高分辨率头部CTA:光子计数探测器CT与能量积分探测器CT图像质量的前瞻性患者研究

High-Resolution Head CTA: A Prospective Patient Study Comparing Image Quality of Photon-Counting Detector CT and Energy-Integrating Detector CT.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-10-03

前瞻性纳入28例成人患者,同一天行EID-CT和PCD-CT头部CTA,比较0.6 mm匹配SR重建及PCD 0.2 mm UHR联合CNN去噪的图像质量与诊断信心。PCD-SR和PCD-UHR-CNN整体图像质量及动脉节段显示均优于EID-SR,PCD诊断信心显著更高,两组CT剂量指数相似。

要点

  • PCD-UHR-CNN与EID-SR整体图像质量评分:R1为4.0±0.0对3.0±0.0,R2为4.9±0.3对3.0±0.0,均P<.001。
  • PCD-SR动脉节段显示Likert评分优于EID-SR:R1为1.0-1.3,R2为1.0-1.8。
  • PCD-UHR-CNN诊断信心显著高于EID-SR:R1为93.0±5.8对78.2±9.3,R2为88.6±5.9对70.4±5.0,均P<.001。

核心结论

  • 与EID-CT相比,PCD-CT在匹配重建条件下即可提高头部CTA图像质量,PCD-UHR联合CNN去噪时提升幅度更大。

研究设计与样本

  • 前瞻性患者研究,28例成人患者先后行EID-CT和PCD-CT头部CTA;PCD和EID均以0.6 mm匹配标准分辨率(SR)重建,PCD另以0.2 mm最薄层厚和最锐利卷积核重建(UHR)并行深度卷积神经网络(CNN)去噪。

诊断标准与关键数值

  • 整体图像质量采用1(最差)至5(最佳)评分。
  • 侧边比较采用Likert评分,-2(显著较差)至2(显著较优),用于多个图像质量特征及特定动脉节段显示。
  • 诊断信心采用0-100评分,针对存在的特定动脉表现比较PCD与EID。
  • PCD-UHR-CNN与EID-SR整体图像质量:R1为4.0±0.0对3.0±0.0,R2为4.9±0.3对3.0±0.0,均P<.001。
  • PCD-SR动脉节段显示Likert评分:R1为1.0-1.3,R2为1.0-1.8;PCD-UHR-CNN对EID-SR:R1为0.9-1.4,R2为1.9-2.0。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Photon-counting detector CT (PCD-CT) is now clinically available and offers ultra-high-resolution (UHR) imaging. Our purpose was to prospectively evaluate the relative image quality and impact on diagnostic confidence of head CTA images acquired by using a PCD-CT compared with an energy-integrating detector CT (EID-CT).

MATERIALS AND METHODS: Adult patients undergoing head CTA on EID-CT also underwent a PCD-CT research examination. For both CT examinations, images were reconstructed at 0.6 mm by using a matched standard resolution (SR) kernel. Additionally, PCD-CT images were reconstructed at the thinnest section thickness of 0.2 mm (UHR) with the sharpest kernel, and denoised with a deep convolutional neural network (CNN) algorithm (PCD-UHR-CNN). Two readers (R1, R2) independently evaluated image quality in randomized, blinded fashion in 2 sessions, PCD-SR versus EID-SR and PCD-UHR-CNN versus EID-SR. The readers rated overall image quality (1 [worst] to 5 [best]) and provided a Likert comparison score (-2 [significantly inferior] to 2 [significantly superior]) for the 2 series when compared side-by-side for several image quality features, including visualization of specific arterial segments. Diagnostic confidence (0-100) was rated for PCD versus EID for specific arterial findings, if present.

RESULTS: Twenty-eight adult patients were enrolled. The volume CT dose index was similar (EID: 37.1 ± 4.7 mGy; PCD: 36.1 ± 4.0 mGy). Overall image quality for PCD-SR and PCD-UHR-CNN was higher than EID-SR (eg, PCD-UHR-CNN versus EID-SR: 4.0 ± 0.0 versus 3.0 ± 0.0 (R1), 4.9 ± 0.3 versus 3.0 ± 0.0 (R2); all P values < .001). For depiction of arterial segments, PCD-SR was preferred over EID-SR (R1: 1.0-1.3; R2: 1.0-1.8), and PCD-UHR-CNN over EID-SR (R1: 0.9-1.4; R2: 1.9-2.0). Diagnostic confidence of arterial findings for PCD-SR and PCD-UHR-CNN was significantly higher than EID-SR: eg, PCD-UHR-CNN versus EID-SR: 93.0 ± 5.8 versus 78.2 ± 9.3 (R1), 88.6 ± 5.9 versus 70.4 ± 5.0 (R2); all P values < .001.

CONCLUSIONS: PCD-CT provides improved image quality for head CTA images compared with EID-CT, both when PCD and EID reconstructions are matched, and to an even greater extent when PCD-UHR reconstruction is combined with a CNN denoising algorithm.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Diehn FE, Zhou Z, Thorne JE, et al. High-Resolution Head CTA: A Prospective Patient Study Comparing Image Quality of Photon-Counting Detector CT and Energy-Integrating Detector CT. AJNR Am J Neuroradiol. 2024. PMID: 39237360. doi:10.3174/ajnr.A8342

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。