文献速递胸部CT

低剂量全胸动态CT评估疑似气管支气管不稳患者的大气道塌陷性

Low-Dose Whole-Chest Dynamic CT for the Assessment of Large Airway Collapsibility in Patients with Suspected Tracheobronchial Instability.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

该回顾性研究分析52例疑似气管塌陷患者的低剂量四维CT,视觉评估将患者分为气管塌陷≥50%、<50%及固定狭窄三组,四维CT较配对吸气-呼气CT检出更多塌陷≥50%的患者(一致性41%,P<.001),且塌陷程度与FEV1%无相关性。

要点

  • 四维CT视觉评估检出气管塌陷≥50%的患者多于配对CT,一致性仅41%(P<.001)。
  • 四维CT与支气管镜检出一致性为74%(P=.39),四维CT检出更多塌陷≥50%的患者。
  • 气管塌陷程度与FEV1%无相关性(rs=-0.002至0.01,P=.99-.96)。

核心结论

  • 四维CT可行,对中央气道塌陷的检出可能比配对CT更敏感;FEV1%与气管塌陷严重程度不相关。

研究设计与样本

  • 回顾性分析2016年1月至2022年12月间52例疑似气管塌陷患者的低剂量四维CT(浅呼吸),平均年龄66岁±12岁,27例女性、25例男性,其中32例慢性阻塞性肺疾病患者(FEV1%均值50%±27);27例有配对CT数据,46例有支气管镜数据;两名放射科医师共识阅片,YACTA软件定量。

关键影像表现/征象

  • 四维CT上25/52(48%)患者气管塌陷≥50%,20/52(38%)<50%,7/52(13%)为固定狭窄。
  • 视觉评估塌陷≥50%组气管腔面积塌陷度53%±9、管腔体积塌陷度52%±10,<50%组分别为27%±9和26%±6(P<.001)。
  • 固定狭窄组气管面积和体积塌陷度分别为16%±12和21%±11,保持稳定。

诊断标准与关键数值

  • 四维CT视觉评估将患者分为气管塌陷≥50%、<50%或固定狭窄三组。
  • 四维CT视觉评估检出塌陷≥50%的患者多于配对CT,一致性41%(P<.001)。
  • 四维CT检出塌陷≥50%的患者多于支气管镜,一致性74%(P=.39)。

临床应用与阅片要点

  • 低剂量四维CT可用于评估疑似气管支气管不稳患者的大气道塌陷性。
  • 四维CT视觉评估较配对吸气-呼气CT检出更多气管塌陷≥50%的患者,阅片时需注意两种方法的一致性仅41%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To quantify tracheal collapsibility using low-dose four-dimensional (4D) CT and to compare visual and quantitative 4D CT-based assessments with assessments from paired inspiratory-expiratory CT, bronchoscopy, and spirometry. Materials and Methods The authors retrospectively analyzed 4D CT examinations (January 2016-December 2022) during shallow respiration in 52 patients (mean age, 66 years ± 12 [SD]; 27 female, 25 male), including 32 patients with chronic obstructive pulmonary disease (mean forced expiratory volume in 1 second percentage predicted [FEV1%], 50% ± 27), with suspected tracheal collapse. Paired CT data were available for 27 patients and bronchoscopy data for 46 patients. Images were reviewed by two radiologists in consensus, classifying patients into three groups: 50% or greater tracheal collapsibility, less than 50% collapsibility, or fixed stenosis. Changes in minimal tracheal lumen area, tracheal volume, and lung volume from inspiration to expiration were quantified using YACTA software. Tracheal collapsibility between groups was compared employing one-way analysis of variance (ANOVA). For related samples within one group, ANOVA with repeated measures was used. Spearman rank order correlation coefficient was calculated for collapsibility versus pulmonary function tests. Results At 4D CT, 25 of 52 (48%) patients had tracheal collapsibility of 50% or greater, 20 of 52 (38%) less than 50%, and seven of 52 (13%) had fixed stenosis. Visual assessment of 4D CT detected more patients with collapsibility of 50% or greater than paired CT, and concordance was 41% (P < .001). 4D CT helped identify more patients with tracheal collapsibility of 50% or greater than did bronchoscopy, and concordance was 74% (P = .39). Mean collapsibility of tracheal lumen area and volume at 4D CT were higher for 50% or greater visually assessed collapsibility (area: 53% ± 9 and lumen: 52% ± 10) compared with the less than 50% group (27% ± 9 and 26% ± 6, respectively) (P < .001), whereas both tracheal area and volume were stable for the fixed stenosis group (area: 16% ± 12 and lumen: 21% ± 11). Collapsibility of tracheal lumen area and volume did not correlate with FEV1% (rs = -0.002 to 0.01, P = .99-.96). Conclusion The study demonstrated that 4D CT is feasible and potentially more sensitive than paired CT for central airway collapse. Expectedly, FEV1% was not correlated with severity of tracheal collapsibility. Keywords: CT-Quantitative, Tracheobronchial Tree, Chronic Obstructive Pulmonary Disease, Imaging Postprocessing, Thorax Supplemental material is available for this article. © RSNA, 2024.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Bischoff A, Weinheimer O, Dutschke A, et al. Low-Dose Whole-Chest Dynamic CT for the Assessment of Large Airway Collapsibility in Patients with Suspected Tracheobronchial Instability. Radiol Cardiothorac Imaging. 2024. PMID: 39446043. doi:10.1148/ryct.240041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。