时间依赖性扩散MRI检测肝纤维化细胞微结构变化
这项前瞻性动物研究使用60只二乙基亚硝胺诱导的肝纤维化大鼠和5只对照大鼠,在3.0-T扫描仪上以5.4、10.7和69.3毫秒的等效扩散时间行时间依赖性扩散MRI,用IMPULSED模型估计细胞直径、细胞内体积分数(ICVF)、细胞密度和细胞外扩散率,并与组织病理学验证;结果显示细胞直径和ICVF与病理相关良好,是肝纤维化的可靠标志物。
要点
- 时间依赖性扩散MRI可无创定量肝纤维化进展中的细胞直径、ICVF和细胞密度等微结构参数。
- MRI测得细胞直径12.4-33.4 μm与病理11.4-35.4 μm高度相关(r=0.84,P<.001)。
- ICVF的MRI值0.23-0.85与病理0.28-0.89高度相关(r=0.62,P<.001),细胞直径和ICVF区分能力良好。
核心结论
- 本研究揭示了从肝纤维化到肝硬化全谱系的定量微结构成像变化,细胞直径、ICVF和细胞密度是肝纤维化的可靠标志物,其中细胞直径和ICVF表现出良好的区分能力。
研究设计与样本
- 前瞻性研究,2022年12月至2023年10月间用60只大鼠经二乙基亚硝胺给药建立肝纤维化模型,另设5只大鼠为对照动物,在3.0-T扫描仪上以等效扩散时间5.4、10.7和69.3毫秒行时间依赖性扩散MRI,采用IMPULSED模型估计微结构参数,并以组织病理学测量验证。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The potential of time-dependent diffusion MRI in imaging the progression from liver fibrosis to cirrhosis has not been established. Purpose To assess the effectiveness of time-dependent diffusion MRI in mapping the microstructure and characterizing cellular attributes during the progression of liver fibrosis to cirrhosis and to investigate its potential in grading liver fibrosis. Materials and Methods This prospective study, performed between December 2022 and October 2023, used 60 rats to establish a liver fibrosis model by means of diethylnitrosamine administration, with five additional rats serving as control animals. Time-dependent diffusion MRI was performed with equivalent diffusion time of 5.4, 10.7, and 69.3 msec on a 3.0-T scanner. Time-dependent diffusion MRI-based microstructural parameters, including cell diameter, intracellular volume fraction (ICVF), cellularity, and extracellular diffusivity, were estimated with use of the imaging microstructural parameters using limited spectrally edited diffusion, or IMPULSED, model. The fitted microstructural parameters were validated with histopathologic measurements. Results All 60 rats developed liver fibrosis, with a noticeable decrease in cell diameter and an increase in ICVF and cellularity observed as liver fibrosis progressed. The diameter measured at pathologic examination ranged from 11.4 μm to 35.4 μm, aligning with the range of 12.4-33.4 μm observed in time-dependent diffusion MRI, which indicated a strong correlation (r = 0.84; P < .001). The quantified ICVF at pathologic examination ranged from 0.28 to 0.89 and varied from 0.23 to 0.85 at time-dependent diffusion MRI, showing a high correlation (r = 0.62; P < .001). The cellularity observed at pathologic examination increased from 0.74 to 5.85, while the cellularity measured at time-dependent diffusion MRI ranged from 0.77 to 3.70, showing a correlation (r = 0.44; P < .001). Conclusion This study revealed the changes in quantitative microstructural mapping across the spectrum from liver fibrosis to cirrhosis. Cell diameter, ICVF, and cellularity are reliable markers for liver fibrosis, with diameter and ICVF presenting good discrimination ability. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Matos and Metens in this issue.
引用
- Zhang L, Long X, Chen L, et al. Detecting Cellular Microstructural Changes of Liver Fibrosis with Time-Dependent Diffusion MRI. Radiology. 2024. PMID: 39352282. doi:10.1148/radiol.240343
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。