两种不同仪器二维剪切波弹性成像在肝细胞癌患者中的比较
前瞻性纳入2022年10月至2023年9月290例肝细胞癌患者和30名健康志愿者,用AixPlorer V(SEmean)和APLIO i900(CEmean)行二维剪切波弹性成像,比较两种仪器测值及评估肝纤维化分期的影响因素。两种仪器测值差异显著(P < .001),但差异仅见于F4期肝纤维化患者(P < .001),健康志愿者及F0-F3期患者未见显著差异(均P > .050)。多因素线性回归显示,影响SEmean的独立因素为丙氨酸氨基转移酶(ALT)(P = .034)和肝纤维化分期(P < .001),而影响CEmean的仅为纤维化分期(P = .028)。
要点
- 两种仪器二维剪切波弹性成像测值差异显著(P < .001),但差异仅见于F4期肝纤维化患者(P < .001)。
- 健康志愿者及F0-F3期肝纤维化患者中,两种仪器测值未见显著差异(均P > .050)。
- ALT是影响AixPlorer V测值(SEmean)的独立因素(P = .034),肝纤维化分期是影响APLIO i900测值(CEmean)的唯一独立因素(P = .028)。
核心结论
- 两种不同仪器的二维剪切波弹性成像均能检测肝纤维化,但在肝细胞癌患者中测值存在差异,差异主要见于F4期肝纤维化患者,健康成人及F0-F3期患者中未见差异;ALT水平可能是导致仪器间差异的因素之一。
研究设计与样本
- 前瞻性研究,纳入2022年10月至2023年9月290例肝细胞癌患者和30名健康志愿者,分别用AixPlorer V(测值SEmean)和APLIO i900(测值CEmean)行二维剪切波弹性成像,比较两种仪器评估肝纤维化分期的测值并分析影响因素。
诊断标准与关键数值
- 两种仪器二维剪切波弹性成像测值差异显著(P < .001),但差异仅见于F4期肝纤维化患者(P < .001),健康志愿者及F0-F3期肝纤维化患者均未见显著差异(均P > .050)。
- 多因素线性回归显示,影响SEmean的独立因素为ALT(P = .034)和肝纤维化分期(P < .001),影响CEmean的独立因素仅为纤维化分期(P = .028)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to investigate and compare 2-dimensional shear wave elastography (2D-SWE) measurements and influencing factors among 2 different devices and to evaluate the ability and influencing factors of these measurements to assess liver fibrosis.
METHODS: From October 2022 to September 2023, 290 hepatocellular carcinoma (HCC) patients and 30 healthy volunteers were prospectively included. The 2D-SWE measurements were performed using AixPlorer V (SEmean) and APLIO i900 (CEmean). This study compared 2D-SWE measurements between instruments for evaluating the liver fibrosis stage and analyzed the potential influencing factors.
RESULTS: The 2D-SWE measurements obtained by the 2 instruments were significantly different (P < .001), but the differences were significant only for patients with stage F4 liver fibrosis (P < .001) and not for volunteers or patients with stage F0-F3 liver fibrosis (all P > .050). Multivariate linear regression analysis revealed that the factors independently influencing the SEmean were alanine aminotransferase (ALT) (P = .034) and liver fibrosis stage (P < .001), while fibrosis stage (P = .028) was the only factor influencing the CEmean.
CONCLUSIONS: Although 2D-SWE from the 2 different instruments was capable of detecting liver fibrosis, it yielded varying results in HCC patients. These discrepancies were predominantly observed in patients with F4 liver fibrosis but not in healthy adults or patients with F0-F3 liver fibrosis. One potential contributing factor to the differences between instruments could be ALT levels.
引用
- Huang J, Zhang X, Su L, et al. Comparison of Two-Dimensional Shear Wave Elastography Between Two Different Instruments for Hepatocellular Carcinoma Patients. J Ultrasound Med. 2024. PMID: 39400409. doi:10.1002/jum.16597
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。