健康志愿者与胶质母细胞瘤患者中伪连续动脉自旋标记测量的脑灌注可重复性与再现性
本前瞻性研究在3T场强下评估了3D伪连续动脉自旋标记(pCASL)结合TSE-CASPR或GRASE采集在健康志愿者和胶质母细胞瘤患者中的组内重复性和组间再现性。结果显示两种采集在健康志愿者和患者中均具有高组内重复性,健康志愿者组间再现性良好至优秀;GRASE在健康志愿者中表现略优,而TSE-CASPR在肿瘤区域表现更佳且信噪比接近2倍。
要点
- 3D pCASL在健康志愿者和胶质母细胞瘤患者中均显示高组内重复性(ICC 0.96-0.98)。
- 健康志愿者组间再现性良好至优秀(ICC 0.85和0.90)。
- 在肿瘤区域,TSE-CASPR较GRASE的信噪比接近2倍。
核心结论
- 3D pCASL测量的脑灌注在健康志愿者和胶质母细胞瘤患者中具有优秀的组内重复性,在健康志愿者中具有良好至优秀的组间再现性;GRASE在健康志愿者中表现略优,而TSE-CASPR在肿瘤区域表现更佳且信噪比接近2倍。
研究设计与样本
- 前瞻性研究(NCT03922984),纳入20名健康志愿者和21例胶质母细胞瘤患者,在3T场强下比较3D pCASL结合TSE-CASPR与GRASE采集。
诊断标准与关键数值
- 组内重复性:TSE-CASPR的R²为0.88-0.95,GRASE的R²为0.93-0.96;TSE-CASPR的偏倚为-0.46至0.81 mL/100 g/min,GRASE的偏倚为-0.08至0.35 mL/100 g/min;TSE-CASPR的ICC为0.96-0.98(95%CI 0.94-0.98),GRASE的ICC为0.96-0.98(95%CI 0.92-0.99);TSE-CASPR的wsCV为6.64%-9.07%,GRASE的wsCV为5.20%-8.16%。
- 组间再现性(健康志愿者):TSE-CASPR的R²为0.71,GRASE的R²为0.82;TSE-CASPR的偏倚为-1.2 mL/100 g/min,GRASE的偏倚为-0.90 mL/100 g/min;TSE-CASPR的ICC为0.85(95%CI 0.81-0.89),GRASE的ICC为0.90(95%CI 0.87-0.93);TSE-CASPR的wsCV为13.82%,GRASE的wsCV为9.98%。
临床应用与阅片要点
- ASL测量的灌注可作为无对比剂定量影像生物标志物,有助于胶质母细胞瘤患者的管理。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Arterial spin-labeling (ASL) MRI has gained recognition as a quantitative perfusion imaging method for managing patients with brain tumors. Limited studies have so far investigated the reproducibility of ASL-derived perfusion in these patients. This study aimed to evaluate intrasession repeatability and intersession reproducibility of perfusion measurements using 3D pseudocontinuous ASL (pCASL) with TSE Cartesian acquisition with spiral profile reordering (TSE-CASPR) in healthy volunteers (HV) and patients with glioblastoma (GBM) at 3T and to compare them against 3D pCASL with gradient and spin echo (GRASE).
MATERIALS AND METHODS: This prospective study (NCT03922984) was approved by the institutional review board, and written informed consent was obtained from all subjects. HV underwent repeat pCASL evaluations 2-4 weeks apart between November 2021 and October 2022. Patients with GBM were recruited for longitudinal MRI from September 2019 to February 2023. Intrasession repeatability (HV and GBM) and intersession reproducibility (HV only) of pCASL were assessed using linear regression, Bland-Altman analyses, the intraclass correlation coefficient (ICC) with 95% CI, and within-subject coefficients of variation (wsCV).
RESULTS: Twenty HV (9 men; mean age, 25.1 [SD, 1.7] years; range, 23-30 years) and 21 patients with GBM (15 men; mean age, 59.8 [SD, 14.3] years; range, 28-81 years) were enrolled. In imaging sessions, 3D pCASL-measured perfusion with TSE-CASPR and GRASE, respectively, achieved high R 2 values (0.88-0.95; 0.93-0.96), minimal biases (-0.46-0.81; -0.08-0.35 mL/100 g/min), high ICCs [95% CI], 0.96-0.98 [0.94-0.98]; 0.96-0.98 [0.92-0.99]), and low wsCV (6.64%-9.07%; 5.20%-8.16%) in HV (n = 20) and patients with GBM (n = 21). Across imaging sessions, 3D pCASL in HV (n = 20) achieved high R 2 values (0.71; 0.82), minimal biases (-1.2; -0.90 mL/100 g/min), high ICC [95% CI] values (0.85 [0.81-0.89]; 0.90 [0.87-0.93]), and low wsCV values (13.82%; 9.98%).
CONCLUSIONS: Our study demonstrated excellent intrasession repeatability of 3D pCASL-measured cerebral perfusion in HV and patients with GBM and good-to-excellent intersession reproducibility in HV. 3D pCASL with GRASE performed slightly better than 3D pCASL with TSE-CASPR in HV; however, in patients with GBM, 3D pCASL with TSE-CASPR showed better performance in tumor regions with a nearly 2-fold higher SNR. ASL-measured perfusion could serve as a noncontrast quantitative imaging biomarker to facilitate the management of patients with GBM.
引用
- Zhou L, Udayakumar D, Wang Y, et al. Repeatability and Reproducibility of Pseudocontinuous Arterial Spin-Labeling-Measured Brain Perfusion in Healthy Volunteers and Patients with Glioblastoma. AJNR Am J Neuroradiol. 2025. PMID: 39443151. doi:10.3174/ajnr.A8551
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。