
- 仅下调BI-RADS 4a类病灶的AUC、特异度和准确度高于上调3类并下调4a类(P<.01),敏感度相似(P>.05)。
- 联合SE与BI-RADS可减少17.64%-55.20%的不必要活检。
核心结论
- 联合BI-RADS与SE提高了鉴别乳腺病灶良恶性的诊断性能,并可降低假阳性乳腺活检率;仅下调BI-RADS 4a类病灶可能足以获得良好诊断性能。
研究设计与样本
- 多中心诊断研究,纳入32家医院4371例接受超声和SE的BI-RADS 2-5类实性乳腺病灶患者,依据弹性评分(ES)和应变比(SR)评估弹性图像,采用三种联合方法(BI-RADS+ES、BI-RADS+SR、BI-RADS+ES+SR)和两种重新分类方法(方法一:上调BI-RADS 3类并下调BI-RADS 4a类;方法二:仅下调BI-RADS 4a类),评估诊断性能及潜在减少不必要活检。
诊断标准与关键数值
- 联合BI-RADS与SE的AUC为0.822-0.898,高于单独BI-RADS的0.794(P<.01)。
- 重新分类方法一:BI-RADS+ES的敏感度99.36%、特异度66.70%、准确度78.36%;BI-RADS+SR的敏感度98.01%、特异度66.45%、准确度77.72%;BI-RADS+ES+SR的敏感度99.42%、特异度66.70%、准确度78.38%。
- 重新分类方法二:BI-RADS+ES的敏感度99.17%、特异度70.72%、准确度80.87%;BI-RADS+SR的敏感度97.76%、特异度81.75%、准确度87.46%;BI-RADS+ES+SR的敏感度99.23%、特异度69.83%、准确度80.32%。
- 仅下调BI-RADS 4a类病灶的AUC、特异度和准确度高于上调BI-RADS 3类并下调BI-RADS 4a类(P<.01),敏感度相似(P>.05)。
临床应用与阅片要点
- 联合BI-RADS与SE可提高鉴别乳腺病灶良恶性的诊断性能,并可能减少不必要活检。
- 仅下调BI-RADS 4a类病灶可能足以获得良好诊断性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the added value of strain elastography (SE) by recategorizing ultrasound (US) breast imaging reporting and data system (BI-RADS) 3 and 4a lesions.
METHODS: A total of 4371 patients underwent US and SE with BI-RADS 2-5 categories solid breast lesions were included from 32 hospitals. We evaluated the elastographic images according to elasticity scores (ES) and strain ratios (SR). Three combined methods (BI-RADS + ES, BI-RADS + SR, BI-RADS + ES + SR) and two reclassified methods were used (method one: upgrading BI-RADS 3 and downgrading BI-RADS 4a, method two: downgrading BI-RADS 4a alone). The diagnostic performance and the potential reduction of unnecessary biopsies were evaluated.
RESULTS: Combining BI-RADS with SE had a higher area under the curve (AUC) than BI-RADS alone (0.822-0.898 vs 0.794, P < .01). For reclassified method one, the sensitivity, specificity, and accuracy were 99.36%, 66.70%, 78.36% for BI-RADS + ES and 98.01%, 66.45%, 77.72% for BI-RADS + SR, and 99.42%, 66.70%, 78.38% for BI-RADS + ES + SR, respectively. For reclassified method two, the sensitivity, specificity, and accuracy were 99.17%, 70.72%, 80.87% for BI-RADS + ES and 97.76%, 81.75%, 87.46% for BI-RADS + SR, and 99.23%, 69.83%, 80.32% for BI-RADS + ES + SR, respectively. Downgrading BI-RADS 4a alone had higher AUC, specificity, and accuracy (P < .01) and similar sensitivity (P > .05) to upgrading BI-RADS 3 and downgrading BI-RADS 4a. Combining SE with BI-RADS could help reduce unnecessary biopsies by 17.64%-55.20%.
CONCLUSIONS: Combining BI-RADS with SE improved the diagnostic performance in distinguishing benign from malignant lesions and could decrease false-positive breast biopsy rates. Downgrading BI-RADS 4a lesions alone might be sufficient for achieving good diagnostic performance.
ADVANCES IN KNOWLEDGE: Downgrading BI-RADS category 4a lesions alone had higher AUC, specificity, and accuracy, and similar sensitivity to upgrading or downgrading BI-RADS category 3 and 4a lesions.