文献速递骨肌技术与安全CTMR

双能CT虚拟去钙成像在多发性骨髓瘤影像诊断中的视觉评估与定量分析

Visual assessment and quantitative analysis of dual-energy CT virtual non-calcium in imaging diagnosis of multiple myeloma.
PubMed 文献 · Skeletal Radiol · 2024-10-08

研究纳入72例多发性骨髓瘤患者和10例对照,行双能CT虚拟去钙成像并与MRI对照分类骨髓浸润模式。虚拟去钙与MRI分类一致性高(kappa=0.944),骨髓浸润组虚拟去钙衰减值高于非浸润组和对照组,不同部位最佳截断值不同,诊断时应按部位选用相应阈值。

要点

  • 虚拟去钙成像与MRI对骨髓浸润模式分类的一致性高(kappa=0.944)。
  • 骨髓浸润组虚拟去钙衰减值高于非浸润组和对照组,总体最佳截断值为-42.2 HU。
  • 不同部位最佳截断值不同:颈椎-21.9 HU、胸椎-42.8 HU、腰椎-56.9 HU、骨盆-66.3 HU。

核心结论

  • 双能CT虚拟去钙成像与MRI在多发性骨髓瘤骨髓浸润模式分类上一致性良好,不同身体区域应使用不同的虚拟去钙衰减值截断值来诊断骨髓浸润。

研究设计与样本

  • 研究纳入72例多发性骨髓瘤患者和10例对照,患者接受双能CT和MRI检查,对照仅接受双能CT检查,覆盖颈椎、胸椎、腰椎和骨盆。

关键影像表现/征象

  • 虚拟去钙图像与MRI比较用于确认和模式分类,Fleiss Kappa分析评估虚拟去钙与MRI分类的一致性,Bland-Altman分析评估观察者间一致性。

诊断标准与关键数值

  • 骨髓浸润组虚拟去钙平均衰减值为-28.3 HU(95%CI -32.1至-24.6),高于非骨髓浸润组的-97.5 HU(95%CI -104.7至-90.3)和对照组的-89.1 HU(95%CI -95.1至-83.1;F=172.027,P<0.001)。总体最佳截断值为-42.2 HU,颈椎为-21.9 HU,胸椎为-42.8 HU,腰椎为-56.9 HU,骨盆为-66.3 HU。

临床应用与阅片要点

  • 虚拟去钙成像可用于多发性骨髓瘤骨髓浸润的影像诊断,阅片时应按身体区域选用相应的虚拟去钙衰减值截断值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the reliability and diagnostic performance of dual-energy CT virtual non-calcium imaging in diagnosing bone marrow infiltration in multiple myeloma.

MATERIALS AND METHODS: Seventy-two patients with multiple myeloma and ten controls were recruited. Patients received dual-energy CT and MRI while controls underwent dual-energy CT only, covering the cervical, thoracic, and lumbar spine and the pelvis. Virtual non-calcium images were compared with magnetic resonance images for confirmation and pattern classification. Fleiss Kappa analysis assessed consistency between virtual non-calcium and MRI classifications. Inter-observer agreement for virtual non-calcium and CT attenuation values was evaluated using Bland-Altman analysis. Diagnostic performances across various sites were evaluated using analysis of variance and receiver operating characteristic curve analysis.

RESULTS: Dual-energy CT achieved higher consistency in classifying bone marrow infiltration in multiple myeloma than did MRI (kappa = 0.944). In the overall analysis, the mean virtual non-calcium attenuation values in the bone marrow infiltration group (- 28.3 HU; 95% confidence interval (CI), - 32.1, - 24.6) were higher than those in the non-bone marrow infiltration (- 97.5 HU; 95% CI, - 104.7, - 90.3) and control (- 89.1 HU; 95% CI, - 95.1, - 83.1; F = 172.027, P < 0.001) groups. The optimal cutoff values for virtual non-calcium attenuation varied across the overall (- 42.2 HU), cervical spine (- 21.9 HU), thoracic spine (- 42.8 HU), lumbar spine (- 56.9 HU), and pelvis (- 66.3 HU).

CONCLUSION: Dual-energy CT virtual non-calcium imaging and MRI exhibited good consistency in categorising bone marrow infiltration patterns in multiple myeloma. Different virtual non-calcium attenuation value cutoffs should be used to diagnose bone marrow infiltration in various body regions.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Liang L, Xiao F, Liang L, et al. Visual assessment and quantitative analysis of dual-energy CT virtual non-calcium in imaging diagnosis of multiple myeloma. Skeletal Radiol. 2024. PMID: 39377813. doi:10.1007/s00256-024-04805-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。