文献速递头颈神经MR

运动抑制采集与重建DWI可提升鼻咽癌患者图像质量:与单次激发平面回波DWI的非平面回波DWI比较

Acquisition and reconstruction with motion suppression DWI enhance image quality in nasopharyngeal carcinoma patients: Non-echo-planar DWI comparison with single-shot echo-planar DWI.
PubMed 文献 · Eur J Radiol · 2024-09-21

研究纳入90例鼻咽癌患者,比较运动抑制采集与重建(ARMS)DWI与单次激发平面回波(SS-EPI)DWI的图像质量。ARMS DWI在病灶可见性、几何变形和整体图像质量评分上均显著更高(均P<0.001),病灶检出率为100% vs SS-EPI的95.56%(P<0.043),但与T2WI融合的错配距离更小(均P<0.001);ARMS DWI的SNR和CNR较低,ADC值较高。结论认为ARMS DWI通过减少几何变形和磁敏感伪影改善图像质量,对小病灶诊断优于SS-EPI DWI。

要点

  • ARMS DWI病灶检出率100%,SS-EPI DWI为95.56%(P<0.043)。
  • ARMS DWI的SNR和CNR低于SS-EPI DWI,但ADC值更高。
  • ARMS DWI与T2WI融合错配距离小于SS-EPI DWI与T2WI(均P<0.001)。

核心结论

  • ARMS DWI通过减少几何变形和磁敏感伪影改善图像质量,对小尺寸鼻咽病灶的诊断优于SS-EPI DWI,尽管其SNR和CNR较低。

研究设计与样本

  • 共纳入90例鼻咽癌患者,行MR检查,包括ARMS DWI和SS-EPI DWI序列,b值均为0和800 s/mm²;由两名放射科医生评估病灶可见性、几何变形和整体图像质量,并比较SNR、CNR、几何变形程度和鼻咽病灶ADC值,采用Wilcoxon符号秩检验比较定量和定性参数。

关键影像表现/征象

  • ARMS DWI的病灶可见性、几何变形和整体图像质量评分均显著高于SS-EPI DWI(均P<0.001)。
  • SS-EPI DWI序列中4个小尺寸病灶不可见、4个病灶部分可见;ARMS DWI病灶检出率100%,SS-EPI为95.56%(P<0.043)。
  • ARMS DWI与T2WI融合图像的错配距离小于SS-EPI DWI与T2WI融合图像(均P<0.001)。

诊断标准与关键数值

  • ARMS DWI的SNR为114.48 ± 37.89,低于SS-EPI DWI的202.61 ± 78.84(P<0.001)。
  • ARMS DWI的CNR为1.81 ± 1.84,低于SS-EPI DWI的3.29 ± 3.71(P<0.003)。
  • ARMS DWI的ADC值为839.19 ± 138.44 × 10⁻⁶ mm²/s,高于SS-EPI DWI的788.82 ± 110.96 × 10⁻⁶ mm²/s(P<0.002)。

临床应用与阅片要点

  • ARMS DWI可减少几何变形和磁敏感伪影,有助于提高鼻咽癌小病灶的检出和与T2WI的融合配准。
  • ARMS DWI的SNR和CNR低于SS-EPI DWI,阅片时需注意图像信噪比变化对病灶显示的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the impact of application acquisition and reconstruction with motion suppression (ARMS) technology on improving the image quality of diffusion-weighted Imaging (DWI) for nasopharyngeal carcinoma (NPC), compared to single-shot echo-planar imaging (SS-EPI).

METHODS: A total of 90 patients with NPC underwent MR examination, including ARMS DWI and SS-EPI DWI sequences. Both DWI sequences were acquired with b-values 0 and 800 s/mm2. Two radiologists evaluated the visibility of the lesion, geometric distortion, and overall image quality of the two DWI sequences. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion degree, and apparent diffusion coefficient (ADC) values of the nasopharyngeal lesions were assessed and compared for two sequences. The Wilcoxon signed-rank test was used to compare the quantitative and qualitative parameters of the two sequences.

RESULTS: The lesion visibility, geometric distortion, and overall image quality scores were significantly higher in ARMS DWI (all P<0.001). Four small-sized lesions were not visible and four lesions were partially visible in the SS-EPI DWI sequence. Lesion detection rate of ARMS DWI is 100 %, while that of SS-EPI is 95.56 %, P<0.043. The mismatch distance between the fusion images of ARMS DWI and T2WI was smaller than that of SS-EPI DWI and T2WI (all P<0.001). The SNR and CNR of ARMS DWI were lower than that of SS-EPI DWI (114.48 ± 37.89 vs. 202.61 ± 78.84, P<0.001 and 1.81 ± 1.84 vs. 3.29 ± 3.71, P<0.003) while the ADC value was higher (839.19 ± 138.44 × 10-6 mm2/s vs. 788.82 ± 110.96 × 10-6 mm2/s, P<0.002).

CONCLUSION: ARMS DWI improves the image quality by reducing geometric distortion and magnetic susceptibility artifacts. ARMS DWI is superior to SS-EPI DWI for diagnosing small-sized nasopharyngeal lesions, although it has lower SNR and CNR.

来源:Eur J Radiol,查看原文。版权归原作者所有。