经会阴超声自动评估产程中胎头位置的自动化方法
这项前瞻性观察研究纳入27例第二产程头位孕妇,采集45次二维经会阴超声图像,比较自动算法、数字阴道检查与专家超声评估胎头位置。自动算法与专家评估强相关(ρ=0.97),RMSE为0.32 cm,优于数字阴道检查(ρ=0.66,RMSE=0.97 cm)。
要点
- 自动算法与专家超声评估胎头位置强相关(ρ=0.97),RMSE为0.32 cm。
- 数字阴道检查与专家超声评估相关性较低(ρ=0.66),RMSE为0.97 cm。
- Bland-Altman分析显示算法偏倚更小、一致性界限更窄。
核心结论
- 所提出的算法能以高准确度和低RMSE评估胎头位置,可能促进超声在产程中的应用并支持临床人员管理产程。
研究设计与样本
- 前瞻性观察研究,纳入27例第二产程头位孕妇,共采集45次二维B模式经会阴超声图像。
- 以专家超声医师在同一经会阴超声采集上的胎头位置评估(FHSexp)作为金标准。
- 自动算法评估(FHSaut)与数字阴道检查(FHSdig)分别与金标准比较。
诊断标准与关键数值
- FHSaut与FHSexp强相关(ρ=0.97,p<0.001),决定系数R2=0.95。
- FHSdig与FHSexp相关性较低(ρ=0.66,p<0.001),决定系数R2=0.52。
- FHSaut的RMSE=0.32 cm,低于FHSdig的RMSE=0.97 cm。
- Bland-Altman分析显示算法较数字阴道检查偏倚更小、一致性界限更窄。
临床应用与阅片要点
- 自动算法可在经会阴超声图像上评估胎头位置,与专家超声评估高度一致。
- 作者认为该方法可能促进超声在产程中的应用,支持临床人员管理产程。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Accurate assessment of fetal head station (FHS) is crucial during labor management to reduce the risk of complications and plan the mode of delivery. Although digital vaginal examination (DVE) has been associated with inaccuracies in FHS assessment, ultrasound (US) evaluation remains dependent on sonographer expertise. This study aimed at investigating the reliability and accuracy of an automatic approach to assess the FHS during labor with transperineal US (TPU).
MATERIALS AND METHODS: In this prospective observational study, 27 pregnant women in the second stage of labor, with fetuses in cephalic presentation, underwent conventional labor management with additional TPU examination. A total of 45 2D B-mode TPU acquisitions were performed at different FHS, before performing DVE. The FHS was assessed by the algorithm (FHSaut) on TPU images and by DVE (FHSdig). The sonographic assessment of FHS by expert sonographer (FHSexp) on the same TPU acquisition used for the automatic measurement served as gold standard. The performance and accuracy were assessed through Spearman's ρ, the coefficient of determination (R2), root mean square error (RMSE), and Bland-Altman analysis.
RESULTS: A strong correlation between FHSaut and FHSexp (ρ = 0.97, p < 0.001) and a high coefficient of determination (R2 = 0.95) were found. A lower correlation with FHSexp (ρ = 0.66, p < 0.001) and coefficient of determination (R2 = 0.52) was found for DVE. Moreover, the RMSE reported higher accuracy of FHSaut (RMSE = 0.32 cm) compared to FHSdig (RMSE = 0.97 cm). Bland-Altman analysis showed that the algorithm performed with smaller bias and narrower limits of agreement compared to DVE.
CONCLUSION: The proposed algorithm can evaluate FHS with high accuracy and low RMSE. This approach could facilitate the use of US in labor, supporting the clinical staff in labor management.
引用
- Conversano F, Di Trani MG, Morello R, et al. Automated Approach for Enhancing Fetal Head Station Assessment in Labor with Transperineal Ultrasound. Ultrasound Med Biol. 2024. PMID: 39443217. doi:10.1016/j.ultrasmedbio.2024.09.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。