文献速递妇产影像技术与安全US

腹腔镜子宫切除术与腹腔镜子宫肌瘤剔除术前超声评分系统(PRESS-US)识别隐匿性平滑肌肉瘤的准确性

Preoperative identification from occult leiomyosarcomas in laparoscopic hysterectomy and laparoscopic myomectomy: accuracy of the ultrasound scoring system (PRESS-US).
PubMed 文献 · Radiol Med · 2024-10-30

该回顾性研究以组织学诊断为参考标准,评估基于超声的术前肉瘤评分(PRESS-US)在区分子宫平滑肌肉瘤与平滑肌瘤中的诊断效能及观察者间一致性。646例患者中14例(2.2%)为子宫平滑肌肉瘤,PRESS-US最佳截断值17.5时AUC为89.7%(95%CI 0.79-1.00),敏感度85.7%、特异度87.8%;低危与高危患者恶性率分别为0.35%和13.48%,不同经验放射科医师间一致性极好(κ=0.811,P<0.001)。

要点

  • PRESS-US最佳截断值17.5,区分子宫平滑肌肉瘤与平滑肌瘤的AUC为89.7%(95%CI 0.79-1.00)。
  • 敏感度85.7%、特异度87.8%,观察者间一致性极好(κ=0.811,P<0.001)。
  • 低危与高危患者恶性率分别为0.35%和13.48%,高危亚分组有助于更好风险分层。

核心结论

  • PRESS-US可为不同经验水平的放射科医师提供有效的子宫平滑肌肉瘤风险分层,可靠性高;对高危患者进行亚分组有助于更好的风险分层。

研究设计与样本

  • 回顾性评估因存在子宫肌瘤样肿块而接受手术及标准化超声检查的患者,以组织学诊断为参考标准,采用形态学子宫超声评估标准分析肿块,并用ROC曲线分析PRESS-US诊断准确性,κ统计评估低年资与专家放射科医师间一致性。

关键影像表现/征象

  • 共纳入646例患者,其中632例(97.8%)诊断为平滑肌瘤,14例(2.2%)为子宫平滑肌肉瘤。
  • 低危患者恶性率为0.35%,高危患者恶性率为13.48%。

诊断标准与关键数值

  • PRESS-US最佳截断值为17.5,AUC为89.7%(95%CI 0.79-1.00),敏感度85.7%,特异度87.8%。
  • 低年资与专家放射科医师间观察者间一致性极好(κ=0.811,P<0.001)。

临床应用与阅片要点

  • PRESS-US可用于术前超声评估子宫肌瘤样肿块,辅助区分子宫平滑肌肉瘤与平滑肌瘤。
  • 低危与高危患者恶性率分别为0.35%和13.48%,高危亚分组有助于更好风险分层。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic performance and inter-observer agreement of a PREoperative sarcoma scoring based on ultrasound (PRESS-US) in differentiating uterine leiomyosarcoma (uLMS) from leiomyoma (LM).

METHODS: We conducted a retrospective evaluation of patients who underwent surgery and received standardized ultrasound examinations due to the presence of uterine myoma-like masses. Histological diagnosis was used as the reference standard. The masses were analyzed using morphological uterus sonographic assessment criteria, and the diagnostic accuracy of PRESS-US was evaluated using ROC curve analysis. Kappa (κ) statistics were used to assess the inter-observer agreement between a less experienced and an expert radiologist.

RESULTS: Among the 646 patients, 632 (97.8%) were diagnosed with LM, and 14 (2.2%) had uLMS. The malignancy rates for low-risk and high-risk patients were 0.35% and 13.48%, respectively. The optimal PRESS-US cutoff was 17.5, resulting in an AUC of 89.7% (95% CI, 0.79-1.00), with a sensitivity of 85.7% and a specificity of 87.8%. The inter-observer agreement between a less experienced and an expert radiologist was excellent (κ = 0.811, P < 0.001).

CONCLUSIONS: PRESS-US provides effective risk stratification for uLMS for radiologists with different levels of experience, with high reliability. Subgrouping high-risk patients helps in better risk stratification.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Jiang Z, Jia S, Zhang J, et al. Preoperative identification from occult leiomyosarcomas in laparoscopic hysterectomy and laparoscopic myomectomy: accuracy of the ultrasound scoring system (PRESS-US). Radiol Med. 2024. PMID: 39476275. doi:10.1007/s11547-024-01903-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。