基于多模态PET/CT参数预测浸润性肺腺癌侵袭性的列线图
该回顾性研究纳入113例浸润性肺腺癌患者,分析PET/CT多模态参数与分化程度、EGFR突变及Ki67指数的关系,构建了预测EGFR突变的PET/CT回归模型(AUC 0.820),并发现MTV和TLG在鉴别分化程度方面优于CT及其他PET参数。
要点
- 低分化组更常见大直径、实性病灶、胸膜牵拉征和空泡征(均P<0.05)。
- PET/CT回归模型预测EGFR突变AUC为0.820,敏感度84.74%、特异度70.37%。
- SUVpeak、MTV、TLG与Ki67指数升高强相关(r=0.580、0.662、0.680,均P<0.001)。
核心结论
- MTV和TLG较CT及其他PET参数能更好地鉴别浸润性肺腺癌的分化程度;基于多模态PET/CT参数构建的列线图能更好地动态监测EGFR状态和Ki67指数的变化。
研究设计与样本
- 回顾性收集113例接受PET/CT检查的浸润性肺腺癌患者,分析不同分化组间PET/CT多模态参数的差异,采用二元logistic回归建立预测EGFR突变的模型并用ROC曲线比较诊断效能,采用多元线性回归筛选Ki67指数的独立预测因素。
关键影像表现/征象
- 低分化组较其他组更易出现大直径、实性病灶、胸膜牵拉征和空泡征(均P<0.05)。
- 三个不同分化组间MTV和TLG差异与其他参数相比均有统计学意义(均P<0.05)。
- PET/CT多元线性回归分析显示血管集束征、SUVpeak、MTV和TLG可解释Ki67变化的62.0%(R²=0.620)。
诊断标准与关键数值
- PET/CT回归模型预测EGFR突变的AUC为0.820,高于其他模型。
- 该模型判别EGFR突变的敏感度84.74%、特异度70.37%、阳性预测值75.76%、阴性预测值80.85%。
- SUVpeak、MTV、TLG与Ki67指数升高强相关(r=0.580、r=0.662、r=0.680,均P<0.001)。
临床应用与阅片要点
- 阅片时可关注大直径、实性病灶、胸膜牵拉征和空泡征,这些征象在低分化组更常见(均P<0.05)。
- MTV和TLG对鉴别浸润性肺腺癌分化程度的价值优于CT及其他PET参数。
- 基于多模态PET/CT参数的列线图可用于动态监测EGFR状态和Ki67指数变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: We investigated the value of PET/CT-based multimodal parameters in predicting the degree of differentiation and epidermal growth factor receptor (EGFR) mutations in invasive lung adenocarcinoma (ILA) and assessed the correlation between PET/CT-based multimodal parameters and Ki67.
METHODS: We retrospectively collected 113 patients with ILA who underwent PET/CT examination, and differences in PET/CT multimodal parameters between different differentiation groups were analyzed. Binary logistic regression was used to establish a multiparameter model for predicting EGFR mutation, and ROC curve was used to compare the diagnostic efficiency. Independent predictors of the Ki67 index were screened using multiple linear regression analysis.
RESULTS: The poorly differentiated group was more likely to have large-diameter, solid foci, pleural pulling signs, and vacuolar signs compared with other groups (all P < 0.05). The differences in metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in all three different differentiated groups were statistically significant compared to the other parameters (all P < 0.05). The PET/CT regression model predicted EGFR mutations with an AUC of 0.820 and was higher than other models; the sensitivity, specificity, positive predictive value, and negative predictive value for discriminating EGFR mutations were 84.74%, 70.37%, 75.76%, and 80.85%, respectively. PET/CT multiple linear regression analysis showed that vascular convergence, SUVpeak, MTV, and TLG explaining 62.0% changes in Ki67 (R2 = 0.620). SUVpeak, MTV, and TLG (r = 0.580, r = 0.662, and r = 0.680, all P < 0.001) were all strongly correlated with increased Ki67 index.
CONCLUSION: MTV and TLG can better identify the degree of ILA differentiation compared to CT and other PET parameters. The nomogram constructed by multimodal PET/CT parameters can better dynamically monitor the changes of EGFR status and Ki67 index.
引用
- Ma N, Du H, Li J, et al. A Nomogram for the Prediction of Invasiveness in Invasive Pulmonary Adenocarcinoma on the Basis of Multimodal PET/CT Parameters. Acad Radiol. 2024. PMID: 39472205. doi:10.1016/j.acra.2024.10.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。