回顾性分析24例成骨性转移瘤患者和56例骨岛患者的双能CT图像,共70个成骨性转移瘤和67个骨岛。CT70keV、钙水密度和水钙密度的AUC无显著差异;联合钙水密度与水钙密度在诊断一致的119个病灶中特异度92.1%,高于CT70keV的81.4%。

要点

  • 双能CT定量参数可用于鉴别肺癌患者成骨性转移瘤与骨岛。
  • CT70keV最佳阈值为885.1 HU,敏感度92.5%、特异度81.4%、准确率86.9%。
  • 钙水密度与水钙密度诊断一致时特异度92.1%,高于CT70keV。

核心结论

  • 联合钙水密度与水钙密度在鉴别肺癌患者成骨性转移瘤与骨岛方面显示出有前景的作用。

研究设计与样本

  • 回顾性分析2019年1月至2021年12月间24例成骨性转移瘤患者和56例骨岛患者的双能CT图像,共纳入70个成骨性转移瘤和67个骨岛。

诊断标准与关键数值

  • CT70keV、钙水密度和水钙密度的AUC分别为0.950、0.947和0.929,三者无显著差异(P>0.05);CT70keV最佳阈值为885.1 HU,特异度81.4%、敏感度92.5%、准确率86.9%;钙水密度<254.9 mg/cm3与水钙密度<1250.6 mg/cm3诊断一致的119个病灶中,特异度92.1%,高于CT70keV(P=0.021),AUC 0.974、敏感度92.9%、准确率92.4%,与CT70keV无显著差异(P分别为0.230、0.906、0.220)。

临床应用与阅片要点

  • 作者认为联合钙水密度与水钙密度在鉴别成骨性转移瘤与骨岛方面有前景;18个诊断不一致病灶中,钙水密度正确诊断11个,水钙密度正确诊断其余7个。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic efficacy of quantitative dual-energy computed tomography (CT) parameters for distinguishing osteoblastic metastases (OBMs) from bone islands (BIs) in untreated lung cancer.

MATERIAL AND METHODS: Dual-energy CT images of 24 patients with OBMs and 56 patients with BIs obtained between January 2019 and December 2021 were retrospectively analyzed. The CT70keV value, calcium(water) density [Dcalcium(water)], and water(calcium) density [Dwater(calcium)] were analyzed. Diagnostic performance was assessed by measuring the area under the curve (AUC), and specificity, sensitivity, and accuracy were determined.

RESULTS: A total of 70 OBMs and 67 BIs were included. The AUC values of CT70keV, Dcalcium(water), and Dwater(calcium) showed no significant differences (0.950 vs. 0.947 vs. 0.929, respectively; P > 0.05). The optimal CT70keV cutoff value was 885.1 HU, with specificity, sensitivity, and accuracy of 81.4 %, 92.5 %, and 86.9 %, respectively. When using Dcalcium(water) < 254.9 mg/cm3 and Dwater(calcium) < 1250.6 mg/cm3, respectively, 119 of 137 lesions showed consistent diagnostic results (true or false). Sub-analysis of these 119 lesions showed specificity of 92.1 %, which was higher than that of CT70keV (P = 0.021). The AUC, sensitivity, and accuracy were 0.974, 92.9 %, and 92.4 %, respectively, which were not significantly different from those of CT70keV (P = 0.230, 0.906, and 0.220, respectively). Among the 18 lesions showing inconsistent diagnoses, Dcalcium(water) diagnosed 11 lesions correctly, and Dwater(calcium) diagnosed the remaining seven lesions correctly.

CONCLUSION: The combination of Dcalcium(water) and Dwater(calcium) demonstrated a promising role in the differentiation of OBMs from BIs in lung cancer patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Cai L, Jiang N, et al. Differentiation of osteoblastic metastases and bone islands on dual-energy computed tomography in patients with untreated lung cancer. Eur J Radiol. 2024. PMID: 39393215. doi:10.1016/j.ejrad.2024.111770