文献速递泌尿生殖技术与安全PETCT

基于[18F]PSMA-1007 PET/CT影像组学的端到端流程预测前列腺癌ISUP分级分组

End-to-end [18F]PSMA-1007 PET/CT radiomics-based pipeline for predicting ISUP grade group in prostate cancer.
PubMed 文献 · Abdom Radiol (NY) · 2024-09-30

回顾性纳入356例经组织病理学确诊的前列腺癌患者,基于[18F]PSMA-1007 PET/CT自动分割前列腺提取影像组学特征,构建30个模型预测ISUP分级分组(1-3 vs 4-5)。最佳影像组学模型在独立测试集上AUC为0.861,优于临床模型AUC 0.750(p=0.002),该端到端流程是预测ISUP分级分组的有效无创工具。

要点

  • 最佳影像组学模型在独立测试集AUC 0.861,优于临床模型AUC 0.750(p=0.002)。
  • 临床模型仅纳入年龄、tPSA、SUVmax和前列腺体积,预测效能低于影像组学模型。
  • 影像组学特征提取自PET/CT图像上自动分割的整个前列腺。

核心结论

  • 基于[18F]PSMA-1007 PET/CT的端到端影像组学流程是预测前列腺癌ISUP分级分组的有效无创工具。

研究设计与样本

  • 回顾性研究,纳入356例经组织病理学确诊的前列腺癌患者,训练集241例、独立测试集115例,均行[18F]PSMA-1007 PET/CT扫描,以ISUP分级分组(1-3 vs 4-5)为参考标准,结合6种特征选择算法与5种机器学习分类器构建30个模型。

诊断标准与关键数值

  • 按ISUP分级分组将患者分为1-3组与4-5组两类。
  • 最佳影像组学模型训练集AUC 0.879 ± 0.041、bAcc 0.745 ± 0.074,临床模型训练集AUC 0.799 ± 0.051、bAcc 0.629 ± 0.045。
  • 独立测试集最佳影像组学模型AUC 0.861、bAcc 0.764,临床模型AUC 0.750、bAcc 0.582,AUC比较p=0.002(Delong)、bAcc比较p=0.043(McNemar)。
  • 临床模型纳入年龄、tPSA、SUVmax和前列腺体积。

临床应用与阅片要点

  • 影像组学特征提取自PET/CT图像上自动分割的整个前列腺。
  • 学习曲线、校准曲线和DCA显示模型拟合良好并在临床实践中带来改善的获益。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop an end-to-end radiomics-based pipeline for the prediction of International Society of Urological Pathology grade group (ISUP GG) in prostate cancer (PCa).

METHODS: This retrospective study includes 356 patients (241 in training set and 115 in independent test set) with histopathologically confirmed PCa who underwent [18F]PSMA-1007 PET/CT scan. Patients were classified into two groups according to their ISUP GG (1-3 vs. 4-5). Radiomics features were extracted from the whole, automatically segmented prostate on PET/CT images, 30 models were constructed by combining 6 feature selection algorithms and 5 machine learning classifiers. The clinical model incorporated age, total prostate-specific antigen (tPSA), maximum standardized uptake value (SUVmax), and prostate volume. The predictive performance of the models was evaluated using the area under the receiver operating characteristic curve (AUC), balanced accuracy (bAcc), and decision curve analysis (DCA).

RESULTS: The best-performing radiomics model significantly outperformed clinical model (AUC 0.879 ± 0.041 vs. 0.799 ± 0.051, bAcc 0.745 ± 0.074 vs. 0.629 ± 0.045). On an external independent test set, best-performing radiomics model perform better than clinical model, with an AUC of 0.861 vs. 0.750, p = 0.002 (Delong), and bAcc of 0.764 vs. 0.582, p = 0.043 (McNemar). The learning curve, calibration curve and DCA demonstrated goodness-of-fit and improved benefits in clinical practice.

CONCLUSION: The end-to-end radiomics-based pipeline is an effective non-invasive tool to predict ISUP GG in PCa.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Yang F, Wang C, Shen J, et al. End-to-end [18F]PSMA-1007 PET/CT radiomics-based pipeline for predicting ISUP grade group in prostate cancer. Abdom Radiol (NY). 2024. PMID: 39349643. doi:10.1007/s00261-024-04601-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。