文献速递心血管MRCT

5-T非对比Dixon全心冠状动脉MR血管成像的可行性与临床应用:一项前瞻性研究

Feasibility and Clinical Application of 5-T Noncontrast Dixon Whole-Heart Coronary MR Angiography: A Prospective Study.
PubMed 文献 · Radiology · 2024-01-01

前瞻性纳入8名志愿者和79例患者,比较5-T与3-T非对比全心冠状动脉MR血管成像,以冠状动脉CT血管成像为参考标准。5-T Dixon常规分辨率图像质量优于3-T序列,高分辨率5-T Dixon检测冠状动脉钙化的敏感度高于常规分辨率5-T Dixon(78.3% vs 53.3%),5-T Dixon常规分辨率诊断≥50%狭窄的准确率与3-T序列无显著差异。结论认为5-T非对比冠状动脉MR血管成像有潜力同时评估冠状动脉钙化和狭窄,诊断性能优于3-T。

要点

  • 5-T Dixon常规分辨率图像质量优于3-T SPAIR和3-T Dixon常规分辨率(P均<.001)。
  • 5-T Dixon高分辨率检测冠状动脉钙化的敏感度高于5-T Dixon常规分辨率(78.3% vs 53.3%),特异度无差异。
  • 5-T Dixon常规分辨率诊断≥50%狭窄的准确率与3-T序列无显著差异。

核心结论

  • 5-T非对比冠状动脉MR血管成像有潜力同时评估冠状动脉钙化和冠状动脉狭窄,诊断性能优于3-T。

研究设计与样本

  • 前瞻性研究,纳入8名志愿者和79例患者(平均年龄52岁±11,48名男性),2023年9月至2024年4月招募,患者以冠状动脉CT血管成像为参考标准。

关键影像表现/征象

  • 5-T Dixon常规分辨率图像质量高于3-T SPAIR常规分辨率和3-T Dixon常规分辨率(P均<.001)。
  • 5-T Dixon高分辨率图像质量与5-T Dixon常规分辨率相似(P=.60)。

诊断标准与关键数值

  • 5-T Dixon高分辨率检测冠状动脉钙化的每节段敏感度为78.3%,5-T Dixon常规分辨率为53.3%(P<.001);两者特异度均为98.6%(P>.99)。
  • 冠状动脉病变严重程度分级与冠状动脉CT血管成像的一致性:5-T Dixon常规分辨率κ=0.46,3-T SPAIR常规分辨率κ=0.13,3-T Dixon常规分辨率κ=0.55 vs 0.42。
  • 检测≥50%狭窄的每患者敏感度、特异度、准确率:5-T Dixon常规分辨率 vs 3-T SPAIR常规分辨率分别为88.9% vs 55.6%、86.5% vs 62.2%、87.0% vs 60.9%(P分别为.55、.01、.18)。
  • 检测≥50%狭窄的每患者敏感度、特异度、准确率:5-T Dixon常规分辨率 vs 3-T Dixon常规分辨率分别为90.0% vs 80.0%、86.8% vs 71.1%、87.5% vs 72.9%(P均>.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Coronary MR angiography (CMRA) at 3 T offers higher signal to noise ratio and contrast to noise ratio compared with 1.5 T. CMRA at 5 T may provide better diagnostic performance. Purpose To assess the feasibility and clinical application of 5-T noncontrast whole-heart CMRA and compare 5-T acquisition with 3-T acquisition. Materials and Methods From September 2023 to April 2024, patients scheduled for coronary CT angiography (CCTA) and volunteers were prospectively recruited. CCTA served as the reference standard in patients. CMRA was performed using a 3-T spectral attenuated inversion-recovery (3TSPAIR) sequence and 3-T Dixon (3TDixon) sequence with routine spatial resolution (3TSPAIR-routine and 3TDixon-routine, respectively), and 5-T Dixon (5TDixon) with routine and high spatial resolution (5TDixon-routine and 5TDixon-high, respectively). The study evaluated image quality, coronary artery calcium (CAC), the severity of coronary artery disease (CAD) graded according to Coronary Artery Disease Reporting and Data System, and the presence of ≥50% coronary stenosis. The nonparametric paired Wilcoxon signed rank test, McNemar test, generalized estimating equation model, and kappa test were used. Results Eight volunteers and 79 patients were included (mean age, 52 years ± 11 [SD]; 48 male). Image quality was higher for 5TDixon-routine compared with 3TSPAIR-routine and 3TDixon-routine (P < .001 for both) and similar for 5TDixon-high (P = .60). The per-segment sensitivity for CAC was higher at 5TDixon-high than 5TDixon-routine (78.3% vs 53.3%; P < .001), with no difference in specificity (98.6% vs 98.6%; P > .99). In grading the severity of CAD, 5TDixon-routine showed better consistency with CCTA than 3TSPAIR-routine (κ = 0.46 vs 0.13) and 3TDixon-routine (κ = 0.55 vs 0.42). For detecting ≥50% stenosis, the per-patient sensitivity, specificity, and accuracy were as follows: 5TDixon-routine versus 3TSPAIR-routine, 88.9% versus 55.6%, 86.5% versus 62.2%, and 87.0% versus 60.9% (P = .55, .01, and .18, respectively); 5TDixon-routine versus 3TDixon-routine, 90.0% versus 80.0%, 86.8% versus 71.1%, and 87.5% versus 72.9%, respectively (P > .05 for all). Conclusion Noncontrast CMRA at 5 T shows potential to evaluate CAC and coronary stenosis simultaneously and demonstrates superior diagnostic performance compared with at 3 T. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Rahsepar and Kim in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Lu H, Miao X, Wang D, et al. Feasibility and Clinical Application of 5-T Noncontrast Dixon Whole-Heart Coronary MR Angiography: A Prospective Study. Radiology. 2024. PMID: 39436288. doi:10.1148/radiol.240389

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。