手指滑膜-附着点复合体的超声解剖学

Sonoanatomy of the Finger Synovio-Entheseal Complexes.
PubMed 文献 · Ultrasound Med Biol · 2024-09-16

该超声与解剖学研究在新鲜冷冻尸体手上评估伸指肌腱中央束附着点(CSET)的超声识别可靠性及与大体解剖测量的一致性,并在人工建立的近端指间关节滑膜炎模型中观察其识别变化。结果显示组内和组间信度良好至优秀(ICC 0.93 和 0.89–0.92),超声测量仅略小于解剖测量(均值差 -0.039 mm),滑膜炎模型前后测量差异无统计学意义。

要点

  • 超声识别伸指肌腱中央束附着点具有良好至优秀的组内和组间信度(ICC 0.93 和 0.89–0.92)。
  • 超声测量与大体解剖测量一致性良好,超声测值仅略小(均值差 -0.039 mm)。
  • 实验性近端指间关节滑膜炎模型未干扰超声对中央束附着点的识别。

核心结论

  • 超声识别伸指肌腱中央束附着点具有高多观察者信度并与大体解剖一致,可将其与近端指间关节囊组织区分,且实验性近端指间关节滑膜炎模型不干扰其识别。

研究设计与样本

  • 超声与解剖学研究,由4名风湿科超声医师盲法独立测量8只新鲜冷冻尸体手第2至第5指中央束附着点厚度两轮,并与解剖学家测量对比;另在另一尸体手近端指间关节建立人工滑膜炎模型,于关节腔内超声引导下注射材料前后测量中央束附着点厚度。

关键影像表现/征象

  • 超声可识别伸指肌腱中央束附着点并将其与近端指间关节囊组织区分。
  • 实验性近端指间关节滑膜炎模型建立前后,超声测量的中央束附着点厚度差异无统计学意义。

诊断标准与关键数值

  • 组内信度ICC为0.93,组间信度ICC为0.89–0.92。
  • 超声与解剖测量均值差为-0.039 mm(超声测值仅略小于解剖测值)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The objectives of this ultrasound and anatomical study were: (1) To evaluate the reliability of ultrasound identification of the enthesis of the central slip of the extensor digitorum tendon (CSET) using cadaver specimens; (2) To assess the concordance of the measurement of the CSET thickness by ultrasound and gross anatomy; (3) To evaluate the variation in ultrasound identification of the CSET enthesis in a cadaveric experimental model of PIP synovitis.

METHODS: Four rheumatologist ultrasonographers blindly and independently measured by ultrasound the CSET enthesis thickness in the second to fifth fingers of 8 hands from fresh-frozen human cadavers in two rounds. These fingers were dissected and the thickness of the CSET measured by the anatomist. In addition, an artificial synovitis was created in the proximal interphalangeal (PIP) joints of a different cadaveric hand. The ultrasonographic CSET enthesis thickness was measured by the four investigators before and after intra-articular ultrasound guided injection of material.

RESULTS: Intra- and inter-observer reliability of CSET enthesis thickness measurement were good to excellent (ICC 0.93 for intra-observer agreement and 0.89-0.92 for inter-observer agreement). Ultrasound measurements were consistent and only slightly smaller than the anatomical ones (µ = -0.039 mm). The differences between the measurements of CSET enthesis thickness before and after the synovitis model were not statistically significant.

CONCLUSION: Ultrasound demonstrated high multiobserver reliability and agreement with gross anatomy in identifying the CSET enthesis and discriminated it from the capsular tissue of the PIP. Furthermore, an experimental model of PIP synovitis did not interfere with its identification.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Naredo E, Uson J, Olivas-Vergara O, et al. Sonoanatomy of the Finger Synovio-Entheseal Complexes. Ultrasound Med Biol. 2024. PMID: 39289117. doi:10.1016/j.ultrasmedbio.2024.08.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。