超声造影在股骨头灌注评估中的作用:一项先导研究
该先导研究前瞻性纳入10例婴儿(7例发育性髋关节发育不良、3例化脓性髋关节炎),对20个髋关节行超声造影检查,以灌注面积比和微泡缺损区象限位置评估股骨头灌注。病例组灌注面积比较对照组显著降低(49.79% vs 100.00%,p<0.05),基于介入前检查调整髋外展角后介入后灌注面积比显著升高(37.63% vs 60.24%,p<0.05),随访较基线升高(45.61% vs 76.07%,p<0.05);观察者间与观察者内重复性极佳(组内相关系数均为0.97)。
要点
- 病例组灌注面积比较对照组显著降低(49.79% vs 100.00%,p<0.05)。
- 微泡缺损区平均累及2个象限,以第3象限(30%)和第4象限(32%)为主。
- 基于介入前超声造影调整髋外展角后,灌注面积比显著升高(37.63% vs 60.24%,p<0.05)。
核心结论
- 超声造影可定量检测发育性髋关节发育不良和化脓性髋关节炎婴儿的股骨头灌注,重复性高,对基线、介入中及随访评估有潜在价值。
研究设计与样本
- 前瞻性先导研究,纳入10例婴儿(7例发育性髋关节发育不良、3例化脓性髋关节炎),双侧髋关节交替行超声造影检查,共20个髋关节分为病例组(n=11)和对照组(n=9);对需要干预的发育性髋关节发育不良婴儿行介入前和介入后检查。
关键影像表现/征象
- 病例组灌注面积比较对照组显著降低(49.79% vs 100.00%,p<0.05)。
- 微泡缺损区平均累及2个象限,主要位于第3象限(30%)和第4象限(32%)。
诊断标准与关键数值
- 以灌注面积比和微泡缺损区的象限位置评估股骨头灌注。
- 病例组灌注面积比49.79% vs 对照组100.00%,p<0.05。
- 介入后灌注面积比37.63% vs 介入前60.24%,p<0.05。
- 随访灌注面积比45.61% vs 基线76.07%,p<0.05。
- 灌注面积比测量的观察者间和观察者内组内相关系数均为0.97。
临床应用与阅片要点
- 超声造影可用于发育性髋关节发育不良和化脓性髋关节炎婴儿股骨头灌注的基线、介入中及随访定量评估。
- 灌注面积比测量重复性高(组内相关系数均为0.97),适合用于系列监测。
- 微泡缺损区主要位于第3和第4象限,阅片时可重点观察这些区域。
- 基于介入前超声造影调整髋外展角后灌注面积比显著升高(37.63% vs 60.24%,p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We explored the value of contrast-enhanced ultrasound (CEUS) in evaluating femoral head (FH) perfusion, guiding interventions and follow-up for infants with developmental dysplasia of the hip (DDH) and septic arthritis of the hip (SAH). The aim was to provide robust evidence for clinical assessment.
METHODS: Ten infants, including 7 with DDH and 3 with SAH, were prospectively enrolled, with their bilateral hips alternately scanned during the CEUS exams. Twenty hips were classified into the case group (n = 11) and the control group (n = 9). Pre- and post-interventional studies were performed in DDH infants requiring interventions. FH perfusion was assessed by the perfusion area ratio (PAR) and quadrant location of microbubble-defect regions.
RESULTS: In the case group, 25 CEUS studies were conducted, including 11 baseline, 7 follow-up and 7 post-intervention studies. The PAR significantly decreased in the case group (49.79% vs. 100.00%, p < 0.05). The microbubble-defect regions averagely affected 2 quadrants, primarily quadrat No. 3 (30%) and No. 4 (32%). Seven hip abduction angle adjustments were made based on pre-interventional studies, resulting in a significant increase in PAR in post-interventional studies (37.63% vs. 60.24%, p < 0.05). PAR increased in follow-up studies compared to baseline values (45.61% vs. 76.07%, p < 0.05). The inter- and intra-observer reproducibility of PAR measurements were excellent (intraclass correlation coefficient, both 0.97).
CONCLUSION: CEUS proves to be a promising technique for quantitatively detecting FH perfusion in DDH and SAH infants with high reproducibility. It is valuable for baseline, intra-intervention and follow-up studies, aiming in clinical conditions and therapeutic effect evaluation.
引用
- Cheng C, Shen X, Sun J, et al. The Role of Contrast-enhanced Ultrasound in the Femoral Head Perfusion Evaluation: A Pilot Study. Ultrasound Med Biol. 2024. PMID: 39278802. doi:10.1016/j.ultrasmedbio.2024.08.005