儿童颅面部影像:超短回波时间骨选择性MRI与CT的对比研究
本研究纳入12例8至18岁患儿,在3T下采用双射频双回波超短回波时间(UTE)MRI序列生成亮骨图像,并与CT比较。UTE MRI亮骨图像骨对比度高、软组织抑制好、窦腔气体分离清晰;MRI与CT颅骨二值掩模的Dice相似系数中位数0.81±0.10,95百分位Hausdorff距离中位数1.87±0.32 mm;6项颅骨测量距离的Lin一致性相关系数ρc为0.90至0.99,平均绝对差小于2 mm。结论认为UTE MRI序列用于儿童颅面部成像的临床可行性得到验证,在分辨薄骨结构和颅骨测量方面与CT具有良好一致性。
要点
- UTE MRI亮骨图像可清晰显示薄骨结构,软组织抑制良好,窦腔处骨与气体分离清楚。
- MRI与CT颅骨掩模Dice相似系数中位数0.81±0.10,HD95中位数1.87±0.32 mm。
- 6项颅骨测量距离MRI与CT一致性良好(ρc 0.90至0.99),平均绝对差小于2 mm。
核心结论
- 在12例患儿中验证了UTE MRI序列用于颅面部成像的临床可行性,其在分辨薄骨结构和颅骨测量方面与CT具有良好一致性。
研究设计与样本
- 研究纳入12例患儿(6例女性,年龄8至18岁),在3T下采用双射频双回波UTE MRI序列扫描,以加权最小二乘共轭梯度法生成亮骨图像,并与CT比较颅骨掩模重叠度和颅骨测量距离。
关键影像表现/征象
- UTE MRI亮骨图像骨对比度高,软组织信号被抑制,窦腔处骨与气体分离清晰。
- MRI与CT颅骨二值掩模的Dice相似系数中位数为0.81±0.10,95百分位Hausdorff距离中位数为1.87±0.32 mm。
- 6项颅骨测量距离的Lin一致性相关系数ρc为0.90至0.99,平均绝对差小于2 mm。
诊断标准与关键数值
- 以Dice相似系数和95百分位Hausdorff距离(HD95)定量评价MRI与CT颅骨掩模的相似性,DSC中位数0.81±0.10,HD95中位数1.87±0.32 mm。
- 以Lin一致性相关系数评价MRI与CT颅骨测量距离的一致性,ρc为0.90至0.99,平均绝对差小于2 mm。
临床应用与阅片要点
- 儿童颅面部薄骨结构评估可参考UTE MRI亮骨图像,其与CT在颅骨掩模重叠和颅骨测量上一致性良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The emergence of low-dose protocols for CT imaging has mitigated pediatric radiation exposure, yet ionizing radiation remains a concern for children with complex craniofacial conditions requiring repeated radiologic monitoring. In this work, the clinical feasibility of an ultrashort echo time (UTE) MRI sequence was investigated in pediatric patients.
MATERIALS AND METHODS: Twelve pediatric patients (6 female, age range 8 to 18 years) with various imaging conditions were scanned at 3T using a dual-radiofrequency, dual-echo UTE MRI sequence. Bright-bone images were generated using a weighted least-squares conjugate gradient method to enhance bone specificity. The overlap of the binary skull masks was quantified using the Dice similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD95) to evaluate the similarity between MRI and CT. To assess the anatomic accuracy of 3D skull reconstructions, six craniometric distances were recorded and the agreement between MRI- and CT-derived measurements was evaluated using Lin's concordance correlation coefficient (ρc).
RESULTS: The bright-bone images from UTE MRI demonstrated high bone-contrast, suppression of soft tissue, and separation from air at the sinuses. The DSC and HD95 between MRI and CT had medians of 0.81 ± 0.10 and 1.87 ± 0.32 mm, respectively. There was good agreement between MRI and CT for all craniometric distances (ρc ranging from 0.90 to 0.99) with a mean absolute difference in measurements of < 2 mm.
CONCLUSION: The clinical feasibility of the UTE MRI sequence for craniofacial imaging was demonstrated in a cohort of pediatric patients, showing good agreement with CT in resolving thin bone structures and craniometry.
引用
- Kamona N, Ng JJ, Kim Y, et al. Craniofacial Imaging of Pediatric Patients by Ultrashort Echo-Time Bone-Selective MRI in Comparison to CT. Acad Radiol. 2024. PMID: 39242296. doi:10.1016/j.acra.2024.08.053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。