文献速递乳腺乳腺X线

按促进视觉适应的特征排序乳腺筛查钼靶以提高放射科医师阅片表现

Enhancing Radiologist Reading Performance by Ordering Screening Mammograms Based on Characteristics That Promote Visual Adaptation.
PubMed 文献 · Radiology · 2024-01-01

这项回顾性多阅片者多病例研究纳入150例女性(75例乳腺癌、75例无乳腺癌)的筛查钼靶,由13名放射科医师分别按随机、按体积乳腺密度(VBD)递增、按自监督学习(SSL)编码分组三种顺序阅片。按VBD递增排序较随机排序AUC升高(0.93 vs 0.92,P=.009),阅片时间、注视次数及恶性区域注视时间减少;SSL排序与随机排序AUC无差异,阅片时间反而延长。

要点

  • 按VBD从低到高排序阅片较随机排序AUC由0.92升至0.93(P=.009),敏感度与特异度无显著差异。
  • VBD排序较随机排序阅片时间缩短(24.3 vs 27.9秒,P<.001),注视次数减少(47 vs 52,P<.001)。
  • SSL编码分组排序与随机排序AUC无差异(0.92,P=.70),阅片时间延长(28.4 vs 27.9秒,P=.02)。

核心结论

  • 按VBD从低到高排序筛查钼靶可提高阅片AUC并减少阅片时间与注视指标,SSL编码分组排序未见AUC改善且阅片时间延长。

研究设计与样本

  • 回顾性多阅片者多病例研究,纳入2016年9月至2019年5月间的筛查钼靶,150名女性共150例检查(每例4幅图像,75例乳腺癌、75例无乳腺癌),由13名放射科医师按随机、VBD递增、SSL编码三种顺序阅片,并使用眼动仪记录眼动。

诊断标准与关键数值

  • 按VBD递增排序较随机排序AUC 0.93(95%CI 0.91,0.96)vs 0.92(95%CI 0.89,0.95),P=.009。
  • VBD排序与随机排序敏感度均为81%(794/975 vs 788/975),P=.78;特异度89%(871/975)vs 86%(837/975),P=.04。
  • SSL排序较随机排序AUC 0.92(95%CI 0.89,0.95),P=.70;敏感度80%(784/975),P=.79;特异度84%(820/975),P=.37。

临床应用与阅片要点

  • 按VBD从低到高排序阅片较随机排序阅片时间24.3 vs 27.9秒(P<.001),注视次数47 vs 52(P<.001),恶性区域注视时间3.7 vs 4.6秒(P<.001)。
  • SSL排序较随机排序注视次数54 vs 52(P=.05),恶性区域注视时间4.6 vs 4.6秒(P>.99),阅片时间28.4 vs 27.9秒(P=.02)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Mammographic background characteristics may stimulate human visual adaptation, allowing radiologists to detect abnormalities more effectively. However, it is unclear whether density, or another image characteristic, drives visual adaptation. Purpose To investigate whether screening performance improves when screening mammography examinations are ordered for batch reading according to mammographic characteristics that may promote visual adaptation. Materials and Methods This retrospective multireader multicase study was performed with mammograms obtained between September 2016 and May 2019. The screening examinations, each consisting of four mammograms, were interpreted by 13 radiologists in three distinct orders: randomly, by increasing volumetric breast density (VBD), and based on a self-supervised learning (SSL) encoding (examinations automatically grouped as "looking similar"). An eye tracker recorded radiologists' eye movements during interpretation. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of random-ordered readings were compared with those of VBD- and SSL-ordered readings using mixed-model analysis of variance. Reading time, fixation metrics, and perceived density were compared using Wilcoxon signed-rank tests. Results Mammography examinations (75 with breast cancer, 75 without breast cancer) from 150 women (median age, 55 years [IQR, 50-63]) were read. The examinations ordered by increasing VBD versus randomly had an increased AUC (0.93 [95% CI: 0.91, 0.96] vs 0.92 [95% CI: 0.89, 0.95]; P = .009), without evidence of a difference in specificity (89% [871 of 975] vs 86% [837 of 975], P = .04) and sensitivity (both 81% [794 of 975 vs 788 of 975], P = .78), and a reduced reading time (24.3 vs 27.9 seconds, P < .001), fixation count (47 vs 52, P < .001), and fixation time in malignant regions (3.7 vs 4.6 seconds, P < .001). For SSL-ordered readings, there was no evidence of differences in AUC (0.92 [95% CI: 0.89, 0.95]; P = .70), specificity (84% [820 of 975], P = .37), sensitivity (80% [784 of 975], P = .79), fixation count (54, P = .05), or fixation time in malignant regions (4.6 seconds, P > .99) compared with random-ordered readings. Reading times were significantly higher for SSL-ordered readings compared with random-ordered readings (28.4 seconds, P = .02). Conclusion Screening mammography examinations ordered from low to high VBD improved screening performance while reducing reading and fixation times. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grimm in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Gommers JJJ, Verboom SD, Duvivier KM, et al. Enhancing Radiologist Reading Performance by Ordering Screening Mammograms Based on Characteristics That Promote Visual Adaptation. Radiology. 2024. PMID: 39377678. doi:10.1148/radiol.240237

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。