文献速递妇产影像儿科影像US

妊娠12周前胚胎与胎儿心脏发育的超声评估

Embryonic and Fetal Heart Development Before 12 Weeks of Gestation.
PubMed 文献 · J Ultrasound Med · 2024-10-21

研究对131例8至11+6周正常胎儿行经阴道二维超声检查,其中105例成功获得心脏基底-心尖长度、横向长度、心脏周长、胚胎心脏面积、整体球形指数及心胸面积比等参数并构建列线图。基底-心尖长度、横向长度、心脏周长及胚胎心脏面积随孕龄呈曲线增长,整体球形指数与心胸面积比在该孕周区间保持恒定。

要点

  • 8至11+6周经阴道超声可测量心脏基底-心尖长度、横向长度、心脏周长、胚胎心脏面积并构建列线图。
  • 整体球形指数均值1.14(SD 0.10)、心胸面积比均值15.7%(SD 3.3%)在8至11+6周保持恒定。
  • 基底-心尖长度、横向长度、心脏周长及胚胎心脏面积与头臀长呈显著曲线相关。

核心结论

  • 研究提供多个心脏参数的列线图,可能有助于增进对妊娠12周前胚胎与胎儿心脏生长发育的理解。

研究设计与样本

  • 研究为经阴道二维超声评估胚胎与胎儿心脏生长的观察性研究,对131例8至11+6周正常胎儿行早孕期孕龄测定扫查,其中105例正常胚胎与胎儿成功获得心脏参数。

关键影像表现/征象

  • 基底-心尖长度、横向长度、心脏周长及胚胎心脏面积随孕龄增加呈曲线增长(R²分别为0.97406、0.980396、0.978359、0.920705,P < .001)。
  • 整体球形指数(均值1.14,SD 0.10)与心胸面积比(均值15.7%,SD 3.3%)在8至11+6周保持恒定。
  • 基底-心尖长度、横向长度、心脏周长及胚胎心脏面积与头臀长呈显著曲线相关(R²分别为0.975976、0.983482、0.980673、0.929936,P < .001)。
  • 整体球形指数与心胸面积比在该孕周区间不随头臀长增加而变化。

诊断标准与关键数值

  • 构建了基底-心尖长度、横向长度、心脏周长、胚胎心脏面积、整体球形指数及心胸面积比的列线图。
  • 整体球形指数均值1.14(SD 0.10),心胸面积比均值15.7%(SD 3.3%),在8至11+6周恒定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess embryonic and fetal cardiac growth and development using transvaginal 2-dimensional sonography before 12 weeks of gestation.

METHODS: Transvaginal scans for first-trimester dating were performed for 131 normal fetuses at 8-11 + 6 weeks of gestation. The basal-apical length (BAL), transverse length (TL), cardiac circumference (ECC), embryonic cardiac area (ECA), global sphericity index (GSI), and cardio-thoracic area ratio (CTAR) were able to be obtained in 105 normal embryos and fetuses.

RESULTS: Nomograms for several cardiac parameters including BAL, TL, ECC, ECA, GSI, and CTAR were constructed. BAL, TL, ECC, and ECA increased curvilinearly with advancing gestation (R2 = 0.97406, 0.980396, 0.978359, and 0.920705, respectively, P < .001). GSI (mean, 1.14; SD, 0.10) and CTAR (mean, 15.7%; SD, 3.3%) values were constant at 8-11 + 6 weeks of gestation. There were significant curvilinear correlations between BAL, TL, ECC, and ECA, and crown-rump length (CRL) (R2 = 0.975976, 0.983482, 0.980673, and 0.929936, respectively, P < .001). GSI and CTAR values were not changed with the increase of CRL during this period.

CONCLUSION: Our results provide nomograms for several cardiac parameters which may improve the understanding of embryonic and fetal cardiac growth and development prior to 12 weeks of gestation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hata T, Konishi M, Koyanagi A, et al. Embryonic and Fetal Heart Development Before 12 Weeks of Gestation. J Ultrasound Med. 2024. PMID: 39431605. doi:10.1002/jum.16605

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。