文献速递腹部泌尿生殖CT

CT定量参数鉴别肾上腺乏脂性腺瘤与结节性增生的可行性研究

Differentiate adrenal lipid-poor adenoma from nodular hyperplasia with CT quantitative parameters: a feasibility study.
PubMed 文献 · Abdom Radiol (NY) · 2024-10-19

回顾性纳入128例(乏脂性腺瘤83例、结节性增生45例)肾上腺切除术前行动脉期和门静脉期增强CT的患者,评估门静脉期衰减、绝对强化、相对强化、体积比及病灶数目。门静脉期衰减、体积比和病灶数目为乏脂性腺瘤的独立预测因子,联合模型AUC 0.835、敏感度73.5%、特异度80.0%,放射科医师诊断特异度和准确度似乎低于模型。

要点

  • 门静脉期衰减、体积比和病灶数目是乏脂性腺瘤的独立预测因子。
  • 联合CTp、体积比和病灶数目的Logistic模型AUC 0.835,敏感度73.5%、特异度80.0%。
  • 放射科医师主观评估的特异度和准确度似乎低于模型,读者间一致性0.082~0.535。

核心结论

  • 门静脉期CT在鉴别乏脂性腺瘤与结节性增生方面显示出潜力,联合CTp、体积比和病灶数目的模型在变异性和可重复性方面诊断表现优于放射科医师。

研究设计与样本

  • 回顾性分析肾上腺切除术前行动脉期和门静脉期增强CT的乏脂性腺瘤或结节性增生患者128例(乏脂性腺瘤83例、结节性增生45例),计算绝对强化、相对强化和相对强化比,用ITK-snap软件测量病灶体积及体积比,采用Student t检验和卡方检验比较组间差异,建立Logistic回归模型并构建ROC曲线。

诊断标准与关键数值

  • 门静脉期衰减、体积比和病灶数目为乏脂性腺瘤的独立预测因子。
  • 联合CTp、体积比和病灶数目的Logistic回归模型AUC 0.835,敏感度73.5%,特异度80.0%。
  • 放射科医师读者间一致性范围0.082~0.535,两名放射科医师的读者内一致性分别为0.734和0.583。

临床应用与阅片要点

  • 作者结论认为门静脉期CT在鉴别乏脂性腺瘤与结节性增生方面显示出潜力。
  • 作者结论认为联合CTp、体积比和病灶数目的模型在变异性和可重复性方面诊断表现优于放射科医师。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the potential of CT quantitative parameters in differentiating adrenal lipid-poor adenoma (LPA) from nodular hyperplasia and evaluate diagnostic performance.

MATERIALS AND METHODS: Patients with LPA or nodular hyperplasia who underwent contrast-enhanced CT before adrenalectomy were analyzed retrospectively. The study included 128 patients (83 with LPA and 45 with nodular hyperplasia). Each lesion's unenhanced attenuation, portal-venous phase attenuation (CTp), and the portal-venous phase attenuation of the abdominal aorta were evaluated. We subsequently calculated absolute enhancement [a lesion's portal-venous phase attenuation minus unenhanced attenuation (in HUs)], relative enhancement (absolute enhancement divided by unenhanced attenuation), and the relative enhancement ratio [(absolute enhancement divided by abdominal aorta's portal-venous phase attenuation) ×100%]. Lesion number and size were recorded. Volume was assessed by ITK-snap software and the ratio of lesion volume to ipsilateral adrenal volume (volume ratio) was determined. Intergroup differences were analyzed using Student's t-test and chi-squared test. Logistic regression models were developed, and receiver operating characteristic (ROC) curves were constructed to determine the area under the ROC curve (AUC), sensitivity, and specificity. The model's performance was then compared against radiologists' subjective assessments, and the inter- and intra-reader agreement values among radiologists were calculated.

RESULTS: Portal-venous phase attenuation, volume ratio, and lesion number were independent predictors of LPA. The logistic regression model incorporating CTp, volume ratio, and lesion number achieved an AUC of 0.835, with a sensitivity of 73.5% and a specificity of 80.0%. The radiologists' diagnostic specificity and accuracy appeared to be inferior to the model. The inter-reader agreement among radiologists ranged from 0.082 to 0.535, and the intra-reader agreement of two radiologists were 0.734 and 0.583.

CONCLUSION: The portal-venous phase CT demonstrated potential in distinguishing LPA from nodular hyperplasia. The diagnostic performance of the model integrating CTp, volume ratio, and lesion number outperformed radiologists in terms of variability and reproducibility.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bai X, Xu L, Zhang X, et al. Differentiate adrenal lipid-poor adenoma from nodular hyperplasia with CT quantitative parameters: a feasibility study. Abdom Radiol (NY). 2024. PMID: 39425754. doi:10.1007/s00261-024-04642-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。