深度学习CT重建对低密度肝脏病灶可检测性的体模与患者研究
单中心回顾性研究纳入50例门静脉期腹部CT患者的86个肝脏病灶及同一协议扫描的低对比分辨率体模,比较深度学习图像重建(DLIR)与40%强度自适应统计迭代重建-V(ASIR-V 40)对低对比病灶可检测性的影响。定性指标在DLIR与ASIR-V 40间未检测到差异(P > .05),DLIR中、高强度重建的病灶-背景对比噪声比高于ASIR-V 40,低对比病灶衰减降低2.8-3.6 HU。
要点
- DLIR低、中、高强度与ASIR-V 40在患者和体模研究中对低对比肝脏病灶的可检测性相似。
- DLIR中强度与高强度重建的病灶-背景对比噪声比高于ASIR-V 40(OR分别为1.96和5.36,P < .001)。
- DLIR重建使低对比病灶衰减降低2.8-3.6 HU,阅片时需注意病灶密度测量可能受影响。
核心结论
- 在患者和体模研究中,低、中、高强度DLIR与ASIR-V 40重建的CT对低对比肝脏病灶的可检测性相似;DLIR中、高强度重建的病灶-背景对比噪声比高于ASIR-V 40。
研究设计与样本
- 单中心回顾性研究,纳入2021年2月至5月行门静脉期腹部CT的患者50例(中位年龄62岁,IQR 57-73岁;女性27例[54%])及同一协议扫描的低对比分辨率体模,生成ASIR-V 40和三种强度DLIR共四种重建,由5名放射科医师定性评估。
诊断标准与关键数值
- 定性低对比可检测性指标在ASIR-V 40与DLIR间未检测到差异(P > .05);中强度DLIR vs ASIR-V 40的病灶-背景对比噪声比OR为1.96(95%CI 1.65, 2.33),高强度DLIR vs ASIR-V 40的OR为5.36(95%CI 3.68, 7.82),P < .001;DLIR使低对比病灶衰减降低2.8-3.6 HU;读者间一致性为中等至很好;病灶大小>1 cm与≤1 cm亚组分析结果相似(P > .05)。
临床应用与阅片要点
- DLIR中、高强度重建可提高病灶-背景对比噪声比,但定性低对比可检测性与ASIR-V 40相似,且DLIR使低对比病灶衰减降低2.8-3.6 HU,阅片和报告时需结合重建强度判断病灶密度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background CT deep learning image reconstruction (DLIR) improves image quality by reducing noise compared with adaptive statistical iterative reconstruction-V (ASIR-V). However, objective assessment of low-contrast lesion detectability is lacking. Purpose To investigate low-contrast detectability of hypoattenuating liver lesions on CT scans reconstructed with DLIR compared with CT scans reconstructed with ASIR-V in a patient and a phantom study. Materials and Methods This single-center retrospective study included patients undergoing portal venous phase abdominal CT between February and May 2021 and a low-contrast-resolution phantom scanned with the same protocol. Four reconstructions (ASIR-V at 40% strength [ASIR-V 40] and DLIR at three strengths) were generated. Five radiologists qualitatively assessed the images using the five-point Likert scale for image quality, lesion diagnostic confidence, conspicuity, and small lesion (≤1 cm) visibility. Up to two key lesions per patient, confirmed at histopathologic testing or at prior or follow-up imaging studies, were included. Lesion-to-background contrast-to-noise ratio was calculated. Interreader variability was analyzed. Intergroup qualitative and quantitative metrics were compared between DLIR and ASIR-V 40 using proportional odds logistic regression models. Results Eighty-six liver lesions (mean size, 15 mm ± 9.5 [SD]) in 50 patients (median age, 62 years [IQR, 57-73 years]; 27 [54%] female patients) were included. Differences were not detected for various qualitative low-contrast detectability metrics between ASIR-V 40 and DLIR (P > .05). Quantitatively, medium-strength DLIR and high-strength DLIR yielded higher lesion-to-background contrast-to-noise ratios than ASIR-V 40 (medium-strength DLIR vs ASIR-V 40: odds ratio [OR], 1.96 [95% CI: 1.65, 2.33]; high-strength DLIR vs ASIR-V 40: OR, 5.36 [95% CI: 3.68, 7.82]; P < .001). Low-contrast lesion attenuation was reduced by 2.8-3.6 HU with DLIR. Interreader agreement was moderate to very good for the qualitative metrics. Subgroup analysis based on lesion size of larger than 1 cm and 1 cm or smaller yielded similar results (P > .05). Qualitatively, phantom study results were similar to those in patients (P > .05). Conclusion The detectability of low-contrast liver lesions was similar on CT scans reconstructed with low-, medium-, and high-strength DLIR and ASIR-V 40 in both patient and phantom studies. Lesion-to-background contrast-to-noise ratios were higher for DLIR medium- and high-strength reconstructions compared with ASIR-V 40. © RSNA, 2024 Supplemental material is available for this article.