磁共振弹性成像与常用无创检查组合评估肝胆肿瘤患者重度肝纤维化的比较
本回顾性研究纳入81例肝切除术前患者,比较磁共振弹性成像(MRE)肝硬度测量(LSM)与基于Gd-EOB-DTPA增强MRI的肝脾信号强度比(LSR)、CT脾体积/体表面积(SV/BSA)及IV型胶原7S等无创指标组合对重度肝纤维化(F3-4)的评估准确性。多因素分析显示LSR、SV/BSA和IV型胶原7S与重度肝纤维化相关,三者联合的AUC为0.95,显著高于LSM单独的0.85(p=0.04)。结论认为常用术前无创检查联合评估比单独MRE更准确。
要点
- LSR、SV/BSA与IV型胶原7S联合评估重度肝纤维化的AUC为0.95,显著高于LSM单独的0.85(p=0.04)。
- 多因素分析中LSR(OR 0.14)、SV/BSA(OR 1.25)和IV型胶原7S(OR 1.84)与重度肝纤维化独立相关。
- 常用术前无创检查组合比单独MRE更准确地评估肝胆肿瘤患者重度肝纤维化。
核心结论
- 联合LSR、SV/BSA和IV型胶原7S评估重度肝纤维化比单独MRE更准确。
研究设计与样本
- 回顾性研究纳入81例肝切除术前患者(平均年龄67岁±9.9,58例男性),均行MRE、Gd-EOB-DTPA增强MRI和动态CT检查。
关键影像表现/征象
- MRE测量肝硬度(LSM),Gd-EOB-DTPA增强MRI测量肝脾信号强度比(LSR),CT体积测量计算脾体积/体表面积(SV/BSA)。
- 实验室检查包括IV型胶原7S和透明质酸水平。
诊断标准与关键数值
- 重度肝纤维化定义为F3-4。
- LSR评估重度肝纤维化的OR为0.14(95%CI 0.05-0.37,p<0.001)。
- SV/BSA评估重度肝纤维化的OR为1.25(95%CI 1.02-1.52,p=0.03)。
- IV型胶原7S评估重度肝纤维化的OR为1.84(95%CI 1.12-3.00,p=0.02)。
- LSR、SV/BSA和IV型胶原7S联合评估重度肝纤维化的AUC为0.95,显著高于LSM单独的0.85(p=0.04)。
临床应用与阅片要点
- 在术前肝胆肿瘤患者中,可结合Gd-EOB-DTPA增强MRI的LSR、CT的SV/BSA和血IV型胶原7S来评估重度肝纤维化。
- 联合三项常用无创指标比单独MRE肝硬度测量更准确。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the accuracy of combined imaging and blood test indices related to liver fibrosis (LF) compared to magnetic resonance elastography (MRE) for estimating severe LF (F3-4) in preoperative patients.
METHODS: This retrospective study included patients who underwent MRE, gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI, and dynamic CT before liver resection. Liver stiffness measurement (LSM) using MRE, liver-to-spleen signal intensity ratio (LSR) using Gd-EOB-DTPA-enhanced MRI, and spleen volume normalized to body surface area (SV/BSA) using CT volumetry were measured. Laboratory parameters, including levels of type IV collagen 7S and hyaluronic acid, were also measured. Logistic regression and receiver operating characteristic analyses were performed to identify parameters that could estimate severe LF more accurately than LSM alone.
RESULTS: A total of 81 patients (mean age, 67 years ± 9.9 [SD]; 58 men) were enrolled. Multivariable logistic regression analysis indicated that LSR (odds ratio [OR]: 0.14, 95% confidence interval [CI]: 0.05-0.37, p < 0.001), SV/BSA (OR: 1.25, 95% CI: 1.02-1.52, p = 0.03) and type IV collagen 7S (OR: 1.84, 95% CI: 1.12-3.00, p = 0.02) were associated with severe LF. Receiver operating characteristic analysis showed that for estimating severe LF, the area under the curve was significantly larger for the combination of LSR, SV/BSA, and type IV collagen 7S than for LSM alone (0.95 vs 0.85, p = 0.04).
CONCLUSION: The combined evaluation of LSR, SV/BSA, and type IV collagen 7S obtained by clinically common preoperative examinations was more accurate than MRE alone for estimating severe LF in preoperative patients.
KEY POINTS: Question What indicators among the imaging and blood tests commonly performed preoperatively can provide a more accurate estimate of severe LF compared to MRE? Findings The combination of LSR, SV/BSA, and type IV collagen 7S was more accurate than an LSM alone for estimating severe LF. Clinical relevance A combination of commonly performed non-invasive preoperative tests provides a more accurate estimation of severe LF than MR elastography, an examination with relatively limited.
引用
- Nakazawa Y, Okada M, Tago K, et al. MR elastography vs a combination of common non-invasive tests for estimation of severe liver fibrosis in patients with hepatobiliary tumors. Eur Radiol. 2024. PMID: 39349724. doi:10.1007/s00330-024-11086-8