文献速递骨肌USCT

超声与双能CT诊断膝关节痛风性关节炎的一致性:一项回顾性观察研究

Concordance of Ultrasound and Dual-Energy CT in Diagnosing Gouty Arthritis in the Knee Joint: A Retrospective Observational Study.
PubMed 文献 · Acad Radiol · 2024-09-07

回顾性分析167例痛风患者176个膝关节的超声与双能CT图像,按关节内、前、后、内、外侧五区记录单钠尿酸盐结晶沉积。超声总体阳性率高于双能CT(81.1% vs 72.2%),一致性差(κ=0.177);内侧和外侧区一致性高(κ=0.651、0.705),关节内和前区一致性一般。

要点

  • 超声总体阳性率81.1%高于双能CT的72.2%,两者一致性差(κ=0.177)。
  • 双能CT对高回声或强回声痛风石检出率高于低回声或等回声(84.3%和90.9% vs 55.1%和27.8%)。
  • 内侧和外侧区超声与双能CT一致性高(κ=0.651、0.705),关节内和前区一致性一般(κ=0.316、0.346)。

核心结论

  • 超声和双能CT均是检测膝关节痛风单钠尿酸盐沉积的有效方法,但两者一致性因解剖位置而异,临床评估应根据具体解剖位置进行选择。
  • 双能CT在评估关节内单钠尿酸盐沉积方面具有优势,而超声对早期散在单钠尿酸盐沉积的检测更敏感。

研究设计与样本

  • 回顾性观察研究,纳入2022年2月至2023年12月青岛大学附属医院痛风专病门诊诊断为痛风的167例患者共176个膝关节。
  • 对膝关节超声和双能CT图像进行回顾性分析,将膝关节分为关节内、前、后、内、外侧五个解剖区域,记录单钠尿酸盐结晶沉积位置。
  • 痛风石按回声特征分为低回声、等回声、高回声或强回声;采用Kappa检验评估两种检查方法在不同区域的一致性,McNemar卡方检验进行差异分析,卡方检验评估双能CT对不同回声痛风石的检出率差异,Pearson相关系数评估单钠尿酸盐沉积体积与临床相关指标的相关性。

关键影像表现/征象

  • 关节内超声征象以双轨征最常见(61.4%)。
  • 关节外区域单钠尿酸盐结晶常沉积于腘窝沟区域及其周围(超声:52.3%;双能CT:60.0%)。
  • 超声检出聚集物的54个关节中,双能CT发现相应单钠尿酸盐沉积者7个;超声检出双轨征的108个关节中,双能CT发现相应沉积者15个。
  • 高回声或强回声痛风石在双能CT上的检出率高于低回声或等回声痛风石(分别为84.3%和90.9% vs 55.1%和27.8%)。

诊断标准与关键数值

  • 超声对单钠尿酸盐沉积的总体阳性率高于双能CT(81.1% vs 72.2%),两者一致性差(κ=0.177)。
  • 内侧区超声与双能CT一致性高(κ=0.651),差异无统计学意义;外侧区一致性高(κ=0.705),差异无统计学意义。
  • 关节内区一致性一般(κ=0.316),前区一致性一般(κ=0.346),差异均有统计学意义。
  • 仅评估有痛风石的病例时,内侧、外侧和前区超声与双能CT一致性分别为κ=0.633、0.712和0.400,差异均有统计学意义;关节内区一致性降低(κ=0.237),差异有统计学意义。

临床应用与阅片要点

  • 超声和双能CT均可用于检测膝关节痛风单钠尿酸盐沉积,阅片时应结合具体解剖区域判读两者结果。
  • 双能CT对关节内单钠尿酸盐沉积的评估具有优势,超声对早期散在单钠尿酸盐沉积的检测更敏感。
  • 高回声或强回声痛风石在双能CT上更易检出,低回声或等回声痛风石在双能CT上检出率较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To assess the consistency between ultrasound and dual-energy computed tomography (DECT) for the diagnosis of gout in the knee joint.

MATERIALS AND METHODS: The ultrasound and DECT images of 176 knee joints from 167 patients diagnosed with gout at the Gout Specialty Clinic of Qingdao University Affiliated Hospital from February 2022 to December 2023 were retrospectively analyzed. The knee joint was segmented into five anatomical regions: intra-articular, anterior, posterior, medial, and lateral. The location of monosodium urate (MSU) crystal deposition was recorded. Tophi were classified as hypoechogenic, isoechogenic, hyperechogenic, or strongly echogenic. The Kappa test was used to assess the consistency between the two examination methods in different regions of the knee joint. The McNemar chi-square test was utilized to conduct a differential analysis between the DECT and ultrasound results. The chi-square test was used to assess differences in the rate of tophi detection with different echogenicities by DECT. Pearson's correlation coefficient was used to assess the correlation between MSU crystal deposition volume and clinically relevant indicators.

RESULTS: Double contour (61.4%) was the most common intra-articular ultrasound sign. In the extra-articular region, MSU crystals were commonly deposited in and around the popliteal groove region (ultrasound: 52.3%; DECT: 60.0%). Corresponding MSU deposits on DECT were found in 7 of 54 joints with aggregates detected on ultrasound, and in 15 of 108 joints with DC. Tophi with hyperechogenicity or strong echogenicity were more likely to be detected on DECT than those with hypoechoic or isoechoic features (84.3% and 90.9% vs. 55.1% and 27.8%, respectively). For the assessment of MSU deposits, ultrasound showed an overall higher positive rate than DECT (81.1% vs. 72.2%), with poor consistency between the two examinations (κ = 0.177). In distinct anatomical regions, ultrasound and DECT showed high consistency in the medial (κ = 0.651) and lateral (κ = 0.705) views, with no significant difference. The intra-articular (κ = 0.316) and anterior (κ = 0.346) regions exhibited only fair consistency, with statistically significant diagnostic differences. When exclusively assessing cases with tophi, ultrasound and DECT demonstrated similar consistency in the medial, lateral and anterior views (κ = 0.633, 0.712, and 0.400, respectively), with statistically significant differences. In the intra-articular region, the consistency was reduced (κ = 0.237), and the differences were statistically significant.

CONCLUSION: Ultrasound and DECT are effective methods to detect MSU deposition in gout of the knee. However, the consistency between the two techniques varies in different anatomical locations. Clinical assessment should be tailored based on the specific anatomical position. DECT is advantageous for the evaluation of intra-articular MSU deposits, while ultrasound is more sensitive for the early detection of scattered MSU deposits.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yan M, Du M, Yu T, et al. Concordance of Ultrasound and Dual-Energy CT in Diagnosing Gouty Arthritis in the Knee Joint: A Retrospective Observational Study. Acad Radiol. 2024. PMID: 39245598. doi:10.1016/j.acra.2024.08.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。