文献速递腹部外周血管介入MRDSA

基于四维血流MRI的计算流体动力学模拟用于肝硬化经颈静脉肝内门体分流术患者无创门体压力梯度评估

Four-dimensional Flow MRI-based Computational Fluid Dynamics Simulation for Noninvasive Portosystemic Pressure Gradient Assessment in Patients with Cirrhosis and Transjugular Intrahepatic Portosystemic Shunt.
PubMed 文献 · Radiology · 2024-01-01

这项前瞻性研究纳入20例肝硬化合并经颈静脉肝内门体分流术(TIPS)患者,采用四维血流MRI结合计算流体动力学模拟无创评估门体压力梯度(PSPG),并与侵入性静脉造影测压对照。无创估测值与侵入性测值强相关(r=0.77;P < .001),对TIPS术后PSPG大于12 mm Hg的正确分类为16/20例(80%)。

要点

  • 四维血流MRI联合计算流体动力学可在肝硬化TIPS患者中无创估测门体压力梯度。
  • 无创估测值与侵入性静脉造影测值强相关(r=0.77;P < .001)。
  • 对TIPS术后PSPG大于12 mm Hg的正确分类为16/20例(80%)。

核心结论

  • 四维血流MRI联合计算流体动力学在肝硬化、门静脉高压及TIPS患者中用于无创门体压力梯度评估是可行的。

研究设计与样本

  • 前瞻性研究,2019年1月至2020年9月纳入20例肝硬化合并TIPS患者(平均年龄58岁±9[SD],11例男性),行腹部四维血流MRI并以侵入性静脉造影测压为参考标准。

关键影像表现/征象

  • 基于四维血流MRI的计算流体动力学模拟可显示分割血管及TIPS内的血流速度与压力分布。
  • 在TIPS和下腔静脉内测量流量,并将门静脉、TIPS、右肝静脉和下腔静脉分割后构建计算流体动力学网格。
  • 以门静脉和肝下下腔静脉作为四维血流MRI流量的流入端,肝上上腔静脉作为流出端。

诊断标准与关键数值

  • 无创门体压力梯度估测值定义为模拟的门静脉压力与肝上上腔静脉压力之差。
  • 无创估测值与侵入性测值的相关系数r=0.77(P < .001)。
  • 对TIPS术后门体压力梯度大于12 mm Hg的正确分类为16/20例(80%)。

临床应用与阅片要点

  • 四维血流MRI联合计算流体动力学模拟可用于无创估测门体压力梯度,辅助识别TIPS难治性门静脉高压。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction in patients with liver cirrhosis and recurrent symptoms of portal hypertension is primarily assessed with US and confirmed with invasive catheter venography, which can be used to measure the portosystemic pressure gradient (PSPG) to identify TIPS-refractory portal hypertension. To avoid the risks and costs of invasive catheter venography, noninvasive PSPG evaluation strategies are needed. Purpose To demonstrate the feasibility of the combination of four-dimensional (4D) flow MRI with computational fluid dynamics (CFD) for noninvasive PSPG assessment in participants with cirrhosis and TIPS. Materials and Methods Abdominal 4D flow MRI was performed prospectively in participants with cirrhosis and TIPS between January 2019 and September 2020. Flow rates were measured within the TIPS and inferior vena cava (IVC). The portal vein (PV), TIPS, right hepatic vein, and IVC were segmented on MRI scans to create a CFD mesh. The PV and infrahepatic IVC were defined as inflows for 4D flow MRI-derived flow rates. The suprahepatic IVC was defined as the outflow. CFD simulations were used to noninvasively estimate PSPG as the difference between the simulated pressures in the PV and suprahepatic IVC. Invasive venographic measurements of the PSPG served as the reference standard, and Pearson correlation analysis was conducted to evaluate the relationship between noninvasive estimates and invasive measurements. Results In all 20 participants with cirrhosis (mean age, 58 years ± 9 [SD]; 11 men), 4D flow MRI-based CFD simulations enabled visualization of flow velocities and pressure distributions within the segmented vasculature and TIPS. Noninvasive estimates and invasive measures of PSPG were strongly correlated (r = 0.77; P < .001). The 4D flow MRI-based CFD simulations correctly classified the presence or absence of a post-TIPS PSPG greater than 12 mm Hg in 16 of 20 participants (80%). Conclusion The combination of 4D flow MRI and CFD was feasible for noninvasive PSPG assessment in participants with cirrhosis, portal hypertension, and TIPS. © RSNA, 2024 See also the editorial by Motosugi and Watanabe in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Riedel C, Hoffmann M, Ismahil M, et al. Four-dimensional Flow MRI-based Computational Fluid Dynamics Simulation for Noninvasive Portosystemic Pressure Gradient Assessment in Patients with Cirrhosis and Transjugular Intrahepatic Portosystemic Shunt. Radiology. 2024. PMID: 39352287. doi:10.1148/radiol.232989

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。