FOCUS MUSE与单次激发回波平面成像在甲状腺相关眼病扩散加权成像评估中的前瞻性比较
前瞻性纳入39例甲状腺相关眼病患者与26例健康对照,比较FOCUS MUSE与单次激发EPI扩散加权成像评估眼外肌的图像质量与诊断活动期甲状腺相关眼病的效能;FOCUS MUSE图像质量评分更高、活动期鉴别AUC 0.925优于单次激发EPI的0.779。
要点
- FOCUS MUSE DWI图像质量评分显著高于单次激发EPI(P<0.001)。
- FOCUS MUSE鉴别活动期与静止期甲状腺相关眼病AUC 0.925,优于单次激发EPI的0.779(P=0.007)。
- 两种DWI上活动期甲状腺相关眼病眼外肌ADC均高于静止期与健康对照(P<0.001)。
核心结论
- FOCUS MUSE DWI较单次激发EPI DWI提供更好的眼外肌评估图像,诊断活动期甲状腺相关眼病表现更优,有助于甲状腺相关眼病的DWI评估。
研究设计与样本
- 前瞻性研究,纳入39例甲状腺相关眼病患者(男18例,年龄48.3±13.3岁)与26例健康对照(男9例,年龄43.0±18.5岁),比较单次激发EPI与FOCUS MUSE两种DWI。
诊断标准与关键数值
- 两名放射科医师采用4分Likert量表评分视觉图像质量;FOCUS MUSE较单次激发EPI图像质量评分显著更高(P<0.001),外侧直肌与内侧直肌SNR、CNR更高(P<0.05)。
临床应用与阅片要点
- 两种DWI上活动期甲状腺相关眼病ADC均高于静止期与健康对照(P<0.001),静止期与健康对照间ADC无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO).
MATERIALS AND METHODS: SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation.
RESULTS: Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC: 0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001).
CONCLUSION: FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
引用
- Wang Y, Cui Y, Dai J, et al. Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy. Korean J Radiol. 2024. PMID: 39344548. doi:10.3348/kjr.2024.0177
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。