双能减影X线摄影(DESR):肺结节检测的系统综述与Meta分析
该系统综述与Meta分析检索PubMed,纳入1994至2022年间比较双能减影X线摄影(DESR)与常规X线摄影(CR)检测肺结节的23项研究(排除使用人工智能的研究)。DESR的ROC AUC均值0.7702、敏感度均值0.5753,分别高于CR的0.7106和0.4391(P<0.001);两者特异度均值分别为0.753和0.764,差异-0.011(P=0.767)无统计学意义。结论为DESR检测肺结节的敏感度和ROC AUC优于CR,特异度无差异。
要点
- DESR检测肺结节的ROC AUC均值0.7702 vs CR 0.7106,差值0.0597(P<0.001)。
- DESR敏感度均值0.5753 vs CR 0.4391,差值0.136(P<0.001)。
- DESR特异度均值0.753 vs CR 0.764,差值-0.011(P=0.767),无统计学显著差异。
核心结论
- DESR检测肺结节的敏感度和ROC AUC优于CR,特异度无差异。
研究设计与样本
- 系统综述与Meta分析,检索PubMed,纳入1994至2022年间比较DESR与CR检测肺结节的23项研究,排除使用人工智能的研究。
诊断标准与关键数值
- 23项研究中18项报告ROC AUC:DESR均值0.7702(SD=0.1361)vs CR均值0.7106(SD=0.1183),差值0.0597(P<0.001)。
- 23项研究中13项报告敏感度:DESR均值0.5753(SD=0.1546)vs CR均值0.4391(SD=0.1007),差值0.136(P<0.001)。
- 23项研究中10项报告特异度:DESR均值0.753(SD=0.1575)vs CR均值0.764(SD=0.1168),差值-0.011(P=0.767),无统计学显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study examined the literature to compare the accuracy, sensitivity, and specificity of dual-energy subtraction radiography (DESR) with conventional radiography (CR) in the detection of pulmonary nodules. To our knowledge, no meta-analysis has been conducted to compare DESR with CR.
MATERIAL AND METHODS: The authors searched Pubmed using the terms "Dual-energy subtraction radiography," and "Dual-Energy Chest Radiography." Only studies comparing the detection of pulmonary nodules between DESR and CR were included. Studies utilizing artificial intelligence were excluded. The primary study outcomes analyzed were the mean difference of receiver operating characteristic area under the curve (ROC AUC), mean difference of sensitivity, and mean difference of specificity.
RESULTS: Twenty-three studies between 1994 and 2022 were included. Of these twenty-three, eighteen reported ROC AUC statistics. The difference between DESR ROC AUC (mean = 0.7702, SD = 0.1361) and CR ROC AUC (mean = 0.7106, SD = 0.1183) was 0.0597 (P<0.001). Sensitivity data was reported for thirteen of the twenty-three selected studies. The difference between DESR sensitivity (mean = 0.5753, SD = 0.1546) and CR sensitivity (mean = 0.4391, SD = 0.1007) was 0.136 (P<0.001). Specificity data were reported for ten of the twenty-three selected studies. The difference between DESR specificity (mean = 0.753, SD = 0.1575) and CR specificity (mean = 0.764, SD = 0.1168) was -0.011 (P=0.767). This was not statistically significant.
CONCLUSIONS: DESR showed superior sensitivity and ROC AUC values compared with CR in detecting pulmonary nodules. There was no difference in specificity.