心血管磁共振半自动阈值后处理评估法洛四联症修复术后右心室容积
本研究在62例法洛四联症修复术后患者的CMR中比较半自动阈值法(SAT-50与SAT-30)与全手动描记法。SAT-30在右心室质量、容积和射血分数上与手动法无显著差异,SAT-50则低估右心室舒张末期容积指数10.4%、高估质量指数21.8%。SAT后处理时间明显短于手动法(5.5±1.7分钟 vs. 19.5±4.4分钟,p<0.001),观察者内和观察者间变异度好至优秀。
要点
- SAT-30与全手动描记法在右心室质量、容积和射血分数上无显著差异,可替代手动法。
- SAT-50会显著低估右心室舒张末期容积指数并高估质量指数,6例患者因此从扩张型变为非扩张型。
- SAT后处理时间明显短于全手动描记法(5.5±1.7分钟 vs. 19.5±4.4分钟,p<0.001)。
核心结论
- CMR SAT-30后处理是评估法洛四联症修复术后双心室容积、射血分数和质量的精确、准确且省时的方法。
研究设计与样本
- 研究论文;纳入62例法洛四联症修复术后患者的CMR;比较半自动阈值法(SAT-50和SAT-30)与全手动描记法;以主肺动脉前向血流(MPA-FF)作为右心室每搏量参考。
诊断标准与关键数值
- 与全手动描记法相比,SAT-30在右心室质量、容积和射血分数上无显著差异;SAT-50低估右心室舒张末期容积指数10.4%(平均差-11.8±6.2 ml/m2,p 0.03)并高估右心室质量指数21.8%(平均差14.2±11.9 g/m2,p 0.002);与MPA-FF相比,全手动法和SAT-30的右心室每搏量偏差分别为0.03 ml/m2和0.7 ml/m2,SAT-50低估右心室每搏量6.86 ml/m2(p<0.001)。
临床应用与阅片要点
- 在法洛四联症修复术后CMR右心室分析中,SAT-30后处理与全手动描记法结果无显著差异且耗时更短(5.5±1.7分钟 vs. 19.5±4.4分钟,p<0.001);SAT-50会低估右心室舒张末期容积指数10.4%并高估质量指数21.8%,在6例患者中导致从扩张型变为非扩张型的分类改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Cardiovascular magnetic resonance (CMR) is the gold-standard to estimate right ventricular (RV) volumes, which are key for clinical management of patients with repaired tetralogy of Fallot (rTOF). Semi-automated threshold-based methods (SAT) have been proposed for CMR post-processing as alternatives to fully manual standard tracing. We investigated the impact of SAT on RV analysis using different thresholds in rTOF patients.
METHODS: RV volumes and mass were estimated using SAT and standard fully manual tracing methods in rTOF patients. Two threshold levels were set for SAT, i.e., default 50 (SAT-50) and 30 (SAT-30). RV stroke volumes (SV) were compared to main pulmonary artery forward flow (MPA-FF). Post-processing time, intra- and interobserver variabilities were compared across methods.
RESULTS: Sixty-two CMRs of rTOF patients were analyzed. Compared to the standard fully manual tracing, no significant differences in RV mass, volumes and ejection fraction were observed using SAT-30, whereas SAT-50 significantly underestimated RV end-diastolic-volume index (EDVi) by 10.4% (mean difference of - 11.8 ± 6.2 ml/m2, p 0.03) and overestimated RV mass index by 21.8% (mean difference of 14.2 ± 11.9 g/m2, p 0.002). Compared to MPA-FF, RVSV by standard fully manual method and SAT-30 showed minor biases, respectively, 0.03 ml/m2 and 0.7 ml/m2, while SAT-50 underestimated RVSV by 6.86 ml/m2 (p < 0.001). In six patients, the degree of RV EDVi underestimation by SAT-50 determined a change of category from dilated to non-dilated RV. Intra- and interobserver variabilities were good to excellent for all methods. Post-processing duration was shorter for SAT compared to standard manual segmentation (5.5 ± 1.7 min vs. 19.5 ± 4.4 min, p < 0.001).
CONCLUSION: CMR SAT-30 post-processing is a precise, accurate and time-saving method for biventricular assessment of volumes, ejection fraction and mass in rTOF.
引用
- Tondi L, Figliozzi S, Boveri S, et al. Cardiovascular magnetic resonance semi-automated threshold-based post-processing of right ventricular volumes in repaired tetralogy of Fallot. Radiol Med. 2024. PMID: 39476274. doi:10.1007/s11547-024-01908-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。