数字减影脊髓造影后行锥形束CT脊髓造影对检测脑脊液-静脉瘘的额外诊断价值
回顾性分析2021年8月5日至2024年8月4日连续85例符合国际头痛疾病分类第3版自发性颅内低压标准、接受侧卧位数字减影脊髓造影联合锥形束CT脊髓造影的患者,59例存在单一致病性脑脊液-静脉瘘,其中数字减影脊髓造影显示38例、锥形束CT脊髓造影显示59例,26例两种技术均未发现明确瘘;锥形束CT脊髓造影提高了脑脊液-静脉瘘的检出率,可能是有益补充。
要点
- 59例阳性病例中,数字减影脊髓造影显示38例,锥形束CT脊髓造影显示59例。
- 85例中26例两种技术均未发现明确瘘。
- 锥形束CT脊髓造影可提高脑脊液-静脉瘘的定位检出率。
核心结论
- 锥形束CT脊髓造影提高了脑脊液-静脉瘘的检出率,可能是有益补充。
研究设计与样本
- 回顾性研究,连续纳入2021年8月5日至2024年8月4日接受侧卧位数字减影脊髓造影联合锥形束CT脊髓造影的患者,最终分析85例;所有脊髓造影图像由2名神经放射科医生独立阅片;参考标准为国际头痛疾病分类第3版自发性颅内低压标准及影像学硬膜外脑脊液表现。
关键影像表现/征象
- 59例阳性病例中,数字减影脊髓造影显示瘘38例,锥形束CT脊髓造影显示瘘59例。
- 85例中26例两种技术均未发现明确瘘。
诊断标准与关键数值
- 数字减影脊髓造影在59例阳性病例中检出38例瘘。
- 锥形束CT脊髓造影在59例阳性病例中检出59例瘘。
- 85例中26例两种技术均未发现明确瘘。
临床应用与阅片要点
- 在侧卧位数字减影脊髓造影基础上加做锥形束CT脊髓造影,可提高脑脊液-静脉瘘的检出。
- 原文结论认为锥形束CT脊髓造影可能是有益补充。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: CSF-venous fistulas (CVFs) are a common cause of spontaneous intracranial hypotension. The diagnosis and precise localization of these fistulas hinges on specialized myelographic techniques, which mainly include decubitus digital subtraction myelography and decubitus CT myelography (by using either energy-integrating or photon-counting detector CT). A previous case series showed that conebeam CT myelography (CB-CTM), performed as an adjunctive tool with digital subtraction myelography, increased the detection of CVFs. Here, we sought to determine the additive yield of CB-CTM for CVF detection in a consecutive series of patients with spontaneous intracranial hypotension who underwent concurrent decubitus digital subtraction myelography and CB-CTM.
MATERIALS AND METHODS: We retrospectively searched our institutional database for all consecutive patients who underwent decubitus digital subtraction myelography with adjunctive CB-CTM between August 5, 2021 and August 5, 2024. We excluded any patients harboring extradural CSF on spine imaging, not meeting International Classification of Headache Disorders, 3rd edition criteria for spontaneous intracranial hypotension, or not having undergone technically successful CB-CTM in combination with digital subtraction myelography. All myelographic images were independently reviewed by 2 neuroradiologists. We calculated the diagnostic yield of both myelographic tests for localizing a CVF.
RESULTS: We identified 100 patients who underwent decubitus digital subtraction myelography with adjunctive conebeam CT. We excluded 15 patients based on above criteria. Fifty-nine of 85 patients had a single definitive CVF. Among positive cases, the fistula was visible on digital subtraction myelography in 38 of 59 patients and visible on CB-CTM in 59 of 59 patients. In 26 of 85 patients, no definitive fistula was identified by either technique.
CONCLUSIONS: CB-CTM increased the diagnostic yield for CVF detection and may be a useful addition to digital subtraction myelography.
引用
- Madhavan AA, Lutzen N, Cutsforth-Gregory JK, et al. Additional Diagnostic Value of Conebeam CT Myelography Performed after Digital Subtraction Myelography for Detecting CSF-Venous Fistulas. AJNR Am J Neuroradiol. 2025. PMID: 39406513. doi:10.3174/ajnr.A8535
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。