文献速递乳腺MR

表观扩散系数(ADC)的可重复性与诊断准确性评价及增强前后采集和不同b值应用的潜在意义

Evaluation of apparent diffusion coefficient (ADC) with regards to reproducibility and diagnostic accuracy as well as possible significance of pre - and post - contrast acquisition and employment of different b values.
PubMed 文献 · Eur J Radiol · 2024-09-13

本研究为单中心横断面回顾性研究,纳入89例患者91个经组织学验证的可疑乳腺病灶,在3T乳腺MRI中于增强前后采集多b值DWI,比较b值0/800与50/800的ADC值及诊断准确性。结果显示增强后ADC值显著低于增强前,两b值组合及增强前后ROC曲线下面积在0.834至0.877之间且无显著差异,读者间一致性近乎完美。

要点

  • 增强后ADC值较增强前略低,b值0/800与50/800组合均如此。
  • b值0/800与50/800及增强前后诊断效能无显著差异,AUC 0.834–0.877。
  • 读者间一致性近乎完美,ICC 0.853–0.939,Bland-Altman未见系统差异。

核心结论

  • 采集b值0/800及增强后ADC值略低,该效应不降低诊断效能,但在医学决策采用明确截断值时可能相关。

研究设计与样本

  • IRB批准的单中心横断面回顾性研究,纳入89例患者91个经组织学验证的可疑病灶,采用3T乳腺MRI,DWI序列于增强前后采集多b值,ADC图经在线单指数拟合计算b值0/800与50/800,两名独立读者分次判读。

诊断标准与关键数值

  • 增强后ADC均值范围1.28×10⁻³ mm²/s至1.30×10⁻³ mm²/s,显著低于增强前均值范围1.32×10⁻³ mm²/s至1.37×10⁻³ mm²/s(P<0.05),b值0/800与50/800组合均如此;读者间ICC范围0.853至0.939;ROC曲线下面积范围0.834至0.877,b值0/800与50/800之间及增强前后之间差异均无统计学意义(P>0.05)。

临床应用与阅片要点

  • 作者指出增强后及b值0/800采集时ADC值略低,该效应不降低诊断效能,但在医学决策采用明确截断值时可能相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ongoing efforts are focusing on optimizing diffusion-weighted imaging (DWI) as an essential part of breast MRI protocol. Our study aimed to evaluate the effect of contrast media (CM) on the apparent diffusion coefficients (ADC) acquired following current recommendations.

PATIENT AND METHODS: Patients who underwent 3 T breast MRI with a histologically verified suspicious lesion were included in this IRB-approved, single-center, cross-sectional retrospective study. Breast MRI protocol included a DWI sequence with multiple b-values, which was acquired before and after CM administration. ADC maps were calculated by in-line monoexponential fitting with b-values 0 /800 and 50/800. Two independent readers (R1, R2) reviewed the images in separate sessions for b values 0/800 and 50/800, pre- and post-CM. Bland Altmann plots as well as intraclass correlation coefficients (ICCs) for inter-reader agreement, different b-values, and pre- and post-CM were calculated. Diagnostic accuracy was evaluated and compared by calculating the area under the receiver operating characteristics curve (AUC).

RESULTS: 91 lesions in 89 patients were examined (mean age 50.7 years, standard deviation 13.9). ADC values were significantly (P<0.05) lower post-CM (mean ranging from 1.28 x10-3 mm2/s to 1.30 x10-3 mm2/s) compared to pre-CM (mean ranging from 1.32 x10-3 mm2/s to 1.37 x10-3 mm2/s) for both b-values combinations (0/800 and 50/800 s/mm2). We found an almost perfect inter-reader agreement pre-/post-CM with b values 0/800 and 50/800 (ICC ranging from 0.853 to 0.939). Bland Altman plot demonstrated no systematic difference between readers. ROC analysis revealed good diagnostic performance without significant differences (P>0.05) between b values 0/800 and 50/800 s/mm2 as well as pre- and post-CM with areas under the ROC curve between 0.834 and 0.877.

CONCLUSION: ADC values are slightly lower when acquiring b values 0/800 and post-CM. This effect does not reduce the diagnostic performance but may be relevant in case of definite cut-offs in medical decision making.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Varga R, Fueger BJ, Ferrara F, et al. Evaluation of apparent diffusion coefficient (ADC) with regards to reproducibility and diagnostic accuracy as well as possible significance of pre - and post - contrast acquisition and employment of different b values. Eur J Radiol. 2024. PMID: 39303393. doi:10.1016/j.ejrad.2024.111730

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。