文献速递腹部技术与安全CT

40-keV双能CT胰腺期图像采集优化触发阈值与传统触发阈值的随机对照试验

Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial.
PubMed 文献 · Abdom Radiol (NY) · 2024-10-21

前瞻性随机对照试验将69例接受胰腺方案双能CT检查的连续受试者分为传统触发阈值100 HU组(A组,34例)和优化触发阈值30 HU组(B组,35例),评估40-keV胰腺期图像扫描时机充分性。B组充分比例74.3%高于A组50.0%(P=0.049),优化触发阈值30 HU可获得更一致的充分胰腺期图像。

要点

  • 优化触发阈值30 HU组胰腺期图像扫描时机充分比例为74.3%,传统阈值100 HU组为50.0%(P=0.049)。
  • A组从30 HU至100 HU的中位时间差为4.5 s,触发后固定延迟20 s采集胰腺期。
  • 40-keV胰腺期图像上优化触发阈值可能改善胰腺病灶显示。

核心结论

  • 对于40-keV胰腺方案双能CT,优化触发阈值30 HU较传统触发阈值100 HU可获得更一致的充分胰腺期图像,可能改善胰腺病灶显示。

研究设计与样本

  • 前瞻性随机对照试验,纳入2021年9月至12月接受胰腺方案双能CT检查的连续受试者69例(中位年龄72岁),随机分为传统触发阈值100 HU组(A组,n=34)和优化触发阈值30 HU组(B组,n=35),触发后固定延迟20 s采集胰腺期图像,由两名放射科医师以二分类量表评估40-keV胰腺期图像扫描时机充分性。

诊断标准与关键数值

  • 扫描时机充分性以二分类量表(充分或不充分)评估40-keV胰腺期图像;A组充分50.0%、不充分50.0%,B组充分74.3%、不充分25.7%(P=0.049)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the impact of optimized trigger threshold on 40-keV pancreatic phase images acquired with a dual-energy CT (DECT) protocol.

METHODS: A cohort of 69 consecutive participants (median age, 72 years) undergoing a pancreatic protocol DECT examination between September to December 2021 were prospectively randomized into two protocols: conventional trigger threshold of 100 HU (Group A, n = 34) and optimized trigger threshold of 30 HU (Group B, n = 35). Pancreatic phase image acquisition was performed with fixed delay of 20 s from the trigger threshold. Two radiologists assessed the 40-keV pancreatic phase images for scan timing adequacy using a binary scale (adequate or inadequate). The proportions of these classifications were compared in the two groups using the Fisher's test.

RESULTS: The median times to achieve the aortic attenuation of 30 HU and 100 HU were 16.3 s and 22.3 s in Group A, respectively, and was 17.8 s for 30 HU in Group B. The median time difference from 30 HU to 100 HU was 4.5 s in Group A. The scan timing adequacies of pancreatic phase images were classified as adequate (50.0% and 74.3%) or inadequate (50.0% and 25.7%) in Group A and Group B (P = 0.049).

CONCLUSION: An optimized trigger threshold of 30 HU allows consistent acquisition of adequate pancreatic phase images compared to the conventional trigger threshold of 100 HU for pancreatic protocol DECT at 40-keV which might lead to improved pancreatic lesion conspicuity.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Noda Y, Koyasu H, Kambadakone A, et al. Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial. Abdom Radiol (NY). 2024. PMID: 39428423. doi:10.1007/s00261-024-04637-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。