文献速递骨肌US

利用剪切波弹性成像量化间歇性最大等长收缩后跖屈肌的主动与被动刚度

Quantifying Active and Passive Stiffness in Plantar Flexor Muscles Following Intermittent Maximal Isometric Contractions Using Shear Wave Elastography.
PubMed 文献 · Ultrasound Med Biol · 2024-09-28

健康队列(n=12)完成60次最大等长收缩后,主动刚度、跖屈肌峰值力矩、力矩发展速率及腓肠肌内侧头表面肌电活动下降(p<0.001),峰值力矩下降与腓肠肌内侧头主动刚度下降相关(r=0.6;p<0.05),被动踝关节活动时跖屈肌-肌腱复合体刚度及腓肠肌内侧头20°剪切模量亦下降(p<0.001)。

要点

  • 等长疲劳运动后跖屈肌主动刚度与被动刚度均下降。
  • 腓肠肌内侧头主动刚度下降与峰值力矩下降相关(r=0.6)。
  • 剪切波弹性成像可用于量化疲劳前后肌肉主被动刚度变化。

核心结论

  • 等长疲劳运动改变收缩成分与弹性成分的力学特性,被动与主动刚度下降可能对运动员具有重要性,因为这些变化可能增加损伤风险。

研究设计与样本

  • 健康队列研究,样本量n=12(年龄27.3±5.5岁;BMI 24.4±2.35 kg/m²),受试者使用测力计完成60次等长收缩、每次持续4 s、间隔1 s休息,疲劳方案前后进行多项测量,以剪切波弹性成像测量腓肠肌内侧头主动与被动刚度,以测力计评估跖屈肌峰值力矩与力矩发展速率,以表面肌电记录踝部肌肉活动。

关键影像表现/征象

  • 疲劳方案后,被动踝关节活动时跖屈肌-肌腱复合体刚度下降(p<0.001)。
  • 疲劳方案后,腓肠肌内侧头在20°时的剪切模量下降(p<0.001)。
  • 疲劳方案后,腓肠肌内侧头主动刚度下降(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed: (i) to investigate the impact of fatigue, triggered by maximal isometric contraction exercises, on the active and passive stiffness of plantar flexors (PF), and (ii) to examine the relationship between changes in mechanical parameters and neuromuscular alterations after fatigue.

METHODS: A healthy cohort (n = 12; age = 27.3 ± 5.5 y; BMI = 24.4 ± 2.35 kg/m²) was instructed to perform 60 isometric contractions, each lasting 4 s with a 1-s rest interval, using an ergometer. Several measures were taken before and after the fatigue protocol. First, the stiffness of the PF-tendon complex (PFC) was quantified during passive ankle mobilization both during and after the fatigue protocol using the ergometer. Additionally, from shear wave elastography, the active and passive stiffness of the gastrocnemius medialis (GM) were measured during passive ankle mobilization and isometric maximal voluntary contraction (MVC), respectively. Finally, the peak torque and the rate of torque development (RFD) of PF were assessed during the MVC using the ergometer. Ankle muscle activities (surface electromyograph [SEMG]) were recorded during all evaluations using electromyography.

RESULTS: After the fatigue protocol, the results revealed a decline in active stiffness, peak torque of PF, RFD and SEMG activity of the GM (p < 0.001). Furthermore, significant correlation was identified between the decrease of the peak torque of PF and the active stiffness of the GM (r = 0.6; p < 0.05). A decrease in the PFC stiffness (p < 0.001) and a decrease in the shear modulus of the GM at 20° (p < 0.001) were also observed.

CONCLUSION: Isometric fatiguing exercises modify the mechanical properties of both the contractile and elastic components. Notably, decreases in both passive and active stiffness may be critical for athletes, as these changes could potentially increase the risk of injury.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Vincent L, Zidi M, Portero P, et al. Quantifying Active and Passive Stiffness in Plantar Flexor Muscles Following Intermittent Maximal Isometric Contractions Using Shear Wave Elastography. Ultrasound Med Biol. 2024. PMID: 39343628. doi:10.1016/j.ultrasmedbio.2024.09.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。