文献速递技术与安全PETCT

深度学习弹性配准算法改善常规肿瘤PET/CT配准伪影与图像质量的临床初步研究

Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT.
PubMed 文献 · Acad Radiol · 2024-10-28

回顾性纳入30例常规肿瘤检查患者(20例18F-FDG PET/CT和10例64Cu-DOTATATE PET/CT),比较未修改CTAC与深度学习增强空间变换CT衰减图的图像质量和SUV差异。深度学习衰减校正方法图像质量评分更高、配准伪影更少,信噪比指标显著改善,对采集时间更长的PET扫描影响更大。

要点

  • 深度学习弹性配准可减少PET与CTAC间的配准伪影,18F-FDG与64Cu-DOTATATE图像质量评分均提高。
  • 肝脏上部SUVmean在18F-FDG和64Cu-DOTATATE中分别变化5.3±4.9%和8.2±4.1%。
  • 肝肺指数(HPI)在18F-FDG为4.5±1.2 vs 4.0±1.1(P<0.001),在64Cu-DOTATATE为16.4±16.9 vs 12.5±5.5(P=0.039)。

核心结论

  • 深度学习弹性配准用于常规肿瘤PET/CT的CT衰减校正图可减少配准伪影,对采集时间更长的PET扫描影响更大。

研究设计与样本

  • 回顾性识别30例接受常规肿瘤检查的患者,包括20例18F-FDG PET/CT和10例64Cu-DOTATATE PET/CT,比较未修改CTAC与深度学习增强空间变换CT衰减图。

诊断标准与关键数值

  • 由三名放射科医师使用改良Likert量表对六个解剖部位进行图像质量主观评分;18F-FDG的DL质量评分为3.5-3.8 vs 标准重建3.2-3.5,64Cu-DOTATATE的DL质量评分为3.2-3.4 vs 标准重建2.1-3.3,除64Cu-DOTATATE脾脏下部外P<0.05。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Misregistration artifacts between the PET and attenuation correction CT (CTAC) exams can degrade image quality and cause diagnostic errors. Deep learning (DL)-warped elastic registration methods have been proposed to improve misregistration errors.

MATERIALS AND METHODS: 30 patients undergoing routine oncologic examination (20 18F-FDG PET/CT and 10 64Cu-DOTATATE PET/CT) were retrospectively identified and compared using unmodified CTAC, and a DL-augmented spatial transformation CT attenuation map. Primary endpoints included differences in subjective image quality and standardized uptake values (SUV). Exams were randomized to reduce reader bias, and three radiologists rated image quality across six anatomic sites using a modified Likert scale. Measures of local bias and lesion SUV were also quantitatively evaluated.

RESULTS: The DL attenuation correction methods were associated with higher image quality and reduced misregistration artifacts (Mean 18F-FDG quality rating=3.5-3.8 for DL vs 3.2-3.5 for standard reconstruction (STD); Mean 64Cu-DOTATATE quality rating= 3.2-3.4 for DL vs 2.1-3.3; P < 0.05 for STD, for all except 64Cu-DOTATATE inferior spleen). Percent change in superior liver SUVmean for 18F-FDG and 64Cu-DOTATATE were 5.3 ± 4.9 and 8.2 ± 4.1%, respectively. Measures of signal-to-noise ratio were significantly improved for the DL over STD (Hepatopulmonary index (HPI) [18F-FDG] = 4.5 ± 1.2 vs 4.0 ± 1.1, P < 0.001; HPI [64Cu-DOTATATE] = 16.4 ± 16.9 vs 12.5 ± 5.5, P = 0.039).

CONCLUSION: Deep learning elastic registration for CT attenuation correction maps on routine oncology PET/CT decreases misregistration artifacts, with a greater impact on PET scans with longer acquisition times.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chamberlin JH, Schaefferkoetter J, Hamill J, et al. Clinical Pilot of a Deep Learning Elastic Registration Algorithm to Improve Misregistration Artifact and Image Quality on Routine Oncologic PET/CT. Acad Radiol. 2024. PMID: 39462735. doi:10.1016/j.acra.2024.09.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。